MOKO SMART LW005-MP LoRaWAN Smart Plug User Guide
- June 8, 2024
- MOKO SMART
Table of Contents
MOKO SMART LW005-MP LoRaWAN Smart Plug
About this Manual
The purpose of this manual is to outline how to use MKLoRa APP for LW005-MP parameters configuration.
MKLoRa APP
For the detailed operation of the MKLoRa app to configure and read device information, please refer to the following instructions:
Install MKLoRa APP
User can get the APP download link by search“MKLoRa”in your phone APP store:
Please allow Bluetooth to be enabled during the installation process. This APP
communicates with the device via Bluetooth, and it only supports above android
4.4 and IOS 9.0 system.
Note: After the successful installation of the APP, the APP will request
some mobile phone permissions, such as Bluetooth access permissions. Please
click “OK”, otherwise the APP will not work well.
Connect to LW005-MP
After the device is turned on, the device Bluetooth will start broadcasting.
Open the MKLoRa APP and choose LW005-MP on device option interface, then you
can search the LW005-MP device by click the refresh icon. The default
broadcast name of the device: LW005-MP-XXXX(XXXX is the last 4 bit of device
MAC address).
The Edit Filter at the top can help user filter the keywords and RSSI. RSSI
ranges from -127dBm to 0dBm;
- The distance between the phone and the device should be kept within 10m without wall obstruction. Otherwise, the device will not be searched. After searching for the device, click the “CONNECT” to connect the device that you want to configure.
- Then you should enter the password, the default login password is “Moko4321
Note : If a password is not entered within one minute, the login box will
disappear, you should click “CONNECT” again.
Note: If there is no action within 3 minutes after login, the system will
automatically login out.
Configure LW005-MP Parameters
When you log into the device successfully, you will enter the main page. There are four parts of the parameter configuration: LORA, GENERAL, BLUETOOTH and DEVICE
LORA Parameters
In this page, user can configure parameter for LoRa Part
- LoRaWAN Status: Indicates the status of the LoRaWAN network connection.
- Connection Settings: Configure LoRaWAN network parameters.
- Application Settings: Configure LoRaWAN application parameters
Connection Settings
- LoRaWAN Mode: LoRaWAN join-in mode selection
- DevEUI/AppEUI/AppKey: Network parameters in OTAA mode
- DevEUI/AppEUI/DevAddr/AppKey/NwkSKey: Network parameters in ABP mode.
- Region/Subnet : Device frequency band selection, AS923/ AU915 /CN470 /CN779 /EU433 /EU868 /KR920 /IN865 /US915 /RU864 can be set.
- Device Type: LoRaWAN device mode; it can be set Class A or Class C, the default is Class C.
- Message Type : Uplink payload type, it can be set unconfirmed or confirmed, the default is confirmed
- Advanced Setting: Some advanced parameter settings, if not necessary, it is not recommended to modify.
- Duty-Cycle : It is only used for EU868, CN779, EU433 and RU864. The default is off
- DR for join : It is only used for CN470, CN779, EU433, EU868, KR920, IN865, RU864. DR selection for Join Request of OTAA mode. The default is DR0, it ranges from DR0 to DR5
- CH: Channel Setting, Generally, the default is fine
- Uplink Strategy : Option1: ADR on, ADR mechanism following the standard protocol stack.
- Option2: ADR off. The device will choose the DR to send the payload within the set DR range, and will try to ensure that the time taken to send the payload is the same every time.
- Max retransmission times : Maximum number of retransmissions when selecting a confirmation frame to transmit an uplink Payload. The default is 3 times. The value ranges from 0 -7 times
Note: If the data length of the current payload exceeds the transmission
capacity of the selected DR, it will automatically make the DR plus one.
Note: Please do not modify advanced settings unless necessary
Application Settings
-
Time Sync Interval: It is used to sync the device time via MAC command. The default is 1, means that the device’s time will be synchronized every 1 hour via LoRaWAN MAC commands.
The value ranges from 0 -255H. 0 means disable. -
Network Check Interval : The device will periodically check the LoRaWAN network status via MAC command. The default is 1, means that the device will check the network status every 1 hour via LoRaWAN MAC commands.
-
The value ranges from 0 -255H. 0 means disable.
General Settings
In this page, user can configure general parameters
Switch Control
ON/OFF : User can control the AC output of the LW005-MP.
Report Interval: The report interval of switch payloads.
- The default is 30, the unit is s.
- The value ranges from 10 -600s
Electricity Settings
Report Interval : The report interval of electricity payloads. The default is 10, the unit is s. The value ranges from 5 -600s
Energy Settings
-
Report Interval: The report interval of energy payloads.
The default is 1, the unit is minutes. The value ranges from 1 -60 minutes. It can’t be less than Energy Save Interval. -
Energy Save Interval: The save interval of energy data.
The default is 1, the unit is minutes. The value ranges from 1 -60 minutes. -
Power Change Value : When the percentage change in power exceeds power change value, device will immediately store the energy data. The default is 15%, it ranges from 1% to 100%.
-
Total Energy: Historical total accumulated energy data of LW005
Protection Settings
When the plug detects that the measured voltage/current/power exceeds the safe
range for a period of time, it will automatically turn off the switch.
The rated current and voltage of different plug types are not the same, so the
power, voltage and current threshold configurations are also different, please
set the threshold value according to the plug types
Type | Parameter | Description |
---|
Over-load protection
|
Power threshold
| EU/FR plug: Default: 4416, range: 10-4416 (unit: W)
US plug: Default: 2160, range: 10-2160(unit: W)
UK plug: Default: 3588, range: 10-3588 (unit: W)
Time threshold| Default: 4, range: 1-30 (unit: second)
Over-voltage protection
|
Voltage threshold
| EU/FR plug: Default: 253, range: 231-264 (unit: V)
US plug: Default: 132, range: 121-138 (unit: V)
UK plug: Default: 253, range: 231-264 (unit: V)
Time threshold| Default: 4, range: 1-30 (unit: second)
Sag-voltage protection
|
Voltage threshold
| EU/FR plug: Default: 207, range: 196-229 (unit: V)
US plug: Default: 108, range: 102-119 (unit: V)
UK plug: Default: 207, range: 196-229 (unit: V)
Time threshold| Default: 4, range: 1-30 (unit: second)
Over-current protection|
Current threshold
| EU/FR plug: Default: 19.2, range: 0.1-19.2 (unit: A)
US plug: Default: 18, range: 0.1-18 (unit: A)
Load Status Notification
- Load Status : The load status of LW005-MP.
- Load Start Notification: When the plug detects that the load starts working, it will immediately report a notification to the server. The default is ON.
- Load Stop Notification: When the plug detects that the load stops working, it will immediately report a notification to the server. The default is ON.
- Load Status Threshold: The power when no load is connected to LW005-MP. The default is 0.5W. It ranges from 1-10, the unit is 0.1W.
Count Down Settings
Report Interval : The report interval of countdown payloads. The default is 10s, it ranges 10-60s.
LED Settings
On this page, you can set the power indicator color and the function switch of the two indicators. The max power of different plug types isn’t the same, so the configuration ranges of the power indicator is also different, please set the measured power value according to the plug types
Parameter | Description |
---|
Power indicator color
| Range: 0 – Active power indicator with color direct transition 1 – Active power indicator with color smooth transition
2 – White, 3 – Red, 4 – Green, 5 – Blue, 6 – Orange, 7 – Cyan, 8 – Purple
Default: 1- Active power indicator with color smooth transition
The measured power setting rules:
EU/FR plug:
1<= P(blue LED) <P(green LED)<P(yellow LED)<P(orange LED)
<P(red LED) <P(purple LED)<4416 US plug:
1<= P(blue LED) <P(green LED)<P(yellow LED)<P(orange LED)
<P(red LED) <P(purple LED)<2160 UK plug:
1<= P(blue LED) <P(green LED)<P(yellow LED)<P(orange LED)
<P(red LED) <P(purple LED)<3588
Network indicator status| The default is Enable, when it is disabled, the LED
will be OFF
Power indicator status| The default is Enable, when it is disabled, the LED
will be OFF
Bluetooth Settings
-
ADV Name : The advertising name of the device, up to 16 characters.
-
ADV Interval : Bluetooth advertising interval. The default is 1000ms. It ranges from 1-100, the unit is 100ms.
-
Connectable: User can select the connectable state or the unconnectable state. The default is connectable state.
When the device is on unconnectable state, the device only can be connected via Bluetooth in the first three minutes of power on. -
Login Password : Does the user need to enter the login password when using the app to connect to the device. The default is need.
-
Change Password: User can change the login password, up to 8 characters.
-
Tx Power : Bluetooth Tx power. The default value is 0 dBm and Tx Power can be configured as one of the following data:-40dBm,-20dBm,-16dBm,
Device Settings
Current Time Zone: Selection of the time zone in which the current device
is located.
The value ranges from UTC-12:00 to UTC+14:00, every half hour is a level. The
default time zone is UTC+8.
Device Information
- DFU (Update Firmware): To update the firmware via the DFU should use the upgrade package that MOKO provides with ZIP format.
- If you use an android phone, place the ZIP file of firmware upgrade package into the phone folder, select the upgrade package file from the OTA page of the APP, and click to upgrade.
- If you use an iPhone, user need to share the upgrade package file with
- MKLoRa via computers and iTunes tools. Then select the upgrade package file from the OTA page of the APP, and click to upgrade
Revision History
Version | Description | Editor | Date |
---|---|---|---|
1.0 | Initial version | Allen | 2021-12-20 |
MOKO TECHNOLOGY LTD.
4F,Buidling2, Guanghui Technology Park, MinQing Rd, Longhua, Shenzhen,
Guangdong, China Tel:86 755 23573370 829
Support_lora@mokotechnology.com
https://www.mokosmart.com
References
- Your IoT Devices ODM & JDM Partner - MOKOSmart #1 Smart Device Solution in China
- Your IoT Devices ODM & JDM Partner - MOKOSmart #1 Smart Device Solution in China
- Your IoT Devices ODM & JDM Partner - MOKOSmart #1 Smart Device Solution in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>