LEEDARSON Motion Sensor Pet Immunity Z-Wave 700 7CA-SS-VE-C0 Manual

June 8, 2024
LEEDARSON

LEEDARSON

Motion Sensor Pet Immunity Z-Wave 700

SKU: 7CA-SS-VE-C0

Quickstart

This is a
secure
Alarm Sensor
for
.

Please make sure the internal battery is fully charged.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The Motion Sensor lets you know when movement is detected in a certain area and can trigger different actions in response to that movement(or lack of movement). It supports the pet immunity up to 80 lbs.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 5| This is the Lifeline group; the commands listed below will be sent to the node(s) in this group in response to lifeline notification events.
---|---|---
2| 5| this is the on/off control group; the command listed below will be sent to the nodes in this group in response to on/off control event.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 10: LowBatPrecent

Low battery power level of alarm threshold values: the value range are 5~50 for percentage, the battery lowpower level can setting 5%~50%.
Size: 1 Byte, Default Value: 10

SettingDescription

5 – 50| 5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is less than 5%. the value 50 means 5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is more than 50%.
---|---

Parameter 12: Pironoff

Enable/Disable the PIR0 = Disable the PIR.1 = Enable the PIR.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 1| the value 0 means to disable the PIR. the value 1 means to enable the PIR.
---|---

Parameter 13: PirTimeout

Setup the wait time of PIR for clear the motion.Valid values: 0x05~0x3BC4
Size: 2 Byte, Default Value: 60

SettingDescription

5 – 15300| The 0x05~0x3BC4 is a valid value range which could be used to set the PIR latency time to clear the previous data.
---|---

Parameter 14: BasicEnable

When the Motion Sensor is triggered, if this parameter is 0x01 then it will send Basic set command to group 1.0 = Don’t send.1 = Send.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 1| value 0 means that motion sensor won’t send basic set to group 1 when the PIR is triggered, while 1 means yes.
---|---

Parameter 15: BasicReverse

PIR triggers the correspondence between the value of the Basic set and the PIR state.-If this value is 0x00 :PIR triggers send the basic set with 0xFF, PIR alarm release send the basic set with 0x00.-If this value is 0x01 :PIR triggers send the basic set with 0x00, PIR alarm release send the basic set with 0xFF.Only value 0x00 and 0x01 is valid .
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 1| 0x00-PIR triggers send the basic set with 0xFF, PIR alarm release send the basic set with 0x00. 0x01-PIR triggers send the basic set with 0x00, PIR alarm release send the basic set with 0xFF.
---|---

Parameter 16: PirSensitivity

Motion detection sensitivity level is a value between 0 and 10. This value affects the amount of motion energy required to generate a motion event and also affects the detection range and angle.0 = Lowest Motion Sensitivity 10 = Highest Motion Sensitivity
Size: 1 Byte, Default Value: 9

SettingDescription

0 – 10 0 = Lowest Motion Sensitivity 10 = Highest Motion Sensitivity

Parameter 17: PirPetImmunity

Enable/disable pet immunity mode. This feature is lens dependent and detection range may be reducedwhen Pet Immunity is enabled.0 = Disable the pet immunity mode1 = Enable the pet immunity mode
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 1 0 = Disable the pet immunity mode 1 = Enable the pet immunity mode

Parameter 18: LightSensorSendType

Configure lightsensor to upload data form1=Upload lumens value.2=Upload day or night(By notification).3=Upload lumens and day/night .
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 3 1=Upload lumens value. 3=Upload lumens and day/night .

Technical Data

Hardware Platform ZGM130
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.12.2
Certification ID ZC12-20050060
Z-Wave Product Id 0x0300.0x0300.0x0042
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V2
  • Basic V2
  • Battery
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Multi Channel Association V4
  • Notification V8
  • Powerlevel
  • Security
  • Security 2
  • Sensor Multilevel V5
  • Supervision
  • Transport Service V2
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LEEDARSON User Manuals

Related Manuals