COOLZY-GO PC9B Portable Air Conditioner User Guide

June 2, 2024
COOLZY-GO

COOLZY-LOGO

COOLZY-GO PC9B Portable Air Conditioner

Coolzy products are distributed in the USA by Close Comfort International Pte Ltd, Singapore, UEN 201527973E.

USER GUIDE AND WARRANTY

  • Read the safety precautions first!
  • Avoid using this product in a wet environment.
  • Ensure that anyone using this product is aware of normal safety precautions for household electric appliances.

PARTS

COOLZY-GO-PC9B-Portable-Air-Conditioner-FIG-1

LED INDICATOR PANEL

COOLZY-GO-PC9B-Portable-Air-Conditioner-FIG-2

GETTING STARTED

IMPORTANT
Always keep Coolzy upright. It may have been stored or transported on it’s side or laid flat by mistake, so please stand it upright for at least 12 hours before plugging it into power and turning it on. Failing to do so may damage the unit

Drape a curtain as shown to exclude light when sleeping. Make sure that the room air intake is at least 6 in (15 cm) from the wall!

  1. After removing Coolzy from the box, place it in an upright position.
  2. Remove the cable from the drawer at the back of the unit and insert the plug into a wall outlet. Make sure you push the drawer fully back in so it is flush with the back panel.
  3. Open the warm air deflector fully. This will turn on the unit and the compressor will start.
  4. Open the cold air deflector and allow 2 min-utes for the air coming out to feel cold.
  5. Keep a door or window open so fresh air circu-lates unless it is extremely hot or windy outside.
  6. Avoid using a fan nearby as it can disrupt Coolzy’s gentle air flow.
  7. An adjustable nozzle (Focus Enhancer) is avail-able for purchase as an accessory. It extends the range of cooling and, after fitting the transparent flap that comes with it, enables a higher angle of air flow.

For a small room, place the unit near an open window or doorway.

Position Coolzy close enough for comfort. The ideal range of distance is 5 – 10 feet (1.5 – 3 metres). Arrange the angle of the cold air deflector so cool air flows around face and shoulders. For sleeping, arrange your unit about 6 inches (15cm) from the end of the bed. Adjust the cold air deflector to the desired angle so the cool air flows over your face and upper body. It also works with larger beds for two people.

Use the optional Igloo tent for a more intense cooling effect and insect protection. We recommend using the Igloo tent for sleeping if indoor temperature is over 80 °F (27 °C).

DEHUMIDIFICATION

Coolzy condenses water from the room air in humid weather conditions. Normally this water evaporates into the air emerging from the warm air outlet, improving the cooling power. To collect the condensed water instead, open the cable drawer and remove the stopper just above it. This will allow some of the condensed water to collect in the drawer. When the cable drawer is full, the white water drop indicator comes on and Coolzy will pause. Carefully remove the cable drawer and empty the water. The cable drawer can store about two litres of condensed water. Remember to replace the stopper for normal, high efficiency cooling

COOLZY-GO-PC9B-Portable-Air-Conditioner-FIG-7

USER MAINTENANCE

We recommend inspecting at least the return air inlet fi lter once every two weeks. Once there is a noticeable amount of dust, clean all three fi lters by rinsing them under running water.

COOLZY-GO-PC9B-Portable-Air-Conditioner-FIG-8

Remove the cool air outlet grille to access the foam filter beneath it. Replace the grille after cleaning the foam filter. In dusty locations, consider arranging for an air conditioning technician to clean the inside before the summer season. The refrigerant circuit is permanently welded: there is no need to recharge the gas.

INDICATOR LIGHTS

Power (green light)
This shows that the electrical power is on. When the green light fl ashes, Coolzy is waiting 1 – 2 minutes for the compressor to start cooling.

Water drop (white light)
In normal conditions, all the water condensed inside the cooler will evaporate into the air emerging from the warm air outlet. This evaporation increases the cooling performance in humid conditions. If you remove the stopper, following the dehumidification instructions, condensed water fl ows into the cable drawer instead. The water drop light comes on when the cable drawer is full of water. The water drop light also comes on if the cable drawer is not fully inserted and fl ush with the back panel.
When it is extremely humid, greater than 95% lasting for several hours, water can overfl ow from the cooler into the cable drawer.
If the water drop light is on, carefully remove the cable drawer and empty any water. If there is no water, then carefully push the drawer into Coolzy until it is fl ush with the back panel.

Snowflake (blue light)
The cooler temperature so low that there is a risk that ice may form, damaging the tubes in Coolzy. Some combinations of low temperature, humidity and atmospheric pressure can lead to frosting. Allow the fan to operate for a few minutes to warm up Coolzy. Also, check the air inlet filters for excessive dust build-up. Ensure that there is nothing blocking the either of the air inlets such as a curtain, cushion or bedding.

Thermometer (red light)
The compressor has overheated. Coolzy can be used in ambient temperatures up to 104 °F (40 °C). Above that temperature, the compressor may overheat. Wait for 10 – 20 minutes and try again. Avoid using Coolzy in direct sunlight. Check the air inlet filters for excessive dust build-up. Ensure that there is nothing blocking the either of the air inlets such as a curtain, cushion or bedding.

TROUBLESHOOTING

Symptom 1 – Green light is not on when trying to turn on Coolzy
Make sure the warm air defl ector is fully open. Check to see if the power supply is properly connected and on. If the power cord seems properly connected, try a different power supply. Check that the cable drawer is fully inserted and flush with the back of Coolzy.

Symptom 2 – Green light is on with no cooling
The green light fl ashes, the fan runs and the compressor waits to start cooling for about 90 seconds. This delay protects the compressor from damage.
If the green light is on and the fan is running, and there is no apparent cooling after 2 minutes, check the room air temperature. The compressor will only run at an air temperature greater than 63 °F (17 °C).

Symptom 3 – Water sloshing noise
In extremely high humidity, the production of condensed water may exceed the capacity to evaporate water at the condenser heat exchanger. As more water accumulates than in normal conditions, there may be a perceptible sound of water cascading off the condenser at the back of the machine. This is normal behaviour. If the sound is annoying, consider removing the stopper temporarily. The water will drain into the cable drawer. However the machine will stop cooling when the cable drawer is full of water.

Symptom 4 – Room seems to warm up
As you become accustomed to the cool microclimate that Coolzy provides for you, the other parts of the room may seem to be warmer. There may be a slight increase in air temperature in the space above the warm air defl ector, but this is normally not enough to heat up the lower part of the room.
Keep a door or window open. This is a healthy option. Position Coolzy’s warm air outlet to face the open window or door so warm air can flow out more easily. Unlike normal room air conditioners, Coolzy works just best with open doors or windows and fresh air circulating. A slight temperature increase can occur in a small room, especially if the windows are closed. The setup instructions show how to minimize this effect. Visit www.coolzy.com for more suggestions to improve ventilation.

Symptom 5 – Gradual loss of cooling
Dust accumulating on the air filters will reduce the cooling. Clean all three air filters following the instructions in this guide.

SUPPORT

www.coolzy.com provides FAQs and helpful information, updated frequently, along with your local retailer and service agent information and your local customer support phone number. Ask any general, support, warranty or technical questions by emailing us at contact@coolzy.com.

SPECIFICATIONS

COOLZY

  • Model number PC9B
  • Power source 120 V AC, 60 Hz
  • Minimum operating voltage 90 V
  • Rated power input 425 W (40 °C, 104 °F, 35% RH)
  • Typical power input 320 W (33 °C, 91 °F, 80% RH)
  • Compressor type Reciprocating
  • Cooling capacity * 3300 – 4500 BTU/hr (800 W – 1100 W)
  • Cool air fl ow rate 57 ft3/min, 105 m3/hr
  • Cool side temperature reduction 14 – 24 °F (8 – 16 °C)
  • Refrigerant R134a, 0.47 lb, 215 g
  • Power cord, storage drawer † 12 feet (4 m), 5 pints (2.5 litres)
  • Operating environment (indoors) 68 °F – 104 °F (20 °C – 40 °C)
  • Width 11 in, 273 mm (packed 12 in)
  • Depth 15 in, 385 mm (packed 16 in)
  • Height 22 in, 550 mm (packed 24 in)
  • Weight 37 lb, 17 kg (packed 43 lb)
  • Noise ‡ 52 dBA
  • Wheels 4 swivel wheels
  • Plumbing and pipes needed None
  • Consumables needed None
  • Filter cleaning Check every 2 weeks

Cooling power ranges up to 1100 Watt with automatic evaporation of condensedwater, depending on local temperature and humidity. Electricity consumption variesdepending on temperature and humidity. Drawer can optionally be used to collect condensed water. Apparent noise level in bedroom, depends on fan speed and furnishings.

Fuse parameters of the machine

  • Type : 5H or 524
  • Voltage : 250V
  • Current : 3.15 A

WARRANTY

Coolzy and accompanying accessories are warranted against defects in design, materials and workmanship. The warranty period is 2 years from the date of original purchase, provided the purchaser registers their details at www.coolzy.com/us/support/warranty/. Without purchase registration, the warranty period is one year. This warranty is valid for the USA and Canada. Defects in equipment covered by this warranty will be repaired or replaced at Close Comfort’s option at no charge to the purchaser for parts or direct repair labour. The purchaser must return the product(s) to an authorized Coolzy dealer or agent for warranty repairs. Home service is not provided. The purchaser is responsible for all transportation costs and in-transit insurance associated with returning the device to the authorized repair centre. In some cases, the purchaser will be able to make the necessary repair or replacement.

Any part or equipment replaced under this warranty will be warranted in accordance with the following provisions with the terms of this warranty for the remainder of the original warranty period, or 60 days from return, whichever is greater. THE PROVISIONS OF THIS LIMITED WARRANTY ARE IN LIEU OF ANY OTHER WRITTEN WARRANTY, EXPRESS OR IMPLIED, WRITTEN OR ORAL (INCLUDING WARRANTIES RELATING TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE). IN NO EVENT SHALL THE SELLER OR CLOSE COMFORT BE LIABLE FOR ANY SPECIAL, INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES. Nothing in the limited warranty limits or restricts any rights granted by national consumer legislation.

Warranty Exclusions

  1. Damage, trouble, or unsatisfactory performance of the device caused by faulty or improper external wiring, improper power supply, voltage fl uctuations, power surges, or electromagnetic interference not originating from the device.
  2. Damage or problems caused by the use of an accessory, component or equipment not supplied by Close Comfort.
  3. Damage or trouble caused by storm, fire, fl ood, vandalism, negligence, accident, force majeure, earthquake, war, vermin, foreign matter entering the device (e.g. dirt and moisture) or any other outside organism.
  4. Freight charges (including insurance) incurred by the owner in returning the appliance to Close Comfort or an authorized repair center, dealer or agent.
  5. In-home or on-site service and all associated costs.
  6. Any consumable item supplied with the device, unless the item is found to be defective at the time of purchase.
  7. Damage or problems or unsatisfactory performance resulting from operation in an environment where the environmental comfort of people is not the primary function of the unit.
  8. Damage caused by operation in a corrosive atmosphere or excessive humidity.
  9. Damage from problems or unsatisfactory performance resulting from operations under conditions other than those specified in the Close Comfort technical or commercial documentation applicable to the device.
  10. Damage, trouble or unsatisfactory performance resulting from misapplication of the unit.
  11. Damage or problems caused by repair work carried out by someone who has not been authorized by Close Comfort to carry out repairs

Owner responsibilities

  1. Use and care of the device in accordance with the instructions for use provided with the device.
  2. Regular cleaning of air filters (every two weeks) and replacement if damaged.
  3. Cleaning of the heat exchangers by a qualified air conditioning technician in the event of excessive accumulation of dust on the fins and the tubes.

Warranty claim steps

  1. Stop using the device and unplug it from any power source.
  2. Contact the retailer where the product(s) were purchased.
  3. If the product(s) were purchased directly from Close Comfort, report the defect and provide a detailed description with photos, sound recording or video if possible. Email these details to contact@coolzy.com, or use the contact form at www.coolzy.com/.
  4. Once acknowledgment is received, follow Close Comfort’s instructions on preparing to return and sending unit for warranty evaluation.
  5. Provide proof of original purchase, such as a retailer’s sales receipt, or proof of payment of an original tax invoice

DISPOSAL
This marking indicates that this product should not be disposed with other household wastes. To prevent possible hazards to the environment or human health from uncontrolled waste disposal, please recycle it to prove the sustainable reuse of material resources. Please ask ‘return and collection’ systems or contact the retailer where the product was purchased to return your used device, they can recycle products safely

SAFETY PRECAUTIONS

CAUTION!

  1. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  2. This appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.)
  3. Do not pierce or burn this appliance.
  4. Be aware that refrigerants may not contain an odour.

Refrigerant gas
The refrigerant gas in this appliance is R134a. The quantity used in this Coolzy is about 215 grams. You may not be able to smell leaking gas. R134a is a non-toxic gas.

Before operating this appliance
This appliance must stand upright at all times. If you are unsure whether the appliance has been stored or transported upright, stand the appliance upright for at least 12 hours before turning it on to allow liquid refrigerant inside the appliance tubing to drain to the bottom. Make sure that the electric cable to the appliance is undamaged and in good condition.

Operating this appliance
This appliance designed for localised cooling. It can also provide dehumidification above a temperature of 20 ˚C by removing the rubber bung temporarily. Do not use this appliance for purposes other than its intended uses. Operate this appliance in a ventilated space. We recommend keeping at least one window or door at least partly open at all times. Make sure that air can pass easily to the inlets and away from the outlets of this appliance. Keep the appliance sufficiently far from curtains or furniture to enable free air movement. Operate the appliance on a horizontal surface to avoid water leakage. If you use this appliance on a table or platform above the fl oor, make sure it cannot roll off the platform by accident.

Do not use this appliance in a corrosive atmosphere. Avoid using this appliance in a wet area such as a washroom. Avoid using this appliance in an ambient temperature above 104 °F (40 ˚C). Wait at least 2 minutes after switching this appliance off before turning it on again to avoid damage to the compressor. After switching on the unit, the compressor will start after about 1.5 minutes as a further precaution to protect the compressor. The peak current needed by this appliance can be as high as 14 amps at the instant of starting the compressor. Using an extension cord or unreliable electrical connectors can be dangerous. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be performed by children without supervision.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

Storing this appliance
Make sure the appliance is stored safely to protect it from damage that could cause refrigerant leakage. Local regulations may restrict the maximum number of appliances that can be stored in one location.

Maintaining this appliance
Keep the appliance clean using a moist cloth with the least possible cleaning agent if needed. Make sure you inspect the filters regularly and remove any accumulation of dust by gently rubbing and rinsing the filters in clean water. Do not use any sharp tools to remove dust or dirt from this appliance.

Servicing this appliance
An authorised and appropriately trained refrigeration or air conditioning technician is required for repairs to the electric cable or servicing for any component that requires removal of the outside casing. Close Comfort will provide advice needed to enable technicians to service Close Comfort products.
All servicing must be performed in a well ventilated space.

Transport
Before packing the appliance, remove the stopper and tilt the device to drain any remaining water. Replace the stopper once the water has been drained.
This appliance must be transported upright, preferably protected by the original packaging. Please comply with local transport regulations on handling appliances with a small quantity of refrigerant

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>