Heatit (Thermo-Floor) Z-Temp2 HEAE4512666 Manual
- June 8, 2024
- Heatit (Thermo-Floor)
Table of Contents
- Heatit (Thermo-Floor)
- Z-Temp2
- SKU: HEAE4512666
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Node Information Frame
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Temperature/ Humidity report interval
- Parameter 2: Temperature delta value
- Parameter 3: Humidity delta value
- Parameter 4: Temperature offset settings
- Parameter 5: Humidity offset settings
- Parameter 6: Proximity sensor retrigger interval
- Parameter 7: Proximity sensorEnable / Disable
- Parameter 8: LED maximum brightness
- Parameter 9: LED turned on before timeout
- Parameter 10: Temperature Control Hysteresis
- Parameter 11: Minimum Temperature Limit
- Parameter 12: Maximum Temperature Limit
- Parameter 13: External Relay & Operating State update interva
- Parameter 14: Report when presence is detected
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Heatit (Thermo-Floor)
Z-Temp2
SKU: HEAE4512666
Quickstart
This is a
secure
HVAC-Thermostat
for
Europe.
Please make sure the internal battery is fully charged.
1. Install the batteries (as stated in the technical specification).
2. Install the device on a flat vertical surface” using screws or double- sided tape
3. Set the controller/gateway in add mode (security/non-security).
4. Press the link button 3 times in a rapid sequence.
5. The thermostat will display “INC” when the thermostat is successfully included.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Heatit Z-Temp2 is a battery-operated thermostat designed for usewith water based heating systems. Used in combination with theHeatit Z-Water regulator you can control your heating system with aZ-Wave primary controller/gateway with the use of Heatit Z-Water incombination with one or several Heatit Z-Temp2.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
By pressing and holding the link button for 20 seconds, the thermostat will perform a complete factory reset. rES will be displayed.
Installation
Use a large flathead screwdriver to remove the back cover.” Fix the unit to the wall by double-sided tape, screws or installed” on top of a Euro wall box.”
Make sure the mounting surface is clean and dry.”
Then install 3x AA batteries (alkaline) in the device”’s battery-holder.
Note: Be careful to when installing batteries, ensuring the polarity of” the batteries is in accordance with the printing in plastic.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Press the link button on the thermostat 3 times in a rapid sequence
Exclusion
Press the link button on the thermostat 3 times in a rapid sequence
Product Usage
Z-Wave Button
Water based heating
The thermostat uses temperature readings retrieved from the internal sensor. Heatit Z-Temp2 is designed to work together with water based heating solutions. Heatit recommends using Heatit Z-Temp2 together with Heatit Z-Water. These two products allow for an advanced water based heating solution by using a Z-Wave enabled controller. This is a “wire-free” solution which save both time and money. All the communication between Heatit Z-Temp2 and the controlled device is wireless. The range can be extended using Heatit Z-Repeater or any other device that supports routing. This makes our water based solutions a good addition to your existing or new home automation system.
Electrical heating
Heatit Z-Temp2 could also be used in situations where a traditional electrical thermostat is not suited. The battery-operated thermostat can be used together with Heatit Z-Relay or any other relay device installed in a remote location. Rehabilitation could be done using this solution to avoid unnecessary wiring.
Display
The main screen
The main screen displays measured temperature readout or relative humidity. You can switch between the humidity and measured temperature by pressing the center button while display is active.
The temperature and humidity can be calibrated using parameter 4 and 5 respectively. When childlock is active, there will displayed” a lock icon adjacent to the Celsius icon.
Secondary screen
This screen displays the setpoint temperature when the thermostat is in heating mode. When the thermostat mode is turned OFF, the thermostat will not use this display. To turn ON or OFF the thermostat you need to hold center button for 20 seconds, or use Z-Wave command Basic or Thermostat mode.
Connecting to an external relay
After the device is added to your Z-Wave gateway you will need to link the thermostat to the device that is going to control the heating. This is done by using association groups from the thermostat”’s root device (EP0) with Group 3 (ON/OFF Control) towards your actuator device (using Multichannel or Single channel, based on the controlled device type.
Hysteresis (DIF)
You can make changes to the hysteresis in the thermostat via the parameter. This means that you can changes the hysteresis from” 0,3″°C up to max 3,0″°C. Default is 0,5″°C.
Child Lock – LOC
By pressing Left and Right (down and up buttons for 10 seconds,” the
thermostat will display LOC. Child lock is now activated, and the lock icon
will be lit up when the display is active. Trying to make changes from the
display is not possible within this modus. Changes with the Z-Wave controller
is still possible. Refer to your primary controller/gateways user manual on
how to change the setpoint.”
Child lock is deactivated by pressing Left and Right (down and up)” buttons
for 10 seconds, the thermostat will display oPn. The lock symbol is no longer
lit when the display is active, and now you can make changes using buttons.
Standby and Main Screen
When the thermostat remains untouched for a while, it will automatically go to standby screen. Due to power saving settings, while in standby, the display will be turned off. The proximity sensor will activate the thermostat when proximity is sensed. You can also activate the thermostat manually by pressing any button.
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z-Wave device. It
contains
information about the device type and the technical capabilities. The
inclusion and
exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node
Information Frame. To issue a NIF execute the following action:
Press the link button on the thermostat 3 times in a rapid sequence
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Lifeline. Normally used by the Z-WaveController. |
---|---|---|
2 | 5 | Multilevel Sensor Report (internal measured temperate and measured |
relative humidity).
3| 5| Binary Switch Set (normally used to control external relays).
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Temperature/ Humidity report interval
Used to adjust the time between report interval for Temperature and humidity
reports.
Size: 2 Byte, Default Value: 900
SettingDescription
30 – 32767 | 30 to 32 767 seconds (Default 900) |
---|
Parameter 2: Temperature delta value
Temperature delta value.
Size: 2 Byte, Default Value: 10
SettingDescription
0 | Reporting temperate based on change is disabled |
---|---|
5 – 50 | 0.5 to 5C (Default 10, 1.0C) |
Parameter 3: Humidity delta value
Humidity delta value.
Size: 2 Byte, Default Value: 10
SettingDescription
0 | Reporting temperate based on change is disabled |
---|---|
5 – 50 | 5 to 50% (Default 10, 10%) |
Parameter 4: Temperature offset settings
Calibrate the internal sensor.
Size: 2 Byte, Default Value: 0
SettingDescription
-100 – 100 | -100 to 100C (Default 0, 0C) |
---|
Parameter 5: Humidity offset settings
Offsets the measured relative humidity.
Size: 2 Byte, Default Value: 0
SettingDescription
-100 – 100 | -10 to 10% (Default 0, 0%) |
---|
Parameter 6: Proximity sensor retrigger interval
Proximity sensor retrigger interval.
Size: 2 Byte, Default Value: 10
SettingDescription
2 – 270 | 2 to 270 seconds (Default 10, 10 seconds) |
---|
Parameter 7: Proximity sensorEnable / Disable
Choose if proximity sensor is used or not.
Size: 2 Byte, Default Value: 1
SettingDescription
0 | Disable |
---|---|
1 | Enable (Default) |
Parameter 8: LED maximum brightness
Adjust the backlight of LCD display.
Size: 2 Byte, Default Value: 50
SettingDescription
0 – 99 | 0 to 99% (Default 50, 50%) |
---|
Parameter 9: LED turned on before timeout
Adjust the time from proximity sensor / display touched until display goes
to sleep.
Size: 2 Byte, Default Value: 3
SettingDescription
3 – 300 | 3 to 300 secounds (Default 3, 3 seconds). |
---|
Parameter 10: Temperature Control Hysteresis
Adjust the delta values for the thermostat to turn on off heating.
Size: 2 Byte, Default Value: 5
SettingDescription
3 – 30 | 0.3 to 3C (Default 5, 0,5C) |
---|
Parameter 11: Minimum Temperature Limit
Set the minimum temperature limit.
Size: 2 Byte, Default Value: 50
SettingDescription
50 – 400 | 5 to 40C (Default 50, 5C) |
---|
Parameter 12: Maximum Temperature Limit
Set the maximum temperature limit.
Size: 2 Byte, Default Value: 400
SettingDescription
50 – 400 | 5 to 40C (Default 400, 40C) |
---|
Parameter 13: External Relay & Operating State update interva
Set time on how often the devices sends Binary Switch Set and thermostat
mode to gateway.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Sends only when changed (Default) |
---|---|
1 – 240 | 1 to 240 minutes + When changed |
Parameter 14: Report when presence is detected
Decides if the thermostat sends temperature when presence is detected.
Size: 2 Byte, Default Value: 0
SettingDescription
0| Do not report to gateway when presence is detected, only at interval.
(Default)
---|---
1| Send temperature report to gateway when presence is detected.
Technical Data
Dimensions | 86 x 86 x 25 mm |
---|---|
Weight | 175 gr |
Hardware Platform | EFR32Z |
EAN | 7071236015307 |
IP Class | IP 21 |
Voltage | 4,5 V |
Device Type | Thermostat – HVAC |
Network Operation | Listening Sleeping Slave |
Z-Wave Version | 7.11.1 |
Certification ID | ZC12-20050065 |
Z-Wave Product Id | 0x019B.0x0004.0x0204 |
Color | White |
Thermostat HVAC Systems Supported | Dual FuelHumidity ControlUniversal |
Thermostat Power Source | Battery |
Thermostat Modes | Heat |
Firmware Updatable | Updatable by Manufacturer |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Application Status
- Association Grp Info V3
- Association V2
- Basic V2
- Battery
- Configuration V4
- Device Reset Locally
- Firmware Update Md V5
- Indicator V3
- Manufacturer Specific V2
- Multi Channel Association V3
- Notification V8
- Powerlevel
- Protection
- Security
- Security 2
- Sensor Multilevel V5
- Supervision
- Thermostat Mode V3
- Thermostat Operating State
- Thermostat Setpoint V3
- Transport Service V2
- Version V3
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>