Aeotec Door / Window Sensor 7 Pro ZWA012-A Manual

June 8, 2024
Aeotec

Aeotec

Door / Window Sensor 7 Pro

SKU: ZWA012-A

Quickstart

This is a
secure
Alarm Sensor
for
.

Please make sure the internal battery is fully charged.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Aeotec Door/ Window Sensor 7 Pro is built on the 700 series Z-Wave technology. Its a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. It also supports connecting external binary sensors with a dry contact through the dry binary contact of the Door/ Window sensor. Using the latest technology it supports the highest Z-Wave security level of S2 and SmartStart.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 5 Lifeline to Gateway
2 5 Control devices when a magnet or external dry contacts trips
3 5 Sends out alarm message when a magnet or external dry sensor trips
4 5 Sends alarm messages when tamper is tripped
5 5 Control devices when tilting sensor trips

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Sensor Operation Mode

This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Internal Magnet Sensor Used and scene activation enabled
1 – 0 External Terminal Inputs Used and scene activation disabled

Parameter 10: Time Delay of u0022Onu0022 command frame

On command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 32400 seconds

Parameter 11: Time Delay of u0022Offu0022 command frame

Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 32400 seconds

Parameter 12: Delay of Tamper Alarm Cancellation

Time a tamper alarm is delayed.
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 32400 seconds

Parameter 13: Reporting Tamper Alarm Cancellation

This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1

SettingDescription

0 Do not send Report
1 – 0 Send Report

Parameter 14: Central Scene Event Functionality

This parameter enables/disablesthe central scene function.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Disabled
1 – 0 Enabled

Parameter 15: Tilt Sensor Functionality

This parameter enables/disablesthe tilt function.
Size: 1 Byte, Default Value: 1

SettingDescription

0 Disabled
1 – 0 Enabled

Parameter 16: Tilt Sensor State

This parameter allows to set in what state is door/window when the tilt is in an OFF state.
Size: 1 Byte, Default Value: 0

SettingDescription

0 OFF when sensor is vertical
1 – 0 ON when sensor is vertical

Parameter 17: 5th Association Group triggers

Parameter defines events which result in sending On/Off commands to devices added to the 2nd Association Group. These commands are sent alternately to switch the devices On and Off. Commands represent the values of BASIC SET command frames.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Switch after Open and Close
1 Switch after Open
2 Switch after Close

Parameter 18: Commands sent to 5th Association Group

Command frames sent to devices added to the 5th association group.
Size: 1 Byte, Default Value: 2

SettingDescription

0 On
1 Off
2 On and Off

Parameter 19: Value of ON command frame sent to 5th Associatio

The value of 0 turns OFF the device, 255 turns it On. In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level.0-99 or 255
Size: 1 Byte, Default Value: 255

SettingDescription

0 – 99 Value
255 Value

Parameter 2: Dry Contact Operation Mode

Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact terminals.0 – NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN.1 – NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN.2 – NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal.3 – NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal.
Size: 1 Byte, Default Value: 0

SettingDescription

0| NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN.
---|---
1| NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN.
2| NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal.
3| NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal.

Parameter 21: Tilt sensitivity

You can use this parameter to adjust the tilt sensitivity if the tilt is too low or too high.
Size: 1 Byte, Default Value: 50

SettingDescription

1 – 100 Tilt Sensitivity

Parameter 255: Reset Parameter

0Nothing happens0x55555555Completely factory reset sensor and send device reset locally notification.All other valuesReset all Parameter settings to their default settings.
Size: 4 Byte, Default Value: 0

SettingDescription

1 – 1431655764 Reset all Parameter settings to their default settings.
1431655765 Completely factory reset sensor and send device reset locally

notification.

Parameter 3: Sensor State Polarity

This parameter defines the polarity of the magnet sensor.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Closed when Magnet near
1 – 0 Opened when Magnet near

Parameter 4: Visual LED Indications

This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life.
Size: 1 Byte, Default Value: 7

SettingDescription

0 LED indication Off
1 – 0 Open/Close Status Change
2 – 0 Wake Up
3 – 0 Open/Close Status Change + Wake Up (1+2 summarized)
4 – 0 Device Tampering
5 – 0 Open/Close Status Change + Device Tampering (1 + 5 summarized)
6 – 0 Wake Up + Device Tampering (2 + 4 summarized)
7 – 0 All LED indications on (values 1 + 2 + 4 summarized)

Parameter 5: Range Test after double click

Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Disabled
1 – 0 Enabled

Parameter 6: 2nd Association Group Trigger

This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Switch after Open and Close
1 – 0 Switch after Open
2 – 0 Switch after Close

Parameter 7: Command Sent to Devices of Association Group 2

This parameter defines which commands is sent to 2nd Association Group
Size: 1 Byte, Default Value: 2

SettingDescription

0 On
1 – 0 Off
2 – 0 On and Off

Parameter 8: BASIC command u0022On eventu0022 value

This is the BASIC command value sent in case of u0022Onu0022 event.
Size: 1 Byte, Default Value: 255

SettingDescription

0 – 99 Value
255 Value

Parameter 9: BASIC command u0022Off eventu0022 value

This is the BASIC command value sent in case of u0022Offu0022 event.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 99 Value
255 Value

Technical Data

Hardware Platform ZGM130
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.12.2
Certification ID ZC12-20080085
Z-Wave Product Id 0x0371.0x0102.0x000C
Color White
Z-Wave Scene Type Central Scene
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V2
  • Battery
  • Central Scene V3
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Notification V8
  • Powerlevel
  • Security 2
  • Sensor Binary V2
  • Supervision
  • Transport Service V2
  • Version V3
  • Wake Up V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>