Simon S100 Rocker for Roller Blind (Mexico) 10005080-13x Manual
- June 8, 2024
- Simon
Table of Contents
- Simon
- S100 Rocker for Roller Blind (Mexico)
- SKU: 10005080-13x
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Association LED
- Parameter 12: Behavior of LED in repose
- Parameter 13: Lock Input
- Parameter 14: Calibration
- Parameter 15: Reset Default
- Parameter 20: Identify
- Parameter 21: Device state
- Parameter 23: Calibration required
- Parameter 24: Operating Mode
- Parameter 27: Lock long press
- Parameter 4: UP Time
- Parameter 5: DOWN Time
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Simon
S100 Rocker for Roller Blind (Mexico)
SKU: 10005080-13x
Quickstart
This is a ****
Window Covering – Pos/End Aware
for
.
To run this device please connect it to your mains power supply.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 3| Z-Wave Plus LifelinePosition Report when Sunblind is stopped and is
changed:- % new position -> CC Basic, Basic Report, Value 0xXX from 0x00 to
0x63Calibration requirement change. (If device needs to be calibrated and is
Added into a Z-Wave network, it will report after receive an Association Set
of life line).- Calibration required -> CC Configuration, Configuration
Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration,
Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a
DEVICE-RESET-LOCALLY-NOTIFICATION is sent.
---|---|---
2| 20| CtrlWhen Touch area is detected o key is pressed without touch area
detection:CC Configuration, Configuration Get, Param 21 -> Sent if param 28
value is 0x00, there is only 1 device is associated and it is a Simon device.
Used to know the associated device state.CC Basic, Basic Get -> Sent if param
28 value is 0x00, there is only 1 device is associated and it is not a Simon
device. Used to know the associated device
state.COMMAND_CLASS_BASIC_REPORTAssociates are sent when the sunblind remains
stoped for 1.5s after changing positions.% New position -> CC Basic, Basic
Report, Value 0x00 – 0x63
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Association LED
Allows to turn ON or OFF the central LED
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Turns the LED OFF |
---|---|
255 – 0 | Turns the LED ON |
Parameter 12: Behavior of LED in repose
Sets the central led ilumination when the key is in repose state
Size: 1 Byte, Default Value: 0
SettingDescription
0 | LED OFF |
---|---|
255 | LED on at 20 percent of maximum level |
Parameter 13: Lock Input
Locks or Unlocks the direct control of the load
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Unlock the direct control of load. |
---|---|
255 | Lock the direct control of load |
Parameter 14: Calibration
Performs a device calibration
Size: 1 Byte, Default Value: 0
SettingDescription
255 | Sunblind starts its callibration process |
---|
Parameter 15: Reset Default
Resets groups, Z-Wave status, and some or all configurations depending on
the configuration value (write only)
Size: 1 Byte, Default Value: 0
SettingDescription
17170 | Parameters, except Lock long press are restored to default |
---|---|
39015 | Parameters, Groups, and Z-Wave status are restored to default |
Parameter 20: Identify
Allows to identify a product using its central LED (write only)
Size: 1 Byte, Default Value: 0
SettingDescription
255 | The central LED blinks for 5 seconds in order to identify the device |
---|
Parameter 21: Device state
Reports the actual state of the load
Size: 1 Byte, Default Value: 0
SettingDescription
45056 | LED OFF |
---|---|
45057 | LED ON |
45312 | LED OFF |
45567 | LED ON |
Parameter 23: Calibration required
Reports if calibration is required or not (read only)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Calibration is not required |
---|---|
255 | It is necessary to calibrate the curtain to work properly |
Parameter 24: Operating Mode
Changes operating mode between Windows shutter and Sunblind
Size: 1 Byte, Default Value: 255
SettingDescription
0 | Operating mode for Window Shutter |
---|---|
255 | Operating Mode for SundBlinds |
Parameter 27: Lock long press
Locks or unlocks the long press on the key
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Long press works as described previously |
---|---|
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a |
long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info.
Parameter 4: UP Time
Sets time it takes to pull up the blind (ramp time)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Instantly |
---|---|
1 – 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 – 255 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Parameter 5: DOWN Time
Sets time it takes to pull down the blind (ramp time)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Instantly |
---|---|
1 – 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 – 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Window Covering – Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:75.53:66.47 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-20016843 |
Z-Wave Product Id | 0x0267.0x0004.0x0000 |
Neutral Wire Required | ok |
Window Covering Control Features | |
Firmware Updatable | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info V3
- Association V2
- Basic
- Configuration V2
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Powerlevel
- Switch Binary
- Switch Multilevel V3
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>