Heatit (Thermo-Floor) Heatit Z-Push Button 8 HEAE4512581 Manual

June 8, 2024
Heatit (Thermo-Floor)

Heatit (Thermo-Floor)

Heatit Z-Push Button 8

SKU: HEAE4512581

Quickstart

This is a
secure
Wall Controller
for
Europe
.

To run this device please insert fresh *1 CR2450** batteries.

Please make sure the internal battery is fully charged.

1. Turn on your Push Button.

2. Activate adding mode on your Z-Wave controller.

3. Activate adding mode of your Push Button by pressing and holding down both I and O of Group 2 for 3 seconds.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. Although it is controlling other devices, the device cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be added into the aZ-Wave network. The remote control has the following functions:”
1. Control of groups of other Z-Wave devices using ON, OFF and Dim commands.
2. Activation of scenes in Gateway mode.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Press and hold down both buttons I and O of Group 2 for a minimum of 10 seconds until the LED indicator turns on and then blinks 4 times quickly to indicate successful factory reset.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used.
Do not mix batteries of different charging level or different brands.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Press and hold down both buttons I and O of Group 2″ for 3 seconds. The LED indicator turns on, the Push Button will be set to adding mode, and stand by to be added to the network.

After 10s the LED indicator blinks 6 times quickly to indicate that the addition has been successful.

Exclusion

Press and hold down both buttons I and O of Group 2 for 3 seconds, LED indicator turns on, the Push Button will be set to removing mode, and stand by to be removed. After 7s the LED indicator blinks 4 times quickly to indicate successful removal.

Product Usage


Operation the device

– Push any button once or press and hold down any button to” send scene activation command to association Group 1 using” Command Class “”Central Scene Notification V3″”.

– Push I-/O-button of Group 2 once, to send ON/OFF command” to all associated devices of Association Group 2.”
– Press and hold down I-/O-button of Group 2, to send light” intensity increase/decrease command to all associated devices” of Association Group 2.

– Push I-/O-button of Group 3 once, to send ON/OFF command to all associated devices of Association Group 3.

– Press and hold down I-/O-button of Group 3, to send light” intensity increase/decrease command to all associated devices” of Association Group 3.

– Push I-/O-button of Group 4 once, to send ON/OFF command” to all associated devices of Association Group 4.

– Press and hold down I-/O-button of Group 4, to send light intensity increase/decrease command to all associated devices” of Association Group 4.

– Push I-/O-button of Group 5 once, to send ON/OFF command” to all associated devices of Association Group 5.

– Press and hold down I-/O-button of Group 5, to send light” intensity increase/decrease command to all associated devices” of Association Group 5

How to check if the push button has already been added to a network

Press any button once. If the LED indicator does not turn on,” the Push Button does not belong to any network. If the LED” indicator turns on, it means that the Push Button has already” been added to a network. You must then run the removal” process (see “”Removing from a Z-Wave network”” in this guide)” before adding the device to your network.

Set association using the Push Button and the devices that” are to be controlled.

To control a Z-Wave device from the Push Button, the node ID of” this device needs to be assigned to one of the two association” groups. This is a three- step process:

a. ” Press and hold down both buttons I and O of Group 2 for” 3 seconds until the LED indicator turns on.

b. ” Push the I-button of any group once within 7s to associate” the device to this group. Push the O-button of any group once” within 7s to remove association of the device from this group.

c. ” Operate the device to be controlled to send Node” Information Frame (please refer to the device manual) within 10″ seconds, or set the device to exclusion mode within 10 seconds,” since it will send Node Information Frame in exclusion mode,” LED indications are as follows:

– LED blinks twice to indicate that the remote control failed to” add the associated device (the association group has already” added maximum quantity associated devices that it supports ).

– LED blinks 5 times to indicate that the remote control added” the associated device successfully.

– LED blinks 8 times to indicate that the remote control removed the associated device successfully.

To remove all associated devices in an association group in the push button directly

1. Press and hold down both buttons I and O of Group 2 over 3″ seconds, LED indicator turns on.

2. Click OFF button of any group on the Push Button 5 times continuously within 7 seconds to remove all associated devices of this group, LED indicator blinks 8 times to indicate that the associated devices are removed successfully.

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains
information about the device type and the technical capabilities. The inclusion and
exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node
Information Frame. To issue a NIF execute the following action:

Press and hold down both I- and O-buttons of Group 2 for 3 seconds.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time
to save battery life time. Communication with the device is limited. In order to
communicate with the device, a static controller C is needed in the network.
This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller,
communication may become impossible and/or the battery life time is significantly
decreased.

This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the desired
wakeup interval and the node ID of the controller. If the device was included by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please perform
the following action:

Push any button once to activate the Push Button for 3s, and press and hold down both the I- and O-buttons of Group 2 for 1 second to activate the Push Button for 7s.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 5| Lifeline 1. Send Command Class Device Reset Locally Notification V1 to associated devices of this group to report factory reset information when factory reset the Push Button. 2. When Push Button battery power value changes, send Command Class Battery Report V1 to associated devices of this group to report power value information. 3. Short press or press and hold any button to send scene activation command to the associated devices of this group using Command Class Central Scene Notification V3
---|---|---
2| 5|

Short press I /O button of Group 2 to send ON/OFF command to associated devices of this group using Command Class Basic Set V2.”  Press and hold down I / O button of Group 2 to send light intensity increase/decrease command to associated devices of this group using Command Class Multilevel V4.

3| 5|

Short press I /O button of Group 3 to send ON/OFF command to associated devices of this group using Command Class “”Basic Set V2″”. Press and hold down I / O button of Group 3 to send light intensity increase/decrease command to associated devices of this group using Command Class Multilevel V4.

4| 5|

Short press I /O button of Group 4 to send ON/OFF command to associated devices of this group using Command Class Basic Set V2. Press and hold down I / O button of Group 4 to send light intensity increase/decrease command to associated” devices of this group using Command Class Multilevel V4.

5| 5|

Short press I /O button of Group 5 to send ON/OFF command to associated devices of this group using Command Class “”Basic Set V2″”. Press and hold down I / O button of Group 5 to send light intensity increase/decrease command to associated devices of this group using Command Class Multilevel V4.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Factory Reset

Value=0x55AA, other values are invalid,factory reset the Remote Control
Size: 2 Byte, Default Value: 0

SettingDescription

21930 Factory Reset

Technical Data

Dimensions 71,2 x 71,2 x 13,6 mm
Weight 66 gr
Hardware Platform ZM5101
EAN 7071236014706
IP Class IP 20
Voltage 3V
Battery Type 1 * CR2450
Device Type Wall Controller
Network Operation Portable Slave
Z-Wave Version 6.71.03
Certification ID ZC10-19086706
Z-Wave Product Id 0x019B.0x0300.0xa305
Z-Wave Scene Type Central Scene
Firmware Updatable Updatable by Consumer by RF
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Central Scene V3
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Powerlevel
  • Security
  • Security 2
  • Supervision
  • Transport Service V2
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic
  • Switch Multilevel V4

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Heatit (Thermo-Floor) User Manuals

Related Manuals