OSRAM Quicktronic T8 Instant Start High Efficiency Series UNV High Ambient Temp Systems User Guide
- June 8, 2024
- OSRAM
Table of Contents
T8 Instant Start High Efficiency Series UNV High Ambient Temp Systems
User Guide
Lamp/Ballast Guide
32W T8 – fluorescent lamps
2-lamp QHE 2x32T8 UNV ISH HT SC
3-lamp QHE 3x32T8 UNV ISH HT SC
Also operates:
FB32, FB31, F30/SS (30W), FB30/SS
(30W), FB29/SS (29W), F28/SS (28W)
& F25/SS (25W)
Key System Features
-
High Efficiency Systems over 90% efficient
-
90°C maximum case temp.
-
Lamp Striation Control (LSC)
-
Over 100 LPW (lumens/watt) with energy-saving lamps
-
Lowest power T8 PLUS Systems
-
Universal voltage (120-277V)
-
1.18-1.20 ballast factor
-
30-50% Energy savings
-
Min. Starting Temp:
• -20°F(-29°C) for T8 lamps
• 60°F (16°C) for Energy Saving T8 x lamps -
<10% THD
-
Virtually eliminates lamp flicker
-
RoHS compliant
-
Lead-free solder and manufacturing process
Application Information
QUICKTRONIC High Efficiency ballasts are ideally suited for:
- Any applications where the highest light output for the lowest amountpower T8 systems are needed formaximum energy savings
- High bay lighting
- Energy Retrofits
- Commercial & Retail
- Hospitality & Institutional
- New Construction
QUICKTRONIC High Efficiency (QHE) energy-saving electronic T8 ISH (PLUS) ballasts offer several advantages:
- Same Light, Less Power!
- Up to 6% in energy savings compared to standard T8 low power electronic ballasts without compromising light output.
- Maximum energy savings when compared to F40T12 magnetically ballasted systems
- High Light Output:
- Higher lumens per fixture
- Fewer fixtures required for same light output
- Parallel Circuitry: keeps remaining lamps life one or more go out.
- Lamp Striation Control (LSC): T8 energy saving lamps should be operated above 60°F, but under certain conditions the lamps may striate. LSC circuitry may minimize or eliminate this condition; however there are limited applications where LSC circuitry may not entirely mitigate lamp striations. These ballasts are also RoHS compliant and feature lead-free solder and manufacturing process.
- High Ambient Temp: specifically designed for those applications where the ballast is subject to higher ambient temperatures, such as high bays in industrial installations.
System Information
QUICKTRONIC High Efficiency (QHE) System advantages:
- Operate from 120V through 277V
- Eliminates “wrong voltage” errors
- Reduces inventory by 50%
- Utilizes Instant Start operation for
- Highest System Efficacy
- Low temperature starting capability
- Very low harmonic distortion (<10%)THD
- Operate at >42 kHz to reduce potential interference with infrared control systems
System Type| Input Power(W)| Initial System Lumens| System Efficacy LPW|
Mean System Lumens| Relative Mean
Light Output| Energy Savings
---|---|---|---|---|---|---
4:F34T12 – Two E.S. Magnetic Ballasts| 144| 9330| 65| 7930| Baseline| Baseline
4:FO32T8/700 – QTP 4x32T8 UNV ISN SC| 112| 9150| 82| 8415| 106%| 22%
3:FO32/XP ® – QHE 3x32T8 UNV ISH HT SC| 111/109| 10620| 96/97| 9985| 126%|
23%
3:FO28/SS – QHE 3x32T8 UNV ISH HT SC| 98/96| 9650| 98/101| 9070| 114%| 32%
2:FO32/XP – QHE 2x32T8 UNV ISH HT SC| 74/73| 7200| 97/99| 6770| 85%| 49%
2:FO28/SS – QHE 2x32T8 UNV ISH HT SC| 65/64| 6540| 101/102| 6150| 78%| 55%
SPECIFICATION DATA
Catalog # | Date | Type |
---|---|---|
Project | Prepared by | |
Comments |
High Efficiency, Lamp Striation Control, High Ambient (120-277V)
NAED in parentheses is provided as a cross reference for the new item number.
1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by
Input Power (Note: calculation based on lowest wattage value).
Dimensions “-SC” Small Enclosure:Overall: 9.5″ L x 1.68″ W x 1.18″ H
Mounting: 8.90″
Product Weight: 1.6 lbs each (approx.)
Wiring: Leads only
High Ballast Factor
T8 Instant Start
High Efficiency
Performance Guide
QUICKTRONIC ® QHE Instant Start ballasts are compatible with other lamp
manufacturers equivalent lamp types that meet ANSI specifications. QHE Instant
Start ballasts will operate F32 (and energy-saving & U-Bend equivalent) T8
lamps.
Specifications
Data based on F32T8
Starting Method: Instant Start
Ballast Factor: 1.18-1.20
Circuit Type: Parallel
Lamp Frequency: >42 kHz
Lamp CCF: Less than 1.7
Starting Temp:2-20°F (-29°C) for T8 lamps;60°F (16°C) for energy-saving T8
lampsInput Frequency: 50/60 Hz
Low THD: <10%
Power Factor: >98%
Voltage Range: ±10% of 120-277V rated line (108-305V)
UL Listed Class P, Type 1 Outdoor
CSA Certified
High Ambient Applications: 90°C Max. Case Temp. (3 yr. warranty)
Standard Ambient Applications: 70°C Max. Case Temp. (5 yr. warranty)
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
QUICKTRONIC 3×32
RoHS Compliant3
ANSI C62.41 Cat. A Transient Protection.
GFCI compatible
Emergency ballast compatible.
Remote Mounting (Max. wire length from ballast case to lampholder):
- 20 ft: full wattage T8s
- 10 ft: energy saving T8s
- 4 ft: 25W energy saving T8
2 Operation below 50°F (10°C) may affect light output or lamp operation – see
“Low Temp. Starting” definition.
3 Complies with European Union Restriction of Hazardous Substances Directive
(Directive EC 2002/95)
Warranty
QUICKTRONIC®Ballasts have a 5-year limited warranty. Complete warranty terms
located at www.acuitybrands.com/support/warranty/terms-and-
conditions
QUICKTRONIC North America
1-877-636-5267
techsupport@quicktronic.com
© 2022 Acuity Brands Lighting, Inc.
Specifications subject to change without notice. All trademarks referenced
are property of their respective owners. Actual performance may differ as a
result of end-user not be used unless they have been certified for electrical
safety, are compatible with the ballast and are suitable for the intended
application environment. Only replacement lamps that comply with applicable
lamp and ballast LAMP manufacturers’ ratings, compatibility listings and
instructions should be used.