GE APPLIANCES AHED05AC BTU Mechanical Window Air Conditioner Owner’s Manual

June 8, 2024
GE Appliances

GE APPLIANCES AHED05AC BTU Mechanical Window Air Conditioner

GE APPLIANCES AHED05AC BTU Mechanical Window Air
Conditioner

THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.

Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances product, and we think you will too. Among other things, registration of your appliance ensures that  wecan deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre- printed registration card included in the packing material.

SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal

  • Use this appliance only for its intended purpose as described in this Owner’s Manual.
  • This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
  • Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
  • Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end. Turn the unit OFF and unplug your air conditioner before cleaning.
  • For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
  • If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

WARNING Risk of Fire or Explosion. This unit contains flammable refrigerant. Additional safety precautions must be followed.

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
  • Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
  • Keep ventilation openings clear of obstruction.
  • When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing . Do not drill holes in the unit.
  • Maintenance, cleaning , and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants.
  • GE Appliances does not support any servicing of the air conditioner.
  • Dispose of air conditioner in accordance with Federal  and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.

WARNING USE OF EXTENSION CORDS RISK OF FIRE. Could cause serious injury or death

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
  • Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
  • Keep ventilation openings clear of obstruction.
  • When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing . Do not drill holes in the unit.
  • Maintenance, cleaning , and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants.
  • GE Appliances does not support any servicing of the air conditioner.
  • Dispose of air conditioner in accordance with Federal and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.

WARNING USE OF EXTENSION CORDS RISK OF FIRE. Could cause serious injury or death.

  • DO NOT use an extension cord with this Window Air Conditioner.
  • DO NOT use surge protectors or multi-outlet adaptors with this Window Air Conditioner.
HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance. The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

GE APPLIANCES

Controls

Air Conditioner Controls

Controls

  1. Temperature Control
    This determines how much cooling is provided.
    Max Cool – 10 provides the most cooling and
    Min Cool – 1 provides the least. Cooling Descriptions
    For Normal Cooling-Select 4 -7 on the dial with HCool r LCool selected.
    For Maximum Cooling-Select 8-10 on the dial with HCool selected.
    For Quieter and Nighttime Cooling-Select 1-3 on the dial with LCool selected.

  2. Mode Control HCool and LCool provide cooling with different fan speeds. HFan and LFan provide circulation and filtering without cooling.
    NOTE: If you move the Temperature control from a cool setting to a fan setting or power off the unit while cooling, wait at least 3 minutes before switching back to a cool setting.

Air Direction

Use the lever to adjust the air direction left to right.

Controls

Care and Cleaning

Do Not Operate in Freezing Outdoor Conditions

This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used when the outdoor temperature is below freezing (32°F) .

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Slide the filter from the left side of the unit. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

CAUTION
DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

Care and Cleaning

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

Care and Cleaning

Installation Instructions

IOuestions? Visit our Website at: GEAppliances.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local inspector’s use.
  • IM PO RT ANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
  • Completion time – Approximately 1 hour
  • We recommend that two people install this product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.
  • You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

ELECTRICAL REQUIREMENTS

These models require a 115/120-volt AC, \.V 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

CAUTION

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems-consult a qualified electrician.

TOOLS YOU WILL NEED

Tools You Will Need Phillips head screwdriver

|

Tools You Will Need Drill and 1/8″ drill bit

|

Tools You Will Need Pencil

---|---|---

Ruler or tape measure

|

Tools You Will Need Level

|

Tools You Will Need Scissors or knife

PARTS INCLUDED (Appearance may vary)

Type A (3)

|

Type B (9)

|

Side Brackets (2)

|

Window locking bracket (1)

---|---|---|---

WINDOW REQUIREMENTS

Installation Instructions

  • These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
  • The air conditioner can be installed without the side curtain panels if needed to fit in a narrow window. See the window opening dimensions.
  • All supporting parts must be secured to firm wood, masonry or metal.
  • The electrical outlet must be within reach of the power cord.
  • Follow the dimensions in the table and illustration for your model.
STORM WINDOW REQUIREMENTS

Installation Instructions

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2″
LENGTH: Long enough to fit inside the window frame.
THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2″ higher than the top of the storm window frame or the vinyl frame.
Attach securely with nails or screws provided by the installer.

PREPARE THE AIR CONDITIONE

A. Install the top mounting rail with 3 Type A screws
Installation Instructions

B. Slide the side curtain panels into the side panel rails.
Installation Instructions

C. Slide left and right side curtain frames into top and bottom rails. Make sure that side curtains snap into side of the frames.
Installation Instructions

INSTALL THE AIR CONDITIONER IN THE WINDOW

A. Measure the width of the window opening and mark the center line on the inside window sill. Place the unit in the window. Lower the window to hold unit in place.
Installation Instructions

B. Set the air conditioner in the window so that is centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.
Installation Instructions

C. Install the side bracket into the unit and into the window sill using two 1″ wood screws provided. repeate on other side.
Installation Instructions

D. Bring the window down so that the front edge of the top mounting is in front of the window. Make sure that the air conditioner is level or tilting slightly to the outside.
Installation Instructions

E. Extend the curtain panels until they fill the window. Mark the location of the holes in each corner. Use the drill and 1/8″ drill bit to drill pilot holes. Use 4 type B screws to secure the side panels in place.

INSTALL WINDOW LOCKING BRACKET AND FOAM TOP WINDOW GASKET

Use Type B Screw to install the window lock bracket on top of the bottom window.

A. CAUTION   Use Type B Screw to install the window lock bracket on top of the bottom window. To prevent broken glass or damage to windows, on vinyl or other similarly constructed windows, attach the window locking  bracket to the window side jamb with one Type B screw.
Installation Instructions

B. Cut the foam top window gasket to the window width.
C. Stuff the foam between the glass and the window to prevent air and insects from getting into the room.
Installation Instructions

NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.

Troubleshooting Tips … Before you call for service

Save time and money! Review the charts on the following pages first and you may not need to call for service.

Problem Possible Cause What To Do
Air conditioner does not start. The unit is unplugged. Make sure

the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.| Check the house fuse/circuit breaker box and replace the fuse or reset the bre aker.
Power Failure.| The unit will automatically restart in the setting last used after the power is restored .
There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.
The current interrupter device is tripped.| Press RESET button located on the power cord plug.
If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Air conditioner does not cool as it should.| Indoor airflow is restricted.| Make sure there are not curtains, blinds or furniture blocking the front of the air conditioner.
The temp control may not be set properly.| Turn the temperature control to a higher number.
The air filter is dirty.| Clean the filter at least every 30 days. See Care and Cleaning section.
The room may have been hot.| When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping.| Check for open furnace registers and cold air returns.
Cooling coils have iced up.| See “Air conditioner freezing up” below.
Air conditioner freezing up| Ice blocks the air flow and stops the air conditioner from cooling the room.| On models with control knobs, set the mode control at High Fan or High Cool with the Temp at 1 or 2.
Water drips outside| Hot, humid weather.| This is normal.
Water drips inside| The air conditioner is not tilted to the outside.| For proper disposal, make sure the air conditioner slants slightly from the case front to the rear.
Water collects in base pan| Moisture removed from air and drain into base pan.| This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas.

Normal Operating Sounds

Installation Instructions

  • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and off.
  • Water will collect in the base pan duringhigh humidity or on rainy days. The water may overflow and drip from the outdoor sideof the unit.
  • The fan may run even when the compressor does not.
  • Water droplets being thrown against the outside coils can make a pinging noise. This helps cool the condenser. You can reduce this noise by removing the subbase water plug.

To ensure maximum efficiency it is recommended to check to ensure the rubber drain plug is properly inserted. This plug may be removed during operation to minimize water in the back of the unit; however, removing it will lower the efficiency of your unit.
NOTE: Do not drill hole in the base pan.

Limited Warranty

Staple your receipt here. Proof of the original purchase date is needed to make a warranty claim.

For The Period Of: Will Replace:
One Year From the date oft he original purchase **Replacement, repair, or

refund** oft he original retail price for any product which fails due to a defect in materials or workmanship.  If the  unit is exchanged, the replacement  unit is warranted fort he remainder of your pro duct ‘s original one- year warranty period. GE will, at its sole discret ion, replace the product with a product of the same or comparable

functionality and quality or refund the original retail price.

In Order to Make a Warranty Claim During Your Retailer’s Allowable

Return Period

  • Properly pack your unit. We recommend using the original carton and packing materials.
  • Return the product tot he retail location where it was purchased.
  • Include int he package a copy oft he sales receipt or other evidence of date of original purchase. Also print your name and address and a description oft he defect.
In Order to Make a Warranty Claim During the Remainder of the One-Vear

Warranty

  • Locate your original sales receipt and make a note of your model and serial number.
  • Visit GEAppliances.com/ service to initiate the product replacement process . .
  • You will be asked to provide your name, address, date of purchase, model and serial number.
  • GE Appliances will arrange for a carton to be sent to your home to recover the product.
  • Please return all requested materials (postage pre-paid) in the carton provided. Please include a description of the defect.
  • You should receive your replacement product or refund within 7 to 10 business days after your package is received.
What Will Not Cover
  • Customer instruction. This owner’s manual provides information regarding operating instruct ions and user controls.
  • Improper installation. If you have an installation problem, or if the air conditioner is of improper capacity, cont act your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
  • Failure of the product resulting from modificationstothe product or duet o unreasonable use including failure to provide reasonable and necessary maintenance.
  • Replacement of house fuses or resetting of circuit breakers.
  • Failure duet o corrosion on models not corrosionprotect ed.
  • Damage tot he product caused by improper power supply voltage, accident, fire, floods or acts of God.
  • Incident al or consequential damage caused by possible defects with this air conditioner.
  • Damage caused after delivery.

EXCLUSION OF IMPLIED WARRANTIES- Your sole and exclusive remedy is product repair as provided int his Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.

For US Customers: This limited warranty is extended tot he original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not available, you may be responsible for at rip charge or you may be required to bring the product to an Authorized GE Appliances Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your home.
Some st ates do not allow the exclusion or limit at ion of incident al or consequential damages. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Consumer Support

GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support services designed for your convenience. In the US: GEAppliances.com

Register Your Appliance
Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material. In the US: GEAppliances.com/register

Parts and Accessories
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today 24 hours every day.
In the US: GEApplianceparts.com or by phone at 877.959.8688 during normal business hours.
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

Contact Us

If you are not satisfied with the service you receive from GE Appliances, contact us on our Website with all the details including your phone number, or write to:
In the US: General Manager, Customer Relations I GE Appliances, Appliance Park I Louisville, KY 40225 GEAppliances.com/contact

GE APPLIANCES  Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE Appliances User Manuals

Related Manuals