HTRS-RF Wireless Digital Thermostat
Instruction Manual
Introduction
HTRS-RF(30) is a wireless digital room thermostat compatible with devices that
are part of the iT600 series, such as: KL08RF wiring centre, TRV10RFM
thermostatic radiator valve and RX10RF boiler receiver. If you want the
thermostat to control the devices via Internet (Online Mode), please use the
UG600 universal gateway and connect it to the SALUS Smart Home app. You can
also use the thermostat to control the devices locally without Internet
connection (Offline Mode) but in this case the communication between devices
must be done using the CO10RF coordinator.
Product Compliance
This product complies with EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and
RoHS 2011/65/EU. Full text of the EU Declaration of Conformity on
www.saluslegal.com 2405-2480MHz; <14dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device
completely dry. Disconnect your device before cleaning it with a dry cloth.
Wiring diagram
Power supply: 2 x AA alkaline batteries
S1 & S2 terminals:– external temperature sensor (air or floor)
– external switch (occupancy sensor)
Mounting: surface mounting (after removing the back case)
LCD icons
- Comfort temperature
- Standard temperature
- Reduced temperature
- Auto mode
- Frost protection mode
- Heating Mode ON
- RF signal
- Internet connection
- Cooling Mode ON
- Manual Mode/Temporary Override
Button functions
| |
---|---|---
Mode selection.
Long press to return to main screen without saving.
Short press to return to previous screen.| Decrease or increase
Setpoint Temperature.| OK key. Short press to confirm selection.
Long press to save and return to main screen.
Button combinations
|
---|---
Press and hold the buttons simultaneously to lock or unlock the keypad.| Press
and hold the buttons simultaneously to enter installer mode.
Zigbee network coordinators
I. Online: connected to the Internet using the UG600 universal gateway.
II. Offline: with the possibility of connecting to the Internet using the
UG600 universal gateway.
III. Offline: without any possibility of connecting to the Internet using the
CO10RF coordinator.
Select the device that is going to be controlled by the thermostat and the type of Zigbee network coordinator you want to use. Install the devices according to the instructions attached to each product.
Power up
After inserting the batteries, the thermostat will display the software version and it will power up.
After the first power up, you can choose to pair the thermostat either with
underfloor heating (UFH) or with radiators (rAd):
: KL08RF wiring centre
: TRV10RFM thermostatic radiator valve
Extended configuration
Extended configuration should be used only if you want to pair the thermostat with the boiler receiver. To do so, press the buttons shown below simultaneously until all visible icons flash once.
3. Choose the device type according to the screens below:
: Undefloor heating
: Radiator heating
: RX10RF in RX1 mode
: RX10RF in RX2 mode
OFFLINE PAIRING PROCEDURE
The offline pairing method should be used by non-internet users only.
WARNING! Do not use CO10RF coordinator with UG600 simultaneously.
Pairing with the Wiring Centre
Select on the LCD.
Select the wiring centre number using or (max 9). Confirm your
choice by pressing .
.
Select the group number (offline only) using or . Confirm your choice by pressing .
Select the zone number using or .Confirm your choice by pressing .
Pairing with the TRV
WARNING! You can connect up to 6 TRVs to one thermostat.
Press and hold the button for 10 seconds. The LED will start flashing red.
Select on the LCD
Press to confirm the pairing with the TRV.
Press . The LED on the TRV will flash green one time and then it will turn off.
The LCD will display the number of paired devices.Press to finish.
Pairing with the boiler receiver
WARNING! In a ZigBee network, you can use only one RX10RF configured as RX1 and only one RX10RF configured as RX2.
In order to pair directly the thermostat with the boiler receiver, please follow the Extended configuration procedure.
ONLINE PAIRING PROCEDURE
Please use the online pairing method when you are using UG600 to configure your system. Follow the on-screen instructions to complete the setup.
Go to the App
Identify paired devices
Go to Installer Mode, select parameter 00 and press .
Press to exit installer mode.
Change temperature setpoint
If thermostat works in AUTO mode, then the overwritten temperature (temporary override) will be maintained until next program. In manual mode and frost protection mode temperature change is permanent.
Factory Reset
Head Office:
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP , UK.
T: +44 (0) 1226 323961
sales@salus-tech.com
techsupport@salus-tech.com
UK: tech@salus-tech.com
tel: +44 (0) 1226 323961
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc
reservthe right to change specification, design and materials of products
listbrochure without prior notice.
For PDF Installation guide please go to www.salus-manuals.com
Issue date: Apr 2019
Version: V019
531MSLG3CF132
Documents / Resources
|
SALUS HTRS-RF Wireless Digital
Thermostat
[pdf] Instruction Manual
HTRS-RF Wireless Digital Thermostat, HTRS-RF, Wireless Digital Thermostat,
Digital Thermostat, Thermostat
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>