LARK 83454 Kline 4 Light 25 Inch Black Chandelier Ceiling Light Instruction Manual

June 8, 2024
LARK

LARK 83454 Kline 4 Light 25 Inch Black Chandelier Ceiling Light

LARK-83454-Kline-4-Light-25-Inch-Black-Chandelier-Ceiling-Light-
PRODUCT

Mounting Instructions

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

DRAWING 1-STEM ASSEMBLY

  1. To begin installation it will be necessary to determine the desired height the pendant will be installed.
  2. The fixture is supplied with assorted stem sizes. Determine what combinations of stems are needed to achieve desired length see Drawing 1.
  3. Slip stems over wire and thread first stem onto top of pendant, longest stem first. Repeat this process until all required stems are threaded together.
  4. In the following order take retainer ring () and canopy (G) and slide them over the stems attached previously.
  5. Slip wire through center hole of swivel with flat plate (A), slip swivel and plate along wire, and thread into the top of the last stem installed.
  6. Attach universal mounting strap (B) to the junction box (J) with screws (C) not provided see Drawing 2.
  7. Slip holes (E) in mounting plate with swivel (A) over screws (D) in mounting strap (B).
  8. Thread ball knobs (F) onto screws (D) to secure fixture to universal strap (B).
  9.  All necessary wiring can be done at this time. Please follow I.S. 18 for wiring instructions.
  10. Slip canopy (G) up along rods (R) and over mounting plate with swivel (A).
  11. Slip retaining ring (L) up to canopy and thread onto coupler (K), located on the mounting plate and swivel assembly, to secure parts.

DRAWING 2- MOUNTING

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-TIONs (1.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

DRAWING 3-GLASS INSTALL

GLASS INSTALLATION

  1. To complete assembly, attach glass to fixture by first threading the socket ring (1), off of the socket – see Drawing 3.
  2. Next slip socket (S) through the small hole in the bottom of the glass (2). Let glass rest on glass fitter (3).
  3. Now thread socket ring (1) back onto socket, making sure the top of socket ring with the stamped thread is facing down toward the glass.

Drawing 1- Flush Mount

L.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEWw wIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

Drawing 2- Chain Hung

wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector- see Drawings 1 or 2.
  2. Connect negative supply wire () (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Drawing 3-Post-Mount

Outdoor Fixtures

  1. Connect positive supply wire A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 2 or 3.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  4. Please refer to the grounding instructions below to complete all electrical connections.

Grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) -see Drawing 1.

Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directhly to the ground wire of the building system with appropriately sized twist-on connectors -see Drawing 2.

Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.