Aeotec Micro Switch AEO_MES Manual Micro Switch

October 28, 2023
Aeotec

Aeon Labs

Micro Switch

SKU: AEO_MES

Quickstart

This is a ****

On/Off Power Switch
for
Europe
.

To run this device please connect it to your mains power supply.

Single click the button located near the Status Indication LED or alternatively press the external switch/ button control quickly 6 times to include or exclude the device. If the Aeon Labs Micro Switch is not included into any Z-Wave network, the LED will be blinking slowly continually.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The Aeon Labs Micro Energy Switch is a low-cost Z-Wave appliance switch specifically used to enable Z-Wave command and control (on/off) for existing in-wall switches. The wireless module is powered from the mains supply and is a three-wire design which requires a neutral connection. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Installation

The device is designed for a 3 wire system which requires a neutral connection. The module is powered from the main supply.

The schematic below shows how to wire the actuator. The power supply and the appliance are connected by the Load, Power Input and Neutral connectors. The 3.3 Volt and External Switch connectors are for external switching.

After the electrical installation the device has to be implemented in the Z-Wave Network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

To include the Aeon Labs Micro Switch with your Z-Wave controller simple bring it in the inclusion-mode and click the Inclusion/Exclusion button at the Aeon Labs Micro Switch once. Alternatively you can use the external switch by quickly pressing it six times. If the Aeon Labs Micro Switch was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) 10 seconds after the button was last pressed.

Exclusion

To include the Aeon Labs Micro Switch with your Z-Wave controller simple bring it in the inclusion-mode and click the Inclusion/Exclusion button at the Aeon Labs Micro Switch once. Alternatively you can use the external switch by quickly pressing it six times. If the Aeon Labs Micro Switch was successfully included to a Z-Wave network, the Status Indication LED will either be solid on or off (depending on if the switch is on or off) 10 seconds after the button was last pressed.

Product Usage

The switch is operated by an external switch/button or wireless. The click sets the switch on or off.

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains
information about the device type and the technical capabilities. The inclusion and
exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node
Information Frame. To issue a NIF execute the following action:

A single click at the Inclusion/Exclusion switch sends a Node Information Frame.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

2| 5|
---|---|---
1| 5|

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Type of Sensor Report

Defines the value type to be sent as Sensor Report.
Size: 1 Byte, Default Value: 00

SettingDescription

00 Power
01 Voltage

Parameter 2: Blinking Behavior

This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s.
Size: 2 Byte, Default Value: 0000

SettingDescription

Parameter 80: Notification on Status Change

Defines the automated status notification of an associated device when status changes
Size: 1 Byte, Default Value: 00

SettingDescription

00 Deactivated
01 Hail sent
02 BASIC Report Sent

Parameter 90: Disables Function of automated sending of a Report

triggered by minimal change of value.

__
Size: 1 Byte, Default Value: 00

SettingDescription

00 Disabled
01 Enabled

Parameter 91: Minimum Change to send Report (Watt)

The value represents the minimum change in Wattage for a Report to be sent .
Size: 2 Byte, Default Value: 0032

SettingDescription

00 – 3500 Value in Watt

Parameter 92: Minimum Change to send Report (%)

The value represents the minimum change in Wattage Percent for a report to be sent
Size: 1 Byte, Default Value: 0a

SettingDescription

00 – 100 Percentage

Parameter 101: Report type send in Reporting Group 1

Defines the type of report sent for the Reporting Group 1.
Size: 4 Byte, Default Value: 00000008

SettingDescription

Byte 1: 00000100 MultiSensor Report
Byte 1: 00001000 Meter Report for Watt
Byte 1: 00010000 Meter Report for kWh

Parameter 102: Report Type send in Reporting Group 2

Defines the type of report sent for the Reporting Group 2.
Size: 4 Byte, Default Value: 00000000

SettingDescription

Byte 1: 00000100 MultiSensor Report
Byte 1: 00001000 Meter Report for Watt
Byte 1: 00010000 Meter Report for kWh

Parameter 103: Report Type send in Reporting Group 3

Defines the type of report sent for the Reporting Group 3.
Size: 4 Byte, Default Value: 00000000

SettingDescription

Byte 1: 00000100 MultiSensor Report
Byte 1: 00001000 Meter Report for Watt
Byte 1: 00010000 Meter Report for kWh

Parameter 111: Send Interval for Reporting Group 1

Defines the time interval when the defined report of Reporting Group 1 is sent out.
Size: 4 Byte, Default Value: 000002d0

SettingDescription

00 – ffff Seconds

Parameter 112: Send Interval for Reporting Group 2

Defines the time interval when the defined report of Reporting Group 2 is sent out.
Size: 4 Byte, Default Value: 000002d0

SettingDescription

00 – ffff Seconds

Parameter 113: Send Interval for Reporting Group 3

Defines the time interval when the defined report of Reporting Group 3 is sent out.
Size: 4 Byte, Default Value: 0000ffff

SettingDescription

00 – ffff Seconds

Technical Data

Dimensions 0.0510000×0.0510000×0.0190000 mm
Weight 38 gr
Hardware Platform ZM3102
EAN 1220000011410
Voltage 230
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 03.00
Z-Wave Version 03.28
Certification ID ZC08-13030007
Z-Wave Product Id 0086.0003.001a
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Association
  • Version
  • Switch All
  • Scene Activation
  • Scene Actuator Conf
  • Configuration
  • Manufacturer Specific
  • Switch Binary

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.