FIBARO Door/Window Sensor (all Colors) FIBEFGK-101-ZW5 Manual
- June 8, 2024
- FIBARO
Table of Contents
- Fibaro Group
- FIBARO Door/Window Sensor (all Colors)
- SKU: FIBEFGK-101-ZW5
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: OPERATION MODE
- Parameter 10: 2ND ASSOCIATION GROUP TRIGGERS
- Parameter 11: COMMANDS SENT TO 2ND ASSOCIATION GROUP
- Parameter 12: VALUE OF ON COMMAND FRAME SENT TO 2ND ASSOCIATION GROUP
- Parameter 13: VALUE OF OFF COMMAND FRAME SENT TO 2ND ASSOCIATION GROUP
- Parameter 14: TIME DELAY OF ON COMMAND FRAME
- Parameter 15: TIME DELAY OF OFF COMMAND FRAME
- Parameter 2: DOOR/WINDOW/ALARM STATUS
- Parameter 20: TYPE OF SENT ALARM FRAMES
- Parameter 3: LED INDICATIONS
- Parameter 30: DELAY OF TAMPER ALARM CANCELLATION
- Parameter 31: REPORTING TAMPER ALARM CANCELLATION
- Parameter 4: RANGE TEST AFTER DOUBLE CLICK
- Parameter 50: INTERVAL OF TEMPERATURE MEASURING
- Parameter 51: TEMPERATURE REPORT THRESHOLD
- Parameter 52: TEMPERATURE REPORTS INTERVAL
- Parameter 53: TEMPERATURE OFFSET
- Parameter 54: TEMPERATURE ALARM REPORTS
- Parameter 55: HIGH TEMPERATURE ALARM THRESHOLD
- Parameter 56: LOW TEMPERATURE ALARM THRESHOLD
- Parameter 70: SCENE ACTIVATION FUNCTIONALITY
- Parameter 71: ALARM BROADCAST
- Parameter 72: ASSOCIATIONS IN Z-WAVE NETWORK SECURITY MODE
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fibaro Group
FIBARO Door/Window Sensor (all Colors)
SKU: FIBEFGK-101-ZW5
Quickstart
This is a
secure
Alarm Sensor
for
EU.
To run this device please insert fresh *1 1/2 AA 3,5V** batteries.
Please make sure the internal battery is fully charged.
- Open the cover.
- Remove the battery blocker.
- Close the cover.
- Locate the sensor nearby the main Z-Wave controller.
- Set the main Z-Wave controller into learning mode (see main controllers operating manual).
- Quickly, triple click the TMP button located on the bottom of the casing.
- Wait for the device to be added to the system. Successful adding will be confirmed by the controller.
- Install the device using the attached self-adhesive pads.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
FIBARO Door/Window Sensor is a wireless, battery powered reed sensor
compatible with the Z-Wave Plus standard. Changing the devices status will
automatically send signal to the Z-Wave controller and associated devices.
Sensor can be used to trigger scenes and everywhere there is a need for
information about opening or closing of doors, windows, garage doors, etc.
Opening is detected by separating the sensors body and the magnet.
In addition the FIBARO Door/Window Sensor supports one DS18B20 temperature
sensor and has one potential free input. The FIBARO Door / Window Sensor is
available in seven colors: white, silver, black, ivory, cappuccino, truffle
and dark chocolate.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
- Take off the Sensor”s cover and remove battery.
- Install the battery while holding both TMP buttons (after mounting the device, one button is constantly pressed by the cover).
- Release the TMP button within 5 seconds.
- LED will blink 3 times to confirm launching of reset procedure.
- Reset procedure may last up to 30 seconds. Do not remove the battery until reset is complete.
- Reset will be confirmed by the six blinks of the LED.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
Temperature sensor
The DS18B20 temperature sensor may be installed anywhere where temperature readouts are necessary. If adequately protected, the DS18B20 sensor may be installed in humid conditions, under water, sealed in concrete or placed under the floor. CAUTION Connecting devices and sensors other than DS18B20 is not allowed. !
To activate the device with temperature measurement functionality:
- Open the cover.
- Connect the temperature sensor to terminals of the device according to the diagram:
- Add the device
- Install the device
Button or external sensor
Door/Window Sensor is equipped with a potential-free input. It allows to change device state using the external button or sensor through GND signal.
If the Door/Window Sensor will be used only as a binary sensor, do not install the magnet. To activate the device as a binary sensor:
- Open the cover.
- Connect the button or external sensor to terminals of the device according to diagram:
- Add the device if the device is not already added.
- In case of connecting external sensor modify advanced parameter no. 20 to match type of the sensor, then remove and re-add the device to the network.
- Install the device.
To install the Door/Window Sensor:
- Stick the included self-adhesive pads to the bottom of the device and magnet.
- Peel off the protective layer of the sticker.
- Stick the device onto the door/window frame.
- Stick the magnet onto the moving part of the door/window, no further than 5mm from the sensor.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Quickly, triple click the TMP button located on the bottom of the casing.
Exclusion
Quickly, triple click the TMP button.
Product Usage
Tamper (TMP) button: The Door/Window Sensor is equipped with a tamper switch
with two buttons.
First TMP button is located inside the device, pressed by the closed cover.
Second TMP button is located at bottom of the device, pressed by the surface
on which the device is mounted.
For the tamper switch to work one of the buttons must always be pressed!
When one of the buttons is released, the tamper alarm will be send to the
controller and associated devices. Additionally, tamper button allows to
control the device directly.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
FIBARO Door/Window Sensor will wake up at a defined time interval and will ALWAYS try to communicate with the main controller. Setting wake up interval to 0 disables sending Wake Up Notification frame automatically. There is a possibility to wake up the device manually by a single TMP button click.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| Z-Wave Plus Lifeline reports the device status and allows for assigning
single device only (main controller by default)
---|---|---
2| 5| Control is assigned to the device status – reed sensor and IN input
(sends Basic Set command frames)
3| 5| Alarm is assigned to the device status – reed sensor and IN input (sends
alarm command frames). Its value may be modified via advanced parameters.
4| 5| Sensor ZW3 is assigned to the device status – reed sensor and IN input
(sends Basic Set command frames). This group provides backward compatibility
with controllers not supporting Z-Wave+
5| 5| Tamper ZW3 is assigned to the TMP switch (sends alarm command frames).
This group provides backward compatibility with controllers not supporting
Z-Wave+.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: OPERATION MODE
Parameter defines device operation mode. CAUTION: Do not install the magnet
if the device is not used as a Door/Window Sensor,as it might lead to the
malfunction of the device.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Door/Window Sensor or external alarm sensor (type – see par. 20) |
---|---|
1 | External switch |
Parameter 10: 2ND ASSOCIATION GROUP TRIGGERS
Parameter defines events which result in sending on/off commands to devices
added to the 2nd association group. These commands are sent alternately to
switch the devices on and off. Commands represent the values of BASIC SET
command frames. Parameter is inactive in external button mode (parameter 1 set
to 1).
Size: 1 Byte, Default Value: 0
SettingDescription
2 | switch after closing |
---|---|
0 | switch after opening and closing |
1 | switch after opening |
Parameter 11: COMMANDS SENT TO 2ND ASSOCIATION GROUP
Command frames sent to devices added to the 2nd association group.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | ON |
---|---|
1 | OFF |
2 | ON and OFF |
Parameter 12: VALUE OF ON COMMAND FRAME SENT TO 2ND ASSOCIATION GROUP
The value of 0 turns OFF the device, 255 turns it ON. In case of associating
the Dimmer or Roller Shutter module, values 1-99 allow to set an associated
device to a specified level.
Size: 2 Byte, Default Value: 255
SettingDescription
1 – 99 | Sets an associated device to a specified level. |
---|---|
255 | Turns ON the device. |
0 | Turns OFF the device. |
Parameter 13: VALUE OF OFF COMMAND FRAME SENT TO 2ND ASSOCIATION GROUP
The value of 0 turns OFF the device, 255 turns it ON. In case of associating
the Dimmer or Roller Shutter module, values 1-99 allow to set an associated
device to a specified level.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Turns OFF the device. |
---|---|
255 | Turns ON the device. |
1 – 99 | Sets an associated device to a specified level. |
Parameter 14: TIME DELAY OF ON COMMAND FRAME
Time period after which ON command frame will be sent.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32400 | time in seconds, max 9h |
---|
Parameter 15: TIME DELAY OF OFF COMMAND FRAME
Time period after which OFF command frame will be sent.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32400 | time in seconds, max 9h |
---|
Parameter 2: DOOR/WINDOW/ALARM STATUS
Parameter defines state of the sensor when the magnet is close. If you
connect the alarm sensor, it determines the output type. Parameter inactive in
Switch Mode (parameter 1 set to 1).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Door/window closed |
---|---|
1 | Door/window opened |
Parameter 20: TYPE OF SENT ALARM FRAMES
Type of control frames transmitted to the main controller and 3rd
association group – Alarm. If an external sensor is connected to IN input, it
is possible to choose its functionality. Otherwise it is recommended to set
this parameter to default value. CAUTION: In order to activate new settings of
parameter 20, it is required to remove and re-add the device to the main
Z-Wave controller. This parameter is not reset during removal process.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Door/Window Sensor (General Purpose Alarm) |
---|---|
1 | smoke sensor (Smoke Alarm) |
2 | CO detector (CO Alarm) |
3 | CO2 detector (CO2 Alarm) |
4 | high temperature sensor (Heat Alarm) |
5 | flood sensor (Water Alarm) |
Parameter 3: LED INDICATIONS
Paramater defines events indicated by the LED. Reducing number of them
results in longer battery lifetime. Default setting: 6 (indication of wake up
and device tampering). Parameter values may be combined, e.g. 1+2+4=7, means
that all indications are enabled.
Size: 1 Byte, Default Value: 6
SettingDescription
0 | no indications |
---|---|
1 | indication of opening/closing status change (input IN) |
2 | indication of wake up (1 x click or using time interval) |
4 | indication of device tampering |
Parameter 30: DELAY OF TAMPER ALARM CANCELLATION
Time period after which a tamper alarm will be cancelled.
Size: 2 Byte, Default Value: 5
SettingDescription
0 – 32400 | time in seconds, max 9h |
---|
Parameter 31: REPORTING TAMPER ALARM CANCELLATION
Reporting the cancellation of tamper alarm to 5th association group.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Do not send tamper cancellation report |
---|---|
1 | Send tamper cancellation report |
Parameter 4: RANGE TEST AFTER DOUBLE CLICK
Allows to enable activation of Z-Wave range test with double click of a TMP
button.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disabled |
---|---|
1 | Enabled |
Parameter 50: INTERVAL OF TEMPERATURE MEASURING
This parameter defines how often the temperature will be measured. The
shorter the time, the more frequently the temperature will be measured, but
the battery life will shorten.
Size: 2 Byte, Default Value: 300
SettingDescription
0 | temperature measurements disabled |
---|---|
5 – 32400 | time in seconds, 5 seconds – 9 hours |
Parameter 51: TEMPERATURE REPORT THRESHOLD
This parameter defines the change of temperature in comparison with last
reported, resulting in temperature report being sent to the main controller.
NOTE: Parameter 51 is active only if parameter 50 is not set to 0.
Size: 2 Byte, Default Value: 10
SettingDescription
0 | temperature reports based on threshold disabled |
---|---|
1 – 300 | temperature threshold (0.1-30 degrees Celsius, 0.1 degrees step) |
Parameter 52: TEMPERATURE REPORTS INTERVAL
This parameter determines how often the temperature reports will be sent to
the main controller. NOTE: Temperature measurement is performed before sending
any report (regardless of parameter no. 50). Excessive reporting can affect
battery lifetime. Reporting on the basis of temperature change (parameter no.
51) is recommended.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | periodic temperature reports disabled |
---|---|
5 – 32400 | time in seconds, 5 seconds – 9 hours |
Parameter 53: TEMPERATURE OFFSET
The value to be added to the actual temperature, measured by the sensor
(temperature compensation).
Size: 2 Byte, Default Value: 0
SettingDescription
-1000 – 1000 | -100 – 100 degrees Celsius, in 0,1 degrees steps |
---|
Parameter 54: TEMPERATURE ALARM REPORTS
Temperature alarms reported to the main Z-Wave controller. Thresholds may be
set in parameters no. 55 and 56.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | temperature alarms disabled |
---|---|
1 | high temperature alarm |
2 | low temperature alarm |
3 | high and low temperature alarms enabled |
Parameter 55: HIGH TEMPERATURE ALARM THRESHOLD
If temperature is higher than the set value, high temperature notification
will be sent and high temperature scene will be triggered (if activated).
Size: 2 Byte, Default Value: 540
SettingDescription
0 – 1000 | 0 – 100 degrees Celsius, in 0,1 degrees steps |
---|
Parameter 56: LOW TEMPERATURE ALARM THRESHOLD
If temperature is lower than the set value, low temperature notification
will be sent and low temperature scene will be triggered (if activated).
Size: 2 Byte, Default Value: 40
SettingDescription
-300 – 700 | -30 – 70 degrees Celsius, in 0,1 degrees steps |
---|
Parameter 70: SCENE ACTIVATION FUNCTIONALITY
The device can trigger scenes using scene IDs assigned to different events.
To deactivate all scenes set the value to 0. To activate all scenes set the
value to 3903. CAUTION: Every activated scene may shorten the battery life.
NOTE: Values of parameter 70 may be combined, e.g. 1+2=3 means scenes for
openingand closing are sent. NOTE: Scenes with IDs 12 to 15 are active only if
parameter 1 is set to 1. In this case scenes with IDs 1 and 2 are sent after a
single click.
Size: 2 Byte, Default Value: 0
SettingDescription
1 | [ID 10] opening door/window (single click) |
---|---|
2 | [ID 11] closing door/window (single click) |
4 | [ID 12] holding |
8 | [ID 13] releasing |
16 | [ID 14] double click |
32 | [ID 15] triple click |
256 | [ID 50] high temperature – door/window opened |
512 | [ID 50] high temperature – door/window closed |
1024 | [ID 51] low temperature – door/window opened |
2048 | [ID 51] low temperature – door/window closed |
Parameter 71: ALARM BROADCAST
Settings for broadcasting ON/OFF commands, sensor alarm and tamper alarm.
Value other than 0 means alarms are sent in Broadcast Mode, to all devices
only within the range of the device. They are not repeated by the mesh
network. NOTE: Values of parameter 71 may be combined, e.g. 1+2=3 means ON/OFF
commandsand sensor alarm are sent in Broadcast Mode.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | broadcasts inactive |
---|---|
1 | ON/OFF commands broadcast active |
2 | sensor alarm broadcast active |
4 | sensor alarm broadcast active |
Parameter 72: ASSOCIATIONS IN Z-WAVE NETWORK SECURITY MODE
This parameter defines how commands are sent in specified association
groups: as secure or non-secure. Parameter is active only in Z-Wave network
security mode. It does not apply to 1st group Lifeline. NOTE: Operating in
Z-Wave network security mode automatically disables sending alarms in
broadcast mode. NOTE: Values of parameter 72 may be combined, e.g. 1+2=3 means
2nd and 3rd group are sent as secure.
Size: 1 Byte, Default Value: 15
SettingDescription
0 | none of the groups sent as secure |
---|---|
1 | 2nd group, Control, sent as secure |
2 | 3rd group, Alarm, sent as secure |
4 | 4th group, Sensor ZW3, sent as secure |
8 | 5th group, Tamper ZW3, sent as secure |
Technical Data
Dimensions | 75 x 18 x 19 mm |
---|---|
Weight | 26 gr |
Hardware Platform | ZM5202 |
EAN | 5902020528364 |
IP Class | IP 20 |
Battery Type | 1 * 1/2 AA 3,5V |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 03.02 |
Z-Wave Version | 04.05 |
Certification ID | ZC10-15110001 |
Z-Wave Product Id | 0x010f.0x0b01.0x2002 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Zwaveplus Info
- Application Status
- Association
- Association Grp Info
- Basic
- Battery
- Configuration
- Crc 16 Encap
- Device Reset Locally
- Firmware Update Md
- Manufacturer Specific
- Multi Channel Association
- Alarm
- Powerlevel
- Security
- Sensor Alarm
- Sensor Multilevel
- Version
- Wake Up
- Multi Channel
Controlled Command Classes
- Basic
- Multi Channel
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>