GENERAL REMARK
- The installation and maintena.x:e has to be carried out by qualified professionals or auttlOC’ized technicians.
- The manufacturer shall not be held responsible for any damage or malfunction caused by wrong instaftation Of failing to comply with of Dowin.g instructions included in this pamphlet.
- For more detailed installation and maintenance guideines. please re-fer to below chapters.
CAUTIONS
Before instalJing ttds water heater.check and confrrm that the earthing on the
supply sockat is reliably grounded. Othetwise, the electrical water heata, can
not be installed and used. Do not use extension boaros.
tocorrect inistalation and use of this electrical water heater may result in
serious injuries and loss of p,operty.
Special Cautions
-
The water heater is not intended for use by persons (including chidren) with reduced physical, sensory or mental capabilities, or lack of experiance and knowledge, unless they have been given Supervision or instructions Conceming use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the heater.
-
The wall in which tho olectrical water heater is installed must be able to bear the load more than two times of the heater filled fully with water without distortion and cracks. Otherwise, other strengthening measures must be adopted.
The supply socket must be earthed reliably. The installation height of the supply socket must not be lower than 1.6m. The rated current of the socket must not be lower than 16A. The socket and plug must be kept dry to prevent clectrical leakage. if the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be selected, and raptaced by the professional maintenance personnal. -
The maximum iniet water pressure is 0.5MPa: the mingmum inlet water pressure is 0.1MPa, if this is necessary for the correct operation of the appliance.
-
When using the heater for the first time (or the frst use after maintenance), tho heater can not be switched on until it has been filled fully with water. When filling the water, at least one of the outlet valves at the outiet of the heater must be opened to exhaust the air. This valve can be closed after the heater has been filled fully with water.
-
The pressure relief valve attached with the heater must be installed at the cold water inet of this heater. and make sure it is not exposed in the foggy. The water may be outfiowed from pressure relief valve, so the outfiow pipe must open wide in the as. In order to drain away the water inside the inner container, it can be drained away from the pressure release valve. Twist the thread screw of the pressure release vaive off, and lift the drain handle upwardsiSee Fig. 1) . The drainage pipe connected to the pressure release hole must be kept sloping downwards and in a frost-free environment. The water may drip from the discharge pipe of the pressure-retief device and that this pipe must be left open to the atmosphere.
-
During heating, there may be drops of water dripping from the pressure release hole of the pressure role! valve. this is a norma! phenomenon.
The pressure release hole shall not be blocked under no circumstances, otherwise, the heater may get damaged. even resulting in accidents. If there is a large amount of water leak, please contact customer care carter for repas. -
The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not be blocked.
-
Since the water temperature inside the heater can reach up to 758, the hot water must not be exposed to human bodies when it is initially used.
Adjust the water temperature to a suitable temperature to avoid scalding. -
If any parts and components of this electrical water heater are damaged please contact customer care center for repair.
PRODUCT INTRODUCTION
NOTE:
This manual is applicable to the storage et«;tric water heaters
manufacttKed by this company.
Technical Performance Parameters
Mudel| Volumen| Rated power (w)| Rated voltace(ACV)|
Rated pressure
(Mpa)| Rated Water Temperature
(ºC)| Rated Thermoestat
SET(ºC)| Protection Class| Waturproof Grade
---|---|---|---|---|---|---|---|---
ACRUPCO ID| 10| 2000| 220-240| 75| 65| 65| I| IPX4
Aqua’s° 15| 15| 2000| 220-240| 0,75| 75| 75| I| IPX4
Assays 33| 30| 2000| 220-240| 15| 75| 75| I| IPX4
Aquapro 10| 10| 2500| 220-240| 15| 65| 65| I| IPX4
Aquapro 15| 15| 2500| 220-240| 0.75| 75| 75| I| IPX4
Miss 33| 30| 2500| 220-240| 0,75| 75| 75| I| IPX4
Brief introduction of product structure
| 1OL| 15L| 30L
---|---|---|---
A| 324| 368| 440
B| 324| 368| 440
C| 315| 340| 420
D| 66| 66| 66
(Note :All dimenstion are in mm)
Internal Wire Diagram
UNIT INSTALLATION
Installation Instruction
- This electrical water heater shail be installed on a solid wall. If the strength of the wall cannot bear the load equal to two times of the total weight of the heater filled fully with water, it is then necessary to install a special support. Incase of hollow bricks wall, ensure to fill it with cement concrete completely.
- After selecting a proper location, determine the positons of the two install holes used for expansion bolts with hook (200mm), Make two holes in the wall with the corresponding depth by using a chopping bit with the Size matching the axpansion bolts attached with the machine, insert the screws, make the hook upwards, tighten the nuts to fix firmly, and then hang the electrical water heater on it (see Fig.2).
- Install lhe supply socket in the wall The requirements for lhe socket are as follows: 250\1/1 OA. single phase, Three electrodes. tt is recommended to placed lhe socket oo the right abow the heater. The height of the socket to the ground shall not be less lhan 1.8m (see F,g.3).
- If the bathroom is too smail, the heater can be installed at another piace.
However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location shall be as near as possidie to the heater.
Pipelines Connection
- The dimension of each pipe part is G1/2”.
- Connection of pressure relief valve with the heater on the inlet of the water heater.
- In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the heater must be added at the end of the threads to ensure ieak proof joints (see Fig.4).
- If the users want to realize a multi-way supply system, refer to the method shown in fig.5 for connection of the pipelines.
NOTE
Please be sure to use the accessories provided by our company to install thes
olectric water heater. This electric water heater can not be hung on the
support until it has been confirmed to be firm and reliable. Otherwise, the
electric water heater may drop off from the wail, resulting in damage of the
heater, even serious accidents of injury. When determining the locations of
the boit holes, it shall be ensured that there is a clearance not less than
0.2m on the right side of the electric heater, to convenient the maintenance
of the heater, if necessary.
METHODS OF USING
- First, open any one of the outlet valves at the outlet of the water heater, then, open the inet valve. The water heater gets filled with water. When water flows out of the outlet pipe at implies that the heater has been filed fully with water, and the outlet valve can be closed.
NOTE
During normal operation, the inlet vaive shail be always kept open.
- Insert the supply plug into the socket.
- If the indicator lights up. the thermostat will automatically control the temperature. When the water temperature inside the heater has reached the set temperature, it will switch off automatically, when the wator temperature falls below the set point the heater will be turned on automatically to restore the heating.
- Rotate the knob according to the marking on the knob to increase or decrease the sotting temperature.
- In a power-on stato,the machine is heating when the Powar indicator light is white. The Heating indicator light goes out when the heating process is finished, in the insulating state.
MAINTENANCE
WARNING : Do cut off power supply before maintenance. to avoid dangor like olectric shock.
- Check the power plug and outlet as often as possible. Secure electrical contact and also proper grounding must be provided. The plug and outlet must not heat excessively.
- Hf the heater és not used for a long time, especially in regions with low air temperature (below 0°C), it is nessary to drain water from the heater to prevent damage of the water heater, due to water freazing in the intemal tank. (Refer Cautions in this manual for the method to drain away the water from the inner container).
- DTo ensure long reliable water heater operation. it is recommended to reguiarty claan the internal tank and remove daposits on the olectric heating element of the water heater, as well as check condition (fully decomposed or not) of the magnesium anode and, if necessary, replace it with a new one in case of full decomposition. Tank cleaning frequency depends on hardness of water located in this territory. Cleaning must be performed by special maintenance services. You can ask the seller for address of the nearest service center.
- The water heater is equipped with a thermal switch, which cuts off power Supply of the heating element upon water overheating or its absence in the water heater. If the water heater is connected to the mains, but water is not heated and the indicator doesn’t ight up, then the thermal switch was switched off or not switched on.
To reset the water heater to the operating condition, it is necessary to:
1. De-energize the water heater, remove the plate of the sida/lower cover.
2. Press the button, located at the center of the thermal switch. see Fig.7:
3. If the button is not pressed and there és no clicking, then you should wait until the thermal switch cools down to the initial temperature.
WARNING :
Non-professionais are not allowed to disassemble the thermal switch to reset.
Plaase contact professionals to maintain. Otherwise our company will not take
responsibility if any quality accident happens because of this.
TROUBLESHOOTING
Failures | Reasons | Treatment |
---|---|---|
The heating indicator light is off. | Failures of the temperature controller. |
Contact with the professional personnel for repair.
No water coming out of the hot water outlet.| 1.The running water supply is
cut off.
2.The hydraulic pressure is too low.
3.The inlet valve of running water is not open.| 1.Wait for restoration of
running water supply.
2.Use the heater again when the hydraulic pressure is increased.
3.Open the inlet valve of running water.
The water temperature is too high.| Failures of the temperature control
system.| Contact with the professional personnel for repair.
Water leak.| Seal problem of the joint of each pipe.| Seal up the joints.
NOTE
Parts illustrated in this use and care manual aro indicative only, parts
provided with the product may differ with ifustrations. This product is
intended for household use only. Specifications are subject to change.
WARRANTY STATEMENT
The product has all prescribed and declared properties. All mechanical
parts have a 2-year warranty, electric components and electric heaters 1 year,
while following the rules from the instructions. The warranty card 6 valid
with the attached invoice. During the warranty period, everything will be
removed free of charge, meaning defects resulting from poor material,
worlgnanship, defect or deficiency. We reserve the right to repair or replace
the entire product. No warranty covers damages caused by improper use,
formal wear and tear and errors that do not affect the value, functionality
and safety of the device. The warranty ceases to be valid if the repair is
carried out by an unauthorized person or if no original replacement parts were
used during the repair. Cleaning of scale deposits resulting from “hard” water
is not covered by the warranty and is not considered a manufacturing fault of
the product. For reflex damage (DAMNUM EXTRA REM), for actual property damage
or loss profit that could occur due to the use or lack of the product. we take
no reeponsibility. We also do not accept instalation costs and dismantiing and
amy other indirect or direct costs.
requirements for compensation for damages or compensation that would fall to
our burden due to eventualities complaint.
DISPOSAL AND RECYCLING
Important instructions for environment
Compliance with the WEEE Directive and Disposing of the Waster Product:
‘Thés product complies with EU WEEE Directive (2012/19/EU). This product bears
a classification symbol for waster electrical and electronic equipment (WEEE).
****This symbol indicates that this product shall not be disposed with other
household wastes at the end of its service life. Used device must be returned
to official collection point for recyciing of electrical electronic devices.
To find these collection systems please contact to your local authorities or
retailer where the product was purchased. Each household performs important
role in recovering and recycling of old appliance.
Appropriate disposal of used appliance helps prevent potential negative
Consequences for the environment and human health.
Compliance with RoHS Directive
The product you have purchased complies with EU RoHS Directive (201
1/65/EU). It does not contain harmful and prohibited materials specified in
the Directive.
Package information
Packaging materials of the product are manufactured from recyclable materials
in accordance with our National Environment Regulations. Do not dispose of the
packaging materials together with the domestic or other wastes. Take them to
the packaging material collection points designated by the local authorities.
DATA PROTECTION NOTICE
For the provision of the services agreed with the customer, we agres to Comply
without restriction with all stipulations of applicable data protection taw,
in line with agreed countries within which services to the customer will be
delivered, as well as, where applicable, the EU General Data Protection
Regutation (GOPRA). Generally. our data processing is to fulfil our obligation
under contract with you and for product safety reasons. to safeguard your
rights in connection with warranty and product registration questions. In some
cases, but only if appropriate data protection is ensured, personal data might
be transferred to recipients located outside of the European Economic Area.
Produce information with EU regulation
The electrical storage water heater Terma Aquapro 10L, ispod, 1500W of the
company Midea was tested with a declared load profile of the size “XXS”
The product fulfills and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water healing energy efficiency of “bun32.44%
that correspond to the water heating efficiency dass “B” In accordance vath
Annex Il Enercy Efficiency Classes article 1 of the commission regulation (No
812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label.
Electricity consumption Qex: water heating energy efficiency ren and mixed
water at 40 V40The electrical storage water heater Terma
Aquapro 10L, nad. 1500W of the company Midea was tested with a declared load
profile of the size “XXS”
The product fulfils and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of Nw:=35.65% that correspond to
the water heating efficiency class “A”
In accordance with Annex I! Enercy Efficiency Classes article 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label.
Electricity consumption Qee: water heating energy efficiency nw. and mixed
water at 40 v40
The electrical storage water heater AQUAPRO 15/1500 UNDER SINK of the company
Midea was tested with a declared load profile of the size “XXS”
The product fulfills and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of Ta=32% that correspond to the
water heating efficiency class “B”
In accordance with Annex II Enercy Efficiency Classes article 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label.
Electricity consumption Qee: water heating energy efficiency Nw and mixed
water at 40 v40
The electrical storage water heater AQUAPRO 15/1500 ABOVE SINK of the company
Midea was tested with a declared load profile of the size “XXS”
The product fulfils and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of “wn=32% that correspond to the
water heating efficiency class “B”
In accordance with Annex il Enercy Efficiency Classes artide 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label.
Electricity consumption Qeec water heating energy efficiency nw and mixed
water at 40 v40
The electrical storage water heater AQUAPRO 30/1500 UNDER SINK of the company
Midea was tested with a dectared load profile of the size “S”
The product fulfils and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of T=32.02% that correspond to the
water heating efficiency class “C”
In accordance with Annex Il Enercy Efficiency Classes article 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label.
Electricity consumption Qee: water heating energy efficiency nw and mixed
water at 40 v40
The electrical storage water heater AQUAPRO 30/1500 ABOVE SINK of the company
Midea was tested with a declared load profile of the size “S”
The product fulfils and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of “we=32.19% that correspond to
the water heating efficiency class “C”
In accordance with Annex il Enercy Efficiency Classes artide 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the retated commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label.
Electricity consumption Qee: water heating energy efficiency nw and mixed
water at 40 v40
Produced for: Fero-Term d.0.0.
Gospodarska 17, Donji Stupnik, Zagreb
Web: www.foro-term.hr
E-mail: info@fero-term.hr
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>