COOLZY R290 Personal Air Conditioner User Manual

June 8, 2024
COOLZY

COOLZY R290 Personal Air Conditioner

COOLZY R290 Personal Air Conditioner

QUICK START GUIDE AND WARRANTY

| This product contains a small amount of R290 refrigerant with negligible global warming impact. The refrigerant is flammable. Read the safety manual first!
Avoid using this product in a wet environment. Ensure that anyone using this product is aware of normal safety precautions for household electric appliances.
---|---

PARTS

Parts

Indicator Panel

Indicator Panel

REMOTE

| Cooling
---|---
| Fan
| Sleeping
| Timer ON/OF
| Temperature
| Automatic air flow speed
| High speed
| Medium speed
| Low speed

Remote

Microclimate temperature setting

The thermostat turns off the compressor if the temperature of the air returning to the air conditioner is below the set temperature. Press ▲ to increase or ▼ to reduce the set temperature. If the room temperature is lower than the set temperature, the compressor will stop. The temperature of the cool air is dependent on the environment temperature and humidity, usually 8 to 14 degrees less than the ambient temperature.

Sleep key

When this key is pressed, the air flow of the unit changes into sleep mode (low speed).

  1. Press “SLEEP” to set sleep function. Press again to cancel sleep function.
  2. The temperature will increase by 0.5 °C after half an hour and 2 °C after 2 hours.
  3. When you turn off the unit, the sleep function will be cancelled automatically.

Timer key

TIMER OFF: The timer is used to turn off the unit automatically after the setting time is over.

  1. Press the “TIMER” key to set the number of hours of desired operating time.
  2. Once the set time has come to an end, the unit will turn off automatically.
  3. Press the “POWER” key before the time out, the setting time will be cancelled and the unit will turn off.

Auto key

Automatic fan speed. When the ambient temperature is 2 or more degrees higher than the set room temperature, the unit will run at high fan speed. It will automatically switch to medium and low when the ambient temperature gets closer to the set temperature.

SETUP

IMPORTANT
Always keep Coolzy upright. It may have been stored or transported on it’s side or laid flat by mistake, so please stand it upright for at least 12 hours before plugging it into power and turning it on. Failing to do so may damage the unit.

  1. After removing Coolzy from the box, place it in an upright position.

  2. Remove the cable from the drawer at the back of the unit and insert the plug into a wall outlet. Make sure you push the drawer fully back in so it is flush with the back panel. Coolzy will make a “beep” noise when plugged into power.

  3. Open the warm air deflector fully. This will turn on the unit and the compressor will start.
    • Drape a curtain as shown to exclude light when sleeping.
    Setup

  4. Open the cold air deflector and allow 2 minutes for the air coming out to feel cold. Use the remote control to adjust fan speed. Keep the temperature setting at 17 °C unless the air flow feels too cold.

  5. Keep a door or window open so fresh air circulates unless it is extremely hot or windy outside.

  6. Avoid using a fan nearby as it can disrupt Coolzy’s gentle air flow.

  7. The focus enhancer extends the range of cooling and, after fitting the separate transparent deflector flap, enables a higher angle of air flow.
    • For a small room, place the unit near an open window or doorway.
    Setup

Position Coolzy close enough for comfort. The ideal range of distance is 1.5 – 3 metres. Arrange the angle of the cold air deflector so cool air flows around face and shoulders. Use the optional Igloo tent for a more intense cooling effect and insect protection. We recommend using the Igloo tent for sleeping if indoor temperature is consistently over 27-29 °C.

ideal range of distance

For sleeping, arrange your unit about  15cm from the end of the bed. Adjust the cold air deflector and focus enhancer to the desired angle so the cool air flows over your face and upper body. It also works with larger beds for two people.

Setup

DEHUMIDIFICATION

Coolzy will condense water from the room air in humid weather conditions. Normally this water evaporates into the air emerging from the warm air outlet, improving the cooling power.

To collect the condensed water instead, open the cable drawer and remove the rubber bung just above it. This will allow some of the condensated water to collect in the drawer. When the cable drawer is full, the white water drop indicator comes on and Coolzy will pause. Carefully remove the cable drawer and empty the water. The cable drawer can store about two litres of condensed water.

Remember to replace the rubber bung for normal, high efficiency cooling.

Dehumidification

FOCUS ENHANCER

Coolzy has a focus enhancer nozzle that adjusts the cool air throw.

Focus Enhancer

Push the blue nozzle down for a more focused air flow that cools at a greater distance. Lift the nozzle for a gentler flow.

Make sure the nozzle is pushed down before closing the cool air deflector.

For a higher angle of air flow, attach the transparent flap to the end of the cool air deflector. Make sure the straight edge is facing you and the two notches slide under the cool air deflector.

To remove, simply pull the flap off.

Tips

  • Adjust the angle of the cool air deflector to ensure that cool air flows past face and neck
  • Turn off fans when using Coolzy. Drafts from nearby windows and fans may disrupt the focus enhancer air jet.
  • Pull the focus enhancer nozzle upright for use with the bed tent. If the focus enhancer nozzle is in the down position, the cool air at the bottom of the tent will mix with the warm air at the top.
  • In humid weather, it is normal for moisture to condense on parts of the focus enhancer.

CHECKING AND CLEANING AIR FILTERS

We recommend inspecting at least the return air inlet filter once every two weeks. Once there is a noticeable amount of dust, clean all three filters by rinsing them under running water.
Remove the focus enhancer to access the foam filter beneath it. Replace the focus enhancer after cleaning the foam filter.

  • Return Air Inlet Filter
    Return Air Inlet Filter

  • Removing Enhancer
    Removing Enhancer

  • Room Air Inlet Filter
    Room Air Inlet Filter

In dusty locations, consider arranging for an air conditioning technician to clean the inside before the summer season.

INDICATOR LIGHTS

Power (green light)

This shows that the electrical power is on. When the green light flashes, Coolzy is waiting 1 – 2 minutes for the compressor to start cooling.

Water drop (white light)

In normal conditions, all the water condensed inside the cooler will evaporate into the air emerging from the warm air outlet. This evaporation increases the cooling performance in humid conditions.

If you remove the rubber bung, following the dehumidification instructions below, condensed water flows into the cable drawer instead. The water drop light comes on when the cable drawer is full of water.

The water drop light also comes on if the cable drawer is not fully inserted and flush with the back panel.

When it is extremely humid, greater than 95% lasting for several hours, water can overflow from the cooler into the cable drawer.

If the water drop light is on, carefully remove the cable drawer and empty any water. If there is no water, then carefully push the drawer into Coolzy until it is flush with the back panel.

Snowflake (blue light)

The cooler temperature so low that there is a risk that ice may form, damaging the tubes in Coolzy. Some combinations of low temperature, humidity and atmospheric pressure can lead to frosting. Allow the fan to operate for a few minutes to warm up Coolzy.

Also, check the air inlet filters for excessive dust build-up. Ensure that there is nothing blocking the either of the air inlets such as a curtain, cushion or bedding.

Thermometer (red light)

The compressor has overheated. Coolzy can be used in ambient temperatures up to 40 °C. Above that temperature, the compressor may overheat. Wait for 10 – 20 minutes and try again. Avoid using Coolzy in direct sunlight.
Check the air inlet filters for excessive dust build-up. Ensure that there is nothing blocking the either of the air inlets such as a curtain, cushion or bedding.

TOUBLESHOOTING

Symptom 1 – Green light is not on when trying to turn on Coolzy

Make sure the warm air deflector is fully open. Check to see if the power supply is properly connected and on. The unit will make a “beep” sound when plugged in to power. If the power cord seems properly connected, try a different power supply. Check that the cable drawer is fully inserted and flush with the back of Coolzy.

Symptom 2 – Green light is on with no cooling

The green light flashes, the fan runs and the compressor waits to start cooling for about 90 seconds. This delay protects the compressor from damage.
If the green light is on and the fan is running, and there is no apparent cooling after 2 minutes, check that Coolzy is in cooling mode. Press the ‘FUNC’ button on the remote until the snowflake icon appears to activate cooling mode. Reduce the temperature setting because the thermostat may be preventing the compressor from starting.

Symptom 3 – Green light is flashing continuously

If the green light flashes repeatedly but the fan is not running, this may be due to surge protection mode or an unstable power supply. Turn off the unit using the remote and close the rear flap. Unplug the unit and wait for 5 minutes. When reconnecting to the power supply, a “beep” sound should be heard.

Symptom 4 – Room seems to warm up

As you become accustomed to the cool microclimate that Coolzy provides for you, the other parts of the room may seem to be warmer. There may be a slight increase in air temperature in the space above the warm air deflector, but this is normally not enough to heat up the lower part of the room.

Keep a door or window open. This is a healthy option. Position Coolzy’s warm air outlet to face the open window or door so warm air can flow out more easily. Unlike normal room air conditioners, Coolzy works just best with open doors or windows and fresh air circulating.

A slight temperature increase can occur in a small room, especially if the windows are closed. The setup instructions show how to minimize this effect.

Symptom 5 – Gradual loss of cooling

Dust accumulating on the air filters will reduce the cooling. Clean all three air filters following the instructions in this guide.

SUPPORT

www.coolzy.com provides FAQs and helpful information, updated frequently, along with your local retailer and service agent information and your local customer support phone number.

Ask any general, support, warranty or technical questions by emailing us at contact@coolzy.com.

SPECIFICATIONS

COOLZY|
---|---
Model number| PC9RL
Power source| 220 – 240 V AC, 50 Hz
Minimum operating voltage| 185 V
Power input| 340 W(33°C, 80%RH)
Compressor type| Rotary
Cooling capacity *| 850 W – 1150 W (3000 – 4000 BTU/hr)
Cool air flow rate| 80 – 115 m3/hr variable
Cool side temperature reduction| 8 – 16 °C
Refrigerant| R290, 109 g
Power cord, storage drawer †| 4 m, 2.5 litres
Operating environment (indoors)| 20 °C – 40 °C
Width| 273 mm (packed 310)
Depth| 385 mm (packed 410)
Height| 550 mm (packed 610)
Weight| 15.4 kg (packed 16 kg)
Noise ‡| 46 – 54 dBA
Wheels| 4 caster wheels
Remote control| infrared – temperature, fan speed adjust
Plumbing and pipes needed| None
Consumables needed| None
Filter cleaning| Check every 2 weeks

  • Cooling power output ranges up to 1150 Watts with condensed water automatically evaporated, depending on local temperature and humidity. Electrical power consumption varies with temperature and humidity.
    † Drawer can optionally be used to collect condensed water to top up batteries.
    ‡ Apparent noise level in bedroom, depends on fan speed.

WARRANTY

Coolzy and accompanying accessories are warranted by Close Comfort Pty Ltd (ABN 81 128 172 083) (”Close Comfort Australia”) against defects in design, materials and workmanship. The warranty period is 2 years from the date of original purchase, provided the purchaser registers details at https://www.coolzy.com/au/support/warranty/. Without purchase registration, the warranty period is one year. This Warranty is only valid for the Australian and New Zealand market.

Equipment defects covered by this warranty will be repaired or replaced at the discretion of Close Comfort Australia without cost to the owner for parts of direct repair labour. The purchaser will need to return the product(s) to an authorised Coolzy Dealer, agent or Close Comfort Australia for warranty repairs. In-home service is not provided. The owner is responsible for all transport costs and in-transit insurance associated with returning the unit to the authorised repair centre. In some cases, the purchaser will be able to perform the necessary repair or replacement.

Any parts or equipment replaced under this warranty will be warranted in accordance with the provisions of this warranty for the remainder of the original warranty period. Rights defined in this warranty are in addition to rights afforded by the Australian Consumer Law.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Warranty Exclusions
  1. . Damage or problems or unsatisfactory performance caused to the unit by faulty or incorrect external wiring, incorrect power supply, voltage fluctuations, over voltage transients or electromagnetic interference not originating within the unit.
  2. Damage or problems caused by the use of an accessory, component or equipment not supplied by Close Comfort Australia.
  3. Damage or problems caused by storm, fire, flood, vandalism, negligence, accidental damage, Acts of God, earthquake, war, vermin, foreign matter entering the unit (e.g. dirt and moisture) or any other outside agency.
  4. Freight charges (including insurance) incurred by the owner in returning the unit to Close Comfort Australia or an authorised repair centre, dealer or agent.
  5. In-home or on-site service and any associated costs.
  6. Any consumable items (e.g. batteries) supplied with the unit unless the item is shown to be defective at the time of purchase.
  7. Damage or problems or unsatisfactory performance resulting from operation in an environment where the environmental comfort of humans is not the primary function of the unit.
  8. Damage caused by operation in a corrosive atmosphere or excessive humidity.
  9. Damage of problems or unsatisfactory performance resulting from operations at conditions outside the operating conditions specified in the Close Comfort Australia technical or sales literature applicable to the unit.
  10. Damage or problems or unsatisfactory performance resulting from misapplication of the unit.
  11. Damage or problems or unsatisfactory performance resulting from leaking or exhausted batteries.
  12. Damage or problems caused by repair work performed by a person who has not been authorised by Close Comfort Australia to perform repairs.
Owner’s Responsibilities

a. Operation and maintenance of the unit in accordance with the operating instructions as provided with the unit.
b. Regular cleaning of the air filters (every 2 weeks) and replacement if damaged.
c. Replacement of exhausted batteries, in the remote control.
d. Cleaning of heat exchangers by a qualified air conditioner technician in the event of excessive dust accumulation on the fins and tubes.

Steps to Claim Warranty
  1. Stop using the unit entirely and unplug it from any power source
  2. Contact the retailer from which the product(s) were purchased.
  3. If the product(s) were purchased directly from Close Comfort Australia, report the fault and provide a detailed description with photographs, sound recording or video if possible. Email these details to contact@coolzy.com, or use the contact form at https://www.coolzy.com/.
  4. Once acknowledged, follow instructions by Close Comfort Australia on preparing and sending unit for warranty assessment.
  5. Provide evidence of the original purchase, such as a retailer’s sales receipt, or evidence of payment of an original tax invoice.

Disposal

Symbols Electrical appliances left in dumps or landfill waste sites can cause hazardous materials to be released into local water reservoirs and soil, potentially contaminating food and water supplies.
Therefore, please do not dispose of electrical appliances as unsorted municipal waste. Use designated recycling collection facilities. Contact your local government for information on appropriate disposal sites.

COOLZY  Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals