VERTICAL POWER VENT KIT
Note: Some models require a TCVT.PVKIT
For use with any TC Series “D” units, except for the TC54.
SKU# 22270013 3 – 110 FEET
INSTALLATION INSTRUCTIONS
Power Vent Characteristics
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference. These instructions are
supplementary to the Installation and Operating Instructions supplied with the
fireplace and should be kept together. Refer to the Installation and
Operating Instructions for proper gas supply, safety requirements and
operating instructions.
Locate the fireplace as per the main instructions supplied.
This installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural
Gas and Propane Installation Code, CSA B149.1.
All electrical installations should be performed by a qualified electrician to
the Canadian and U.S. National Electrical Codes (CSA C22.1 for Canada),
(ANSI/NFPA 70 for the U.S.) and/or local electrical codes.
Under no circumstances shall a rheostat be used to alter the voltage supply
to this unit.
This power vent is switchable from “Low” to “High”. The power setting must be
selected prior to operation.
For venting lengths between 3 & 25 feet, the switch must be set to “Low”.
For venting lengths between 26 & 110 feet, the switch must be set to “High”.
Dimensions
Venting Length
POWER VENT | 3 – 25’ | 26’- 110’ |
---|---|---|
TCVT.PVVT | LOW | HIGH |
Power Vents available by Model
(See TCVT.PVKIT installation instructions on page 12)
MODEL | TCVT.PVVT | TCVT.PVKIT REQUIRED |
---|---|---|
TC30.D | YES | |
TC36.DAR | YES | |
TC36.D | YES | |
TC36.DST | YES | |
TCWS.38D | YES | |
TC42.D | YES | |
TCWS.54D | YES | |
TCWS.54DST | NO | |
TCWS.54STOK | NO |
Venting Configurations
Maximum total vent length is 110 ft plus six 90-degree elbows or combination of other elbows equaling 90-degrees, with a maximum 66 foot vertical rise. Minimum total vent length is 3 ft. The vent can be installed with any combination of rise and run. Ensure vent pipe is properly supported and sealed.
Vent Terminal Clearance
Minimum clearances to combustibles Table
- Terminal casing: See Figure 4
- Vertical vent pipe: 1.5 in. (38mm)
- Horizontal vent pipe: 1.5 in. (38mm)
All other clearances are as per the fireplace installation instructions.
Minimum clearances to the vent terminal must be maintained as shown in (Figure
4). Measure clearances to the nearest edge of termination hood.
NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE DIFFERENT CLEARANCES. NOTE:
For flat roof installations, check local codes for elevated platform
dimensional requirements.
Figure 4: TCVT.PVVT Air exhaust clearances.
Note: Exhaust ports must face toward an open direction and not at another power vent or a wall within 4′. There can be a minimum of 1′ between power vents if their exhaust ports face away from each other and 1′ between a wall and the power 4′ vent if the exhaust is facing away from the wall.
Note: A site fabricated riser or standoff must be built to elevate this power vent from any surface where water or snow could accumulate at the power vents base if not using supplied riser. Consult local codes to determine the height of this chase or standoff.
Electrical Wiring Clearances
14-2 Electrical wiring must not be in contact with the vent pipe. There must be a minimum of 1 1/2 inches distance between the electrical wiring and the vent pipe
Vent Overlap at Terminal
Venting from fireplace to terminal must overlap enough so that the venting can be secured with screws. Tape over the joints using only the aluminum ducting tape supplied with the fireplace.
Securing the Power Vent to the Site Fabricated Riser
- Power Vent unit attaches to site fabricated riser at 3 points along each edge of the terminal base using installer supplied hardware. Terminal base attaches to supplied riser or site fabricated riser.
- Use Weather Sealant between the base of the power vent terminal and plates and the riser as necessary to prevent moisture from entering the power vent unit and building (Figure 8). Flash according to local codes.
TCVT.PVKIT Installation
This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent direct vent pipe, Selkirk Directtemp vent pipe or ICC Exceldirect vent pipe with a 5″ inner pipe and an 8″ outer pipe. For part numbers See “Venting Components” on page 18 of this manual. This vent can only be used as a vertically mounted roof termination.
-
Attach the vent adaptor directly to the appliance with the three screws (Figure 9) and seal outer pipe with aluminium tape provided.
Note: The inner pipe does not need to be sealed. -
Connect one of the high temperature silicone tubes to the upper pressure tap (marked “LOW”) on the adaptor (Figure 9). Secure with the hose clamp provided and route the tube through any hole back to the control box. This tube will be connected to the “low” side of the pressure switch inside the control compartment Connect the second tube to the lower pressure tap(marked “HIGH”) and route to the control box as before. Connect this tube to the remaining port on the pressure switch.
Tubes may touch unit and be trimmed if required.
Note: Ensure that there are no blockages in these tubes, as this will cause the control to malfunction. -
Locate the power vent termination following the clearance to combustible table, (See “Minimum clearances to combustibles Table” on page 7), venting configuration diagram and terminal location diagram (Figure 4 on page 7).
-
Seal and attach the power vent terminal base plate to the site fabricated chase as necessary to prevent moisture from entering the power vent unit. (Figure 5 on page 8) and flash according to local codes.
-
Run the required Simpson Duravent GS / Secure Vent / Selkirk Direct-temp or ICC Exceldirect pipe from the adaptor to the terminal assembly. Assemble as per the vent pipe manufacturer’s instructions including all shields and firestops.
NOTE: If this power vent is to be installed in a TC30 then it should use the full restrictor as shown in Figure 10. For all other units use the restrictor shown in Figure 11.
Pressure Switch Hose Connection
Attach the silicone tube from the upper pressure tap on the power vent adaptor (Figure 9 on page 12) to the “low” port of the pressure switch. Attach the other silicone tube from the lower pressure tap to the “high” port of the pressure switch (Figure 12).
Selecting Natural Vent and Power Vent Modes
The NV / PV (Natural Vent / Power Vent) switch (Figure 12) on the interface board (Figure 13) is set according to which type of evacuating vent system is present. If the fireplace is vented without the assistance of a power vent, the switch should be set to “NV”. If using a power vent, “PV” must be selected.
Important Note:
When switching between NV and PV, both the electrical power supply to the
fireplace must be turned off and the backup batteries removed to properly re-
set the module.
DO NOT install batteries into the wall switch while using a power vent.
Power Vent Wiring at Fireplace
Run a 14 – 2 wire from the fireplace to the power vent. Connect wires to the blue and white wires in the junction box.
Power Vent Wiring
The Power Vent assembly has an electrical connector block mounted internally. The external wiring from the main voltage/control module should be connected to this block. Follow the steps below to access this block.
- Remove the 4 hex screws holding the top cover in place (Figure 16) and remove the cover.
- Remove the internal cover plate (Figure 17)by removing 4 screws and slipping the plates slot around the motor wiring to remove. This exposes the electrical wiring entry point.
- Run the electrical supply wire from the fireplace up through the bottom of the power vent and to the connector block inside the power vent assembly (Figure 18). Connect wires as shown in Figure 19 and Figure 20. Connect ground to ground screw and tighten strain relief.
- Reposition Internal cover plate and blower cover and secure in place with previously removed screws.
Venting Components
SIMPSON DURAVENT COMPONENTS
Number…………………………….Description
1208…………………………………………..6″ Pipe Length
1207…………………………………………..9″ Pipe Length
1206…………………………………………12″ Pipe Length
1204…………………………………………24″ Pipe Length
1203…………………………………………36″ Pipe Length
1202…………………………………………48″ Pipe Length
1211……………………11″ to 14-5/8″ Pipe, Adjustable
1217………………………………. 4-10″ Pipe, Adjustable
1245………………………………………………… 45° Elbow
1290………………………………………………… 90° Elbow
1240….Round Ceiling Support /Wall Thimble Cover
1241…………………….Cathedral Ceiling Support Box
1242……………………………………………..Wall Firestop
1247…………………………………………….. Wall Thimble
1263………………………………………….Ceiling Firestop
1288………………………………………………… Wall Strap
SECURE VENT COMPONENTS
Number……………………………………….Description
SV5L6 ………………………………………………….. 6″ Pipe Length
SV5L12 ………………………………………………. 12″ Pipe Length
SV5L24 ………………………………………………. 24″ Pipe Length
SV5L36 ………………………………………………. 36″ Pipe Length
SV5L48 ………………………………………………. 48″ Pipe Length
SV5LA……………………………………………. 6″ Pipe, Adjustable
SV5LA12………………………………………. 12″ Pipe, Adjustable
SV5LA24………………………………………. 24″ Pipe, Adjustable
SV5E45…………………………………………….. Swivel 45° Elbow
SV5E90…………………………………………….. Swivel 90° Elbow
SV5CSB……….Adjustable decorative sq. cathedral support
SV5AC …………..Collar for decorative sq. cathedral support
SV5SU …………………………………………….. Universal support
SV5SD …………………………………………………… Floor support
SV5BM ………………………………………………………..Wall band
SV5RSA……………………………………….. Attic radiation shield
SV5RSM ………………………………………..Wall radiation shield
SV5BF ……………………………………………………………Firestop
SELKIRK DIRECT-TEMP
Number……………………………….Description
1605006…………………………………….. 6″ Pipe Length
1605009…………………………………….. 9″ Pipe Length
1605012…………………………………… 12″ Pipe Length
1605018…………………………………… 18″ Pipe Length
1605024…………………………………… 24″ Pipe Length
1605036…………………………………… 36″ Pipe Length
1605048…………………………………… 48″ Pipe Length
1605082………………………….. 4-10″ Pipe, Adjustable
1605215……………………………………………. 45° Elbow
1605230…………………………………………… 90° Elbow
1605424B ……… Cathedral ceiling support box (blk)
1605500…………………………………….Firestop spacer
1605460B ………………………………. Wall thimble (blk)
1605430……………………………….. Wall support band
ICC MODEL EXCELDIRECT
Number……………………………………….Description
TC-5DL6 ……………………………………………….6″ Pipe Length
TC-5DL1 ……………………………………………..12″ Pipe Length
TC-5DL2 ……………………………………………..24″ Pipe Length
TC-5DL4 ……………………………………………..48″ Pipe Length
TC-5DLF……………………………………….. 36″ Flexible Length
TC-5DLT ………………………12″ Pipe, Adjustable, Galvalume
TE-5DE45 ………………………… Swivel 45° Elbow, Galvalume
TE-5DE90 ………………………… Swivel 90° Elbow, Galvalume
TM-5SS …………………….Square Support / Radiation Shield
TM-5RDS………………….. Round Support / Radiation Shield
TM-5CS ……………………………….. Ceiling Support / Firestop
TM-OS………………………………………………….Offset Support
TM-SR ……………………………………………………Roof Support
TM-WS ……………………………………Adjustable Wall Support
TM-5WT……………………………………. Insulated Wall Thimble
TM-5TR …………………………………………….. Trim Ring, Black
TM-5AS ………………………..Attic Radiation Shield / Firestop
Wiring Diagram for Series “D” Fireplaces
Parts Diagram
© 2023 Copyright Pacific Energy Fireplace Products LTD
Reproduction, adaptation, or translation without prior written permission is
prohibited, except as allowed under the copyright laws.
Visit www.townandcountryfireplaces.com for the most recent version of this manual
For Technical Support, please contact your retailer.