Aeotec illumino Wall Switch ZWA038-A Manual
- June 8, 2024
- Aeotec
Table of Contents
- Aeotec
- illumino Wall Switch
- SKU: ZWA038-A
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 119: External Switch Scene
- Parameter 120: External Switch Type
- Parameter 121: Output Control
- Parameter 122: Button Function
- Parameter 123: Report Behavior
- Parameter 20: Power Restore
- Parameter 40: Auto Turn Off Timer
- Parameter 41: Auto Turn On Timer
- Parameter 80: Instant Status Report
- Parameter 82: Association Control Settings
- Parameter 83: Led Indicator Settings
- Parameter 84: Led Indicator Color For Output
- Parameter 85: Led Indicator Color For Scene
- Parameter 86: Led Brightness
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aeotec
illumino Wall Switch
SKU: ZWA038-A
Quickstart
This is a
secure
Binary Switch
for
.
To run this device please connect it to your mains power supply.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Aeotec illumino Wall Switch is a Z-Wave Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches.In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.It can connect to external manual switches to control the load ON/OFF independently. The illumino Wall Switch is also a security Z-Wave Plus device and supports Over The Air (OTA) feature for the products firmware upgrade.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Lifeline group. |
---|---|---|
2 | 5 | Top button set ON/OFF |
3 | 5 | Buttom button set ON/OFF |
4 | 5 | External switch set ON/OFF |
5 | 5 | Top and Bottom button set ON/OFF |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 119: External Switch Scene
Enable or disable the scenefunction of external(3-way)switch.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Disable |
---|---|
1 | Enable |
Parameter 120: External Switch Type
Select the external(3-way)switch’s type.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | toggle on or off only |
---|---|
1 | NO momentary switch |
2 | NC momentary switch |
Parameter 121: Output Control
Enable or disable output.
Size: 1 Byte, Default Value: 3
SettingDescription
0 | Disable |
---|---|
1 | enable local control |
2 | enable central scene |
3 | enable local and central scene |
Parameter 122: Button Function
Select the paddle buttonfunctions.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | up/ON, down/OFF |
---|---|
1 | down/ON, up/OFF |
2 | toggle (up or down are the same) |
Parameter 123: Report Behavior
Select behavior for report andindicator when output is disable.
Size: 1 Byte, Default Value: 0
SettingDescription
0| 0-report on/off status and change LED indicator when parameter 121 is set
to 0 or 2
---|---
1| 1-Don’t report on/off status is pressed and parameter 121 is set to 0 or 2
Parameter 20: Power Restore
Status after power failure.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | return to OFF |
---|---|
1 | return to ON |
2 | returns to last known state when repowered |
Parameter 40: Auto Turn Off Timer
Timer that auto turn off onceturned on.
Size: 4 Byte, Default Value: 0
SettingDescription
0 | Disable |
---|---|
1 – 65535 | Auto turn off after 1s once turned on 65535 – Auto turn off after |
65535s once turned on
Parameter 41: Auto Turn On Timer
Timer that auto turn on onceturned off.
Size: 4 Byte, Default Value: 0
SettingDescription
0 | Disable |
---|---|
1 – 65535 | auto turn on after 1-65535s once turned off. |
Parameter 80: Instant Status Report
The command for status report.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | Nothing |
---|---|
1 | Basic Report |
2 | Binary Switch Report |
Parameter 82: Association Control Settings
Setting command for associationgroup.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | Basic Set |
---|---|
2 | Binary Switch Set |
Parameter 83: Led Indicator Settings
Select the indicator function foroutput.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | Disable |
---|---|
1 | Momentary blink |
2 | LED follows status of output |
Parameter 84: Led Indicator Color For Output
Select the indicator color foroutput.
Size: 1 Byte, Default Value: 9
SettingDescription
0 | Disable |
---|---|
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Puple |
7 | Orange |
8 | Yellow |
9 | White |
Parameter 85: Led Indicator Color For Scene
Select the indicator color forscene.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | Disable |
---|---|
1 | Red |
2 | Blue |
3 | Green |
4 | Pink |
5 | Cyan |
6 | Purple |
7 | Orange |
8 | Yellow |
9 | White |
Parameter 86: Led Brightness
Setting the brightness ofindicator.
Size: 1 Byte, Default Value: 60
SettingDescription
0 | Disable |
---|---|
1 – 100 | 1%-100% level |
Technical Data
Hardware Platform | ZGM130 |
---|---|
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.02 |
Z-Wave Version | 7.13.9 |
Certification ID | ZC12-21080286 |
Z-Wave Product Id | 0x0371.0x0103.0x0026 |
Color | White |
Neutral Wire Required | ok |
Firmware Updatable | Updatable by Consumer by RF |
Z-Wave Scene Type | Scene & Central Scene |
Electric Load Type | Dimmable ELV (Magnetic)Dimmable FluorescentDimmable |
LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive
(e.g. Motor)LEDMLV (Magnetic)
Switch Type| Toggle
Security V2| S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency| XXfrequency
Maximum transmission power| XXantenna
Supported Command Classes
- Association Grp Info V3
- Association V3
- Basic V2
- Central Scene V3
- Configuration V4
- Device Reset Locally
- Firmware Update Md V5
- Indicator V3
- Manufacturer Specific V2
- Multi Channel Association V4
- Powerlevel
- Scene Activation
- Scene Actuator Conf
- Security 2
- Supervision
- Switch Binary V2
- Transport Service V2
- Version V3
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>