CHILLOUT SYSTEMS Cypher Micro Cooler Installation Guide

June 8, 2024
CHILLOUT SYSTEMS

CHILLOUT-LOGO

CHILLOUT SYSTEMS Cypher Micro Cooler

CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(1\)

INCLUDED

  • 1x Cypher Micro Cooler
  • 1x Fluid kettle
  • 1x Carbon fiber baseplate
  • 2x Quick release pins
  • 1x Rubber isolaters

SPECIFICATIONS

  • RATED COOLING CAPACITY
    200 watts
    CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(2\)

  • WORKING VOLTAGE
    24V
    CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(3\)

  • MAX CURRENT
    7A
    CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(4\)

  • COMPRESSOR
    Micro Brushless Inverter
    Rated Voltage: 24V

  • FAN
    Axial Flow
    Rated Voltage: 24V

  • PUMP
    Rated Voltage: 24V
    Max Flow: 1.4L/min

  • SIZE
    Length: 7.63in / 194mm
    Width: 3.85in / 98mm

  • WEIGHT
    Cooler: 7.7lbs / 3.5kg

  • WATER TEMP SETTINGS
    Fahrenheit: 32°F, 65°F, 70°F
    Celsius: 0°C, 18°C, 21°C

  • OPERATING TEMPERATURE
    32°F – 130°F / 0°C – 54.4°C

  • STORAGE TEMPERATURE
    32°F – 140°F / 0°C – 60°C

PRODUCT OVERVIEW

CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(13\)

SYSTEM REMOTE

The Cypher Micro Cooler is controlled by the systems wired remote (included).

CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(14\)

BUTTON SETTINGS

  • ON/OFF
    Long press to turn the system On/Off.
    Short press to cycle through the systems four fan speeds.

  • MODE SELECTION
    Short press between three settings (Low, Medium, and High). The currently selected Air Volume is
    shown on the display. To return, wait 2 seconds and and short press again.

  • SWITCH TO EXTERNAL FAN
    While the system is OFF, long press MODE for 3 seconds. All three of the Air Volume lights will flash to
    confirm the system has switched to to an external fan mode.

  • SWITCH TO INTERNAL FAN
    While the system is OFF, long press MODE for 3 seconds. The Low Air Volume will flash once to confirm
    the system has switched to internal fan mode.

MOUNTING THE BASEPLATE

  • Determine the best location to mount your system inside the car. Keep your system away from any heat sources to ensure maximum cooling efficiency. Ensure there is a sufficient gap between the back of the unit so that the air can circulate freely.

Note: The Cypher Micro Cooler should be mounted in a horizontal state with a maximum tilt angle of 30°.

  • Using the systems baseplate as a guide, carefully outline the preferred install location.
  • Drill out the holes so that you can install the rivnuts to the vehicle. Once the rivnuts are installed, you can attach the base plate to the vehicle. Install the provided rubber isolators between the base plate and the installed rivnuts to keep airflow underneath the unit.

BATTERY TERMINAL LAYOUTS

Please use the following as a reference when advising the terminal layout required for your battery

  • When determining the terminal layout always face the terminal side (terminals closest to you) to avoid confusion / misinterpretation.

  • Once you figure out the length of wire required you can trim the excess and connect it accordingly. (Our wiring harness uses 8 AWG wire)

  • Connect the remote wire to the system if you have purchased a remote. We recommend putting the remote somewhere that sun won’t directly glare onto it (This can make it hard to read while driving).

FILLING THE KETTLE

The Cypher Micro Cooler comes with an external kettle for the fluid. The drivers shirt and kettle must be filled with fluid before the system is powered on.

  • Mix 1 part Chillout System’s Coolant Formula to 1 part deionized water (1:1)
    CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(19\)

  • Unscrew the lid of the kettle and pour in your fluid to just over 2/3’s of the kettles volume.

  • If you are using Propylene Glycol solution, the volume of concentration should not exceed 25%. If other antifreeze solution is used, its viscosity at 40°F / 25°C should not exceed 2.2mPa·s.
    Note: Purified water is also suitable fluid for the system if Chillout Systems Coolant Formula is not available.

  • When turning on the Cypher for the first time you will need to allow the internal pump cycle the fluid through the fluid lines. Before connecting to your shirt allow the system to cycle through and discharge the air in the tubing. This may take a few minutes.

CONNECTING THE SHIRT

  • If you are using a dual prong connector, run the insulated hose from the system to where the driver seat is, making sure there is enough slack to reach the drivers shirt comfortably.

  • If you are using Chillout System’s Rapid Release Kit, you can either cut and install it to a regular insulated hose or use Chillout System’s Insultated Y-Split Hose.

  • When using a Y-Split hose, we recommend keeping a dual prong connector on one side of the seat and installing the rapid release on the opposite side giving you both options in the car for connecting the shirts to the system.

CONNECTING AN EXTERNAL BLOWE

The Cypher Micro Cooler dual functionality with its internal fans or by adding the Cyphers 4 inch Top Mounted Plenum (sold seperately) and connecting an external 4” inch blower.

  • Remove the top mounted fans and attach the Cypher Top Mounted Plenum.

  • While the system is OFF, long press MODE for 3 seconds. All three of the Air Volume lights will flash to confirm the system has switched to to an external fan mode.

  • Connect the Plenum to the in-line blower using 4 inch neoprene ducting.

  • Place the NACA Duct and use marker or liquid chalk to trace an outline to the vehicle. Once the outline has been traced onto your window, a rotary cutting tool can be used to cut out the outline. We recommend using M4 nuts and bolts to secure the NACA duct to a lexan window.

DIMENSION

CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(23\)

CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(25\)

EXTEND YOUR PRODUCTS WARRANTY

Add Chillout Service to your purchase order adding an additional 2 years to your systems warranty (36 months total). This includes one free service at any time during the 36 month warranty period

SERVICING

  • Deep cleaning of all internals (includes fans, condenser, controller boards).
  • Servicing of the cooling system.
  • Freon pressure check and top-up (if necessary).
  • Performance checks and optimization.
    CHILLOUT-SYSTEMS-Cypher-Micro-Cooler-FIG- \(27\)

REPAIR/REPLACEMENT

In the unlikely event of a failure to your system, within your extended warranty we will expedite a replacement cooler to you via Express Air Service.

Your system will be diagnosed, serviced, repaired, and sent back to you.

REGISTER YOUR SYSTEM

To activate your warranty, scan the provided QR code or navigate to
https://chilloutsystems.com/pages/product-registration.
Products must be registered within 30 Days of purchase.