Laserliner 080.850A LaserRange-Master T4 Pro Distance Meter Instruction Manual

June 4, 2024
Laserliner

Laserliner 080.850A LaserRange-Master T4 Pro Distance Meter

Laserliner
080.850A LaserRange-Master T4 Pro Distance Meter PRODUCT

OVERVIEW

DIMENSIONS

Laserliner 080.850A LaserRange-Master T4 Pro Distance Meter
FIG 1 Laserliner 080.850A
LaserRange-Master T4 Pro Distance Meter FIG 2

NOTE: Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Function / Application
Compact laser distance meter for measuring length, area and volume – with Digital Connection interface and angle measurement function

General safety instructions

  • The device must only be used in accordance with its intendedpurpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • When using the device outdoors, make sure that the weather conditions are appropriate and/or that suitable protection measures are taken.
  • Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.

Safety instructions

Using class 2 lasersLaserliner 080.850A LaserRange-Master T4 Pro Distance
Meter FIG 3

  • Attention: Do not look into the direct or reflected beam.
  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Tampering with (making changes to) the laser device is not permitted.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Dealing with RF radiation

  • The measuring device is equipped with a wireless interface.
  • The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
  • Umarex GmbH & Co. KG hereby declares that the LaserRange-Master T4 Pro radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: https://laserliner.com/info?an=ACZ

Inserting batteries

Open the battery compartment and insert batteries (2 x typ AAA) according to the symbols. Be sure to pay attention to polarity.Laserliner 080.850A
LaserRange-Master T4 Pro Distance Meter FIG 4Laserliner 080.850A LaserRange-Master T4 Pro Distance Meter
FIG 5

DISPLAY:

  • Settings menu
  • Digital Connection function
  • Unit of measure
  • m / ft / inch /
  • Measurement point (reference) rear / thread / front
  • Continuous measurement / Length measurement
  • Pythagoras 1
  • Pythagoras 2
  • Area measurement
  • Volume measurement
  • Angle function 1
  • Angle function 2
  • Measured value, angle function Intermediate values Measurement values / Measurement results Unit m / ft / inch /

KEYPAD:

  1. Measure
  2. ON / OFF

Switch on, measure and switch off:Laserliner 080.850A LaserRange-Master
T4 Pro Distance Meter FIG 7

NOTE: After switching on, the device starts with continuous measurement.

Change unit of measure:
m / ft / inch / Laserliner 080.850A LaserRange-Master T4 Pro Distance
Meter FIG 8

Change measurement point (reference):
rear / thread / frontLaserliner 080.850A LaserRange-Master T4 Pro
Distance Meter FIG 9

Change measurement function:Laserliner 080.850A LaserRange-Master T4 Pro
Distance Meter FIG 10

Length measurement:Laserliner 080.850A LaserRange-Master T4 Pro Distance
Meter FIG 11

NOTE: After switching on, the device starts with continuous measurement.

Pythagoras function

Pythagoras function 1:Laserliner 080.850A LaserRange-Master T4 Pro
Distance Meter FIG 12

Pythagoras function 2:Laserliner 080.850A LaserRange-Master T4 Pro
Distance Meter FIG 13

Area measurement:Laserliner 080.850A LaserRange-Master T4 Pro Distance
Meter FIG 14

Volume measurement:Laserliner 080.850A LaserRange-Master T4 Pro Distance
Meter FIG 15

Angle function

Angle function 1:Laserliner 080.850A LaserRange-Master T4 Pro Distance
Meter FIG 16 The measurement results are determined automatically by the 360° inclination sensor.

NOTE: The back of the device can be used as a reference surface for measuring angles.

Angle function 2:Laserliner 080.850A LaserRange-Master T4 Pro Distance
Meter FIG 17

The measurement result is determined by the 360° inclination sensor.

NOTE: The back of the device can be used as a reference surface for measuring angles.

Data transfer

This device has digital connectivity which allows wireless data transfer to mobile devices such as smart phones or tablets with a wireless interface.
The system prerequisites for a digital connection are specified at https://packd.li/ll/bl2/v2
This device can generate a wireless connection to devices which are compatible with the wireless standard IEEE 802.15.4. The wireless standard IEEE 802.15.4 is a transfer protocol for Wireless Personal Area Networks (WPAN).
The range is set to a maximum distance of 10 m from the terminal device and greatly depends on the ambient conditions such as the thickness and composition of walls, sources of interference as well as the transmit / receive properties of the terminal device.

Enable / disable Digital Connection

Laserliner 080.850A LaserRange-
Master T4 Pro Distance Meter FIG 18

When enabled the Digital Connection symbol appears on the display. When the function is active, a mobile device can connect by means of an app to the measuring device.

Application (app)

An app is required to use the digital connection. You can download the app from the corresponding stores for the specific type of terminal device:Laserliner 080.850A LaserRange-Master T4 Pro Distance Meter FIG
19

NOTE: Make sure that the wireless interface of the mobile device is activated.

After starting the app and activating the digital connection, a connection can be set up between a mobile device and the measuring device.
If the app detects several active measuring devices, select the matching device.
This measuring device can be connected automatically the next time it is switched on.

Important notices

  • The laser points to the location that will be measured.
    No objects may get into the laser‘s line of measurement.

  • The device compensates the measurement for different room temperatures. Therefore allow the device a brief adaptation period when changing locations with large temperature differences.

  • The device is only conditionally useable in outdoor areas and cannot be used in strong sunlight.

  • The measurement results of outdoor measurements may be influenced or falsified by rain, fog and snow.

  • In unfavourable conditions, e.g. with poorly reflecting surfaces, the maximum deviation may be greater than 3 mm.

  • Carpeting, upholstery or curtains will not reflect the laser optimally. Measure to flat surfaces.

  • Measurements made through glass (window panes) can falsify measurement results.

  • An energy-saving function switches the device off automatically.

  • Clean with a soft cloth. Water may not be allowed to penetrate the housing.

Error codes:

  • Err204: Calculation error
  • Err208: Internal fault
  • Err220: Replace the battery
  • Err252: Temperature is too high: > 40°C
  • Err253: Temperature is too low: < 0°C
  • Err255: Received signal too weak or measuring time too long
  • Err256: Received signal too strong
  • Err261: Outside the measuring range
  • Err500: Hardware fault

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Calibration

The measuring device should be calibrated and tested on a regular basis to ensure it is accurate and working properly. We recommend the me-asuring device is calibrated every 1 – 2 years. If necessary, contact your distributor or the UMAREX-LASERLINER service department.

Technical Data

Technical Data (Subject to technical changes without notice. Rev22W03)|
---|---
Distance measurement|
Precision (typical)*| ± 2 mm
Measurement range (inside) | 0.2 m – 40 m|
Angle measurement**|
Measuring range| ± 90°
Resolution| 0.1°
Precision| 0.1°


Laser class

| 2 / < 1 mW

(EN 60825-1:2014/AC:2017/AC:2017)

Laser wavelength| 650 nm


Operating conditions

| 0°C … 40°C, max. humidity 85% rH, no condensation, max. working altitude 2000 m above sea level
Storage conditions| -20°C … 70°C, max. humidity 80% rH



Radio module operating data

| IEEE 802.15.4. LE ≥ 4.x (Digital

Connection) interface; Frequency band: ISM band 2400–2483.5 MHz, 40 chan- nels; Transmission power: max. 10 mW; Bandwidth: 2 MHz; Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS


Automatic switch-off

| Dynamic depending on measuring mode: Laser: 30 s – 5 min

Device: 3 min – 8 min

Power supply| 2 x 1,5V LR03 (AAA)
Dimensions (W x H x D)| 35 x 100 x 23 mm
Weight| 82 g (incl. batteries)

measuring distance up to 10 m with a strongly reflective target surface and at room temperature. The measurement deviation may increase by ± 0.2 mm/m for greater distances and under unfavorable measuring conditions such as strong sunlight or weakly reflective target surfaces.
at max. 5000 lux

EU and UK directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU and the UK.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: https://laserliner.com/info?an=ACZ

LaserRange-Master T4 ProLaserliner 080.850A LaserRange-Master T4 Pro
Distance Meter FIG 20

SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany Tel.: +49 2932 638-300, Fax: +49 2932 638-333 info@laserliner.com

Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333 www.laserliner.com