ABUSHometec Z-Wave CFA3010 ABUECFA3010S Manual

June 8, 2024
ABUS

ABUS

Hometec Z-Wave CFA3010

SKU: ABUECFA3010

Quickstart

This is a
secure
Door Lock
for
Europe
.

To run this device please insert fresh *4 AA** batteries.

Please make sure the internal battery is fully charged.

Push the two arrow buttons for 3 seconds until the left green LED lights up. This indicates the management mode. Clicking on the “‘Lock”‘ button includes the device. The right green LED indicates readiness to include. Clicking the “‘unlock”‘ button will terminate the inclusion mode and also the management mode.” The device supports the Security S2 framework with Access Control network keys. To add the device using Security S2 framework locate the Device Key, located on the outlet cover of the device, and enter it, when asked by the controller, during the inclusion process. Please note that your gateway/controller MUST support S2 in order to use this product. If you own a legacy controller without Support for S2 please enable fallback to S0 security as described in Section “‘Installation”‘.

The device also supports Smart Start. Please scan the QR code on the outlet cover of the device and your controller will add the device automatically when powered up.
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The HomeTec Z-Wave wireless door lock actuator is a system designed for retrofitting to doors that open inwards to provide motorized locking and unlocking functions. The door can be electronically operated using local buttons and any Z-Wave device capable to control door locks. For the wireless door lock actuator to work, the cylinder must project 7-12 mm on the inside of the door (plus the thickness of the fitting or collar). Because the actuator operates with a key permanently inserted in the lock, the cylinder must have an emergency feature where the door can be opened with a key from the outside even when another key is inserted on the inside. In addition, the door lock must be a profile cylinder compliant with DIN 18252.” This device is security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.” This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

  • Enable management mode by holding down F1 and F2 for 3 seconds. Green left LED will light up to confirm management mode.

  • Move in this menu by pushing F1 or F2 Arrows. The left LED will change its color to indicate different menu items. left LED = green: Learn Mode,” left LED = red: Reset Mode __

  • Enter the menu, where left LED is RED, by pushing F1 or F2. __

  • Hit Enter (door close button). The right LED will change its color to indicate different reset options.
    right LED = green: Reset only Lock,
    right LED = yellow: Reset only Z-Wave,”
    right LED = red: Reset Lock and Z-Wave

  • Using the keys F1 and F2 you can change the setting. Change the setting to be RED (Reset Lock and Z-Wave) __

  • Push the Enter-button for 3 seconds until both LEDs are flashing. __

  • P ush the Enter-button again for 3 seconds to confirm the reset to factory default. __

All settings are deleted. Configuration parameters are NOT reset to default values. The user must explicitly reset them

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used.
Do not mix batteries of different charging level or different brands.

Installation

A particular plus point is that the device can be built in without needing to use a special cylinder. So you can integrate it into an existing locking system. The only requirement is that the door cylinder must be a cylinder with an emergency and danger function. This function is extremely important. As it ensures that you can unlock your front door with your normal house key when required. In addition, there should be a cylinder projection of at least 7 to max. 12 millimeters on the inside so that the HomeTec Pro can be built in quickly without any problems.

Enable Fallback to S0 Security

The device will not allow legacy security S0 on default. If you like to operate the device with a controller not supporting S2 security you need to enable fallback into S0.

  • Enable management mode by holding down F1 and F2 for 3 seconds. Green left LED will light up to confirm management mode.

  • Again pushing F1 and F2 for 3 seconds to enter Menu mode. Green left LED will blink to confirm.

  • Move in this menu by pushing F1 or F2 Arrows. The left LED will change its color to indicate different menu items.
    left LED = yellow: Speed settings,
    left LED = green: Power settings,”
    left LED = red: Z-Wave Security

  • Enter the menu, where left LED blinks RED, by pushing F1 or F2 Arrows.

  • Hit “Enter” (door close button). Now you will see the actual status of S0 fallback: right LED = red: S2+S0, right LED = green: S2 only

  • Using the keys F1 and F2 you can change the setting. Change the setting to be RED (S2 + S0)

  • Confirm selection with “Enter” (door close button)

  • Leave the menu by clicking “door open”. Leave the management mode by clicking “door open” again

Physical installation on the door

more information from ABUS Hometec original manual.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

  • Enable management mode by holding down F1 and F2 for 3 seconds. Green left LED will light up to confirm management mode.

  • Move in this menu by pushing F1 or F2. The left LED will change its color to indicate different menu items.
    left LED = green: Learn Mode,”
    left LED = red: Reset Mode __

  • Enter the menu, where the left LED is GREEN, by pushing F1 or F2 Arrows. __

  • Hit “Enter” (door close button).

  • Right LED will flash GREEN indicating readiness to include

Clicking the “unlock button, when Learn Mode is started, will terminate the inclusion mode and also the management mode.

Exclusion

  • Enable management mode by holding down F1 and F2 for 3 seconds. Green left LED will light up to confirm management mode.

  • Move in this menu by pushing F1 or F2. The left LED will change its color to indicate different menu items.
    left LED = green: Learn Mode,”
    left LED = red: Reset Mode __

  • Enter the menu, where the left LED is GREEN, by pushing F1 or F2 Arrows. __

  • Hit “Enter” (door close button).

  • Right LED will flash GREEN indicating readiness to exclude

Clicking the “unlock” button, when Learn Mode is started, will terminate the exclusion mode and also the management mode.

Product Usage

This door lock can be operated by a central Z-Wave enabled controller (using e.g. mobile phone), a dedicated Z-Wave remote control and from local buttons. Once installed. The Home Tec can turn the door lock to open and close. In parallel legacy operation using a key from the outside remains possible. The local buttons “door open” and
“door close”. accessible from the inside allows convenient locking and unlocking the key. It is possible to just close the door and really lock it up moving the deadbolt into the “close” position.”

The device sends the following notifications to the central controller:

  • Lock Jammed (0x06 – 0x0B)
  • Hardware Failure (0x09 – 0x01)
  • Motor Overcurrent (0x08 – 0x06)
  • Replace batteries (0x08 – 0x0B)

The Door Lock supports the following Door Lock Command Class modes:

  • Door Unsecured (0x00)
  • Door Unsecured with Timeout (0x01)
  • Door Secured (0xFF)

The Door Lock supports the following Door Lock Command Class Operation Types:

  • Constant Operation (0x01)
  • Timed Operation (0x02)

In Timed Operation only one Lock Timeout value is available: 30 seconds timeout. All the other timeout values are ignored.
By default the Door Lock has the following configuration:
Operation Type: Timed Operation (0x02)
Lock Timeout Minutes: 0x00
Lock Timeout Seconds: 0x1E (30)

The Door Lock can be operated:

  • Remotely using Z-Wave radio commands
  • Manually using Lock and Unlock buttons, located on the handle
  • Manually using the drive”‘s handwheel. This brings the lock to an “unknown” state and requires an additional open/close action using the Z-Wave radio commands or lock/unlock buttons
  • Manually using the key from outside. This brings the lock to an “unknown” state and requires an additional open/close action using the Z-Wave radio commands or lock/unlock buttons

Calibration procedure
After a reset procedure, the user must do the recalibration of the lock mechanism.
The calibration procedure must be performed, as described below. Otherwise correct behavior of the device is not guaranteed.
To calibrate the door lock:

  • Physically open the door, where Door Lock is mounted
  • Enable management mode by holding down F1 and F2 for 3 seconds. Both LEDs will start blinking yellow, indicating, that lock awaits calibration procedure
  • Hit “Enter” (button with closed door symbol).
  • The lock will start open/close calibrating procedure, which takes about 3-10seconds. Both LEDs will continue blinking yellow
  • Physically close the door, where Door Lock is mounted
  • Hit “Enter” (button with closed door symbol).
  • The lock will start open/close calibrating procedure, which takes about 3-10seconds.
  • Both LEDs should stop blinking yellow and become idle. If LEDs are still blinking, retry the calibration procedure

Troubleshooting

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Firmware-Update over the Air

This device is capable of receiving a new firmware ‘over the air’. The update function
needs to be supported by the central controller. Once the controller starts the update
process, perform the following action to confirm the firmware update:

  • LEDs will blink, indicating “wait for confirmation”
  • Push the Enter-button for 3 seconds until both LEDs are flashing yellow to confirm the Firmware update procedure.

If/when completed successfully (Firmware Update procedure might take up to 10 minutes) the LEDs will blink GREEN and return to normal operation.

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 5 Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Latch Hold Time

This parameter defines how long the latch is hold open when the door hall be opened.
Size: 1 Byte, Default Value: 3

SettingDescription

1 – 20 seconds

Parameter 2: Latch Torque

_ _This parameter defines the torque of the latch.__
Size: 1 Byte, Default Value: 2

SettingDescription

1 Torque of the latch is high (max.)
2 Torque of the latch is medium
3 Torque of the latch is low (min.)

Parameter 3: Acoustic Feedback

This parameter defines Acoustic Feedback signals.
Size: 1 Byte, Default Value: 3

SettingDescription

1 Acoustic signal is inactive
2 Acoustic signal only at the beginning of the lock travel
3 Acoustic signal when reaching the position of the event
4 Acoustic signal when reaching the position Locked
5 Acoustic signal when reaching each end position

Parameter 4: Travel Time

_ _This parameter defines the travel path of the Lock.__
Size: 1 Byte, Default Value: 1

SettingDescription

1 Automatic/Normal
2 Multiple turns for one Open/Close action
3 Travel from Tilted Position is turned on

Parameter 5: Touch Panel Settings

This parameter defines Touch Panel settings
Size: 1 Byte, Default Value: 1

SettingDescription

1 Touch Panel is active
2 Only Touch Panel Control Buttons are active
3 Touch Panel is inactive
4 Touch Panel Trap is inactive

Parameter 6: Motor Force

This parameter defines the motor force, when turning the lock.
Size: 1 Byte, Default Value: 1

SettingDescription

1 Automatic / Normal force
2 Maximum force

Parameter 250: Lock status

__
Size: 1 Byte, Default Value: 0

SettingDescription

0 unknown
1 open
2 unlocked
3 1x locked
4 2x locked
5 locked (end stop)
6 multiple interlocked

Parameter 251: Drive cycles Trap

Counter, how often” the trap is activated” was.
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 1670000 Counter

Parameter 252: driving cycles unlocked

Counter, how often in the direction of Unlocked navigated” was.
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 1670000 Counter

Parameter 153: Driving cycles interlocked

Counter, how often in the direction of Locked. navigated” was.
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 1670000 Counter

Parameter 254: ABUS Firmware Version

Display of ABUS Firmware version,” e.g. 1.05
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 65535 Version

Technical Data

Dimensions 138 x 51 x 66 mm
Weight 260 gr
Hardware Platform ZM5101
IP Class IP 20
Voltage 6V
Battery Type 4 * AA
Device Type Door Lock
Network Operation Listening Sleeping Slave
Firmware Version 1.0
Z-Wave Version 06.01
Certification ID ZC10-19076649
Z-Wave Product Id 0409.0005.0003
Color Silver
Door Lock Type Deadbolt Motor Attachment
Supported Notification Types Access ControlPower ManagementSystem
Firmware Updatable Updatable by Consumer by RF
Communications Protocol Manufacturer Proprietary Protocol
Security V2 S2_ACCESS_CONTROL
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Door Lock (s2 Access+s0)
  • Alarm (s2 Access+s0)
  • Association Grp Info (s2 Access+s0)
  • Device Reset Locally (s2 Access+s0)
  • Configuration (s2 Access+s0)
  • Manufacturer Specific (s2 Access+s0)
  • Powerlevel (s2 Access+s0)
  • Firmware Update Md (s2 Access+s0)
  • Battery (s2 Access+s0)
  • Association (s2 Access+s0)
  • Version (s2 Access+s0)
  • Multi Channel Association (s2 Access+s0)
  • Transport Service (required Security Class: None)
  • Zwaveplus Info (required Security Class: None)
  • Supervision (required Security Class: None)
  • Security (required Security Class: None)
  • Security 2 (required Security Class: None)

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.