Aeotec Water Sensor 7 Pro ZWA019-C Manual
- June 8, 2024
- Aeotec
Table of Contents
- Aeotec
- Water Sensor 7 Pro
- SKU: ZWA019-C
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 10: Time Delay of u0022Offu0022 command frame
- Parameter 11: Delay of Tamper Alarm Cancellation
- Parameter 12: Reporting Tamper Alarm Cancellation
- Parameter 16: Minimum Temperature change to report
- Parameter 17: Minimum humidity change to report
- Parameter 18: Temperature and Humidity Periodic Reports
- Parameter 255: Reset Parameter
- Parameter 3: Visual LED Indications
- Parameter 4: Range Test after double click
- Parameter 5: 2nd Association Group Trigger
- Parameter 6: Command Sent to Devices of Association Group 2
- Parameter 7: BASIC command u0022On eventu0022 value
- Parameter 8: BASIC command u0022Off eventu0022 value
- Parameter 9: Time Delay of u0022Onu0022 command frame
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aeotec
Water Sensor 7 Pro
SKU: ZWA019-C
Quickstart
This is a
secure
Alarm Sensor
for
.
Please make sure the internal battery is fully charged.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Water Sensor 7 pro brings more safety into your home. With its flexible sensor probe and the sensitive sensor point it detects the presence and absence of water at any given location. Furthermore the Watersensor 7 pro is enabled to accurately measure the temperature and humidity of its environment, so you are always informed about your room climate. Thanks to the latest Z-Wave 700 series technology, the Water Sensor 7 is distinguished with and increased range, S2 Security, OTA FW update and SmartStart.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Lifeline association to gateways |
---|---|---|
2 | 5 | Control devices when water leakage is detected |
3 | 5 | Sends out alarm message when water leakage is detected |
4 | 5 | Sends out alarm messages when tamper is tripped |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 10: Time Delay of u0022Offu0022 command frame
Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32400 | seconds |
---|
Parameter 11: Delay of Tamper Alarm Cancellation
Time a tamper alarm is delayed.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32400 | seconds |
---|
Parameter 12: Reporting Tamper Alarm Cancellation
This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Do not send Report |
---|---|
1 – 0 | Send Report |
Parameter 16: Minimum Temperature change to report
This value defines the minimum change of temperature to cause an unsolicited
report of humidity to the central controller using Lifeline.If the value is
set to 0, there will be no reports sent to the controller, when the
temperature changes. However, periodic reports, managed by configuration
parameter 18, may still be active.
Size: 1 Byte, Default Value: 20
SettingDescription
0 | Disabled |
---|---|
1 – 100 | 1/10 degree |
Parameter 17: Minimum humidity change to report
This value defines the minimum change of humidity to cause an unsolicited
report of humidity to the central controller using Lifeline.If the value is
set to 0, there will be no reports sent to the controller, when the humidity
changes. However, periodic reports, managed by configuration parameter 18, may
still be active.
Size: 1 Byte, Default Value: 5
SettingDescription
0 | Disabled |
---|---|
1 – 20 | % |
Parameter 18: Temperature and Humidity Periodic Reports
This parameter defines the time interval to send an unsolicited report.If
the value is set to 0, there will be no periodic reports sent to the
controller. However, reports on temperature/humidity changes, managed by
configuration parameters 16 and 17, may still be active.
Size: 2 Byte, Default Value: 43200
SettingDescription
0 | Disabled |
---|---|
900 – 65535 | Seconds |
Parameter 255: Reset Parameter
This parameter helps reset configuration parameters and the device to
factory defaults1 – 1431655764 (0x55555554) – Reset all Parameter settings to
their default settings.1431655765 – Completely factory reset sensor and send
device reset locally notification.
Size: 4 Byte, Default Value: 0
SettingDescription
1 – 1431655764 | Reset all Parameter settings to their default settings. |
---|---|
1431655765 | Completely factory reset sensor and send device reset locally |
notification.
Parameter 3: Visual LED Indications
This parameter defines when LEDs will indicate events. Disabling all
indications may extend battery life.Value 0 means – No Indications.
Size: 1 Byte, Default Value: 7
SettingDescription
1 – 0 | Water Leakage Status Change |
---|---|
2 – 0 | Wake Up |
4 – 0 | Device Tampering |
7 – 0 | All LED indications on (values 1 + 2 + 4 summarized) |
3 – 0 | Water Leakage Status Change + Wake Up (values 1 + 2) |
5 – 0 | Water Leakage Status Change + Device Tampering (values 1 + 4) |
6 – 0 | Wake Up + Device Tampering (values 2 + 4) |
Parameter 4: Range Test after double click
Allows to enable the activation of a Z-Wave range test with double clicking
the tamper switch.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disabled |
---|---|
1 – 0 | Enabled |
Parameter 5: 2nd Association Group Trigger
This parameter defines the status of the magnet switch that causes sending a
BASIC command to all devices of Association Group 2.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Switch after Water Leakage Start and Stop |
---|---|
1 – 0 | Switch after Water Leakage Start and Stop |
2 – 0 | Switch after Water Leakage Start and Stop |
Parameter 6: Command Sent to Devices of Association Group 2
This parameter defines which commands is sent to 2nd Association Group
Size: 1 Byte, Default Value: 2
SettingDescription
0 | On |
---|---|
1 – 0 | Off |
2 – 0 | On and Off |
Parameter 7: BASIC command u0022On eventu0022 value
This is the BASIC command value sent in case of u0022Onu0022 event.
Size: 1 Byte, Default Value: 255
SettingDescription
0 – 99 | Value |
---|---|
255 | Value |
Parameter 8: BASIC command u0022Off eventu0022 value
This is the BASIC command value sent in case of u0022Offu0022 event.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 99 | Value |
---|---|
255 | Value |
Parameter 9: Time Delay of u0022Onu0022 command frame
On command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32400 | seconds |
---|
Technical Data
Hardware Platform | ZGM130 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 0.00 |
Z-Wave Version | 7.12.2 |
Certification ID | ZC12-20060068 |
Z-Wave Product Id | 0x0371.0x0002.0x0013 |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info V3
- Association V2
- Battery
- Configuration V4
- Device Reset Locally
- Firmware Update Md V5
- Indicator V3
- Manufacturer Specific V2
- Multi Channel Association V3
- Notification V8
- Powerlevel
- Security 2
- Sensor Multilevel V11
- Supervision
- Transport Service V2
- Version V3
- Wake Up V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.