TFA 31.5011.10 Dostmann Aircontrol Up Single Beam CO2 Reading Device Instruction Manual

June 8, 2024
TFA

TFA 31.5011.10 Dostmann Aircontrol Up Single Beam CO2 Reading Device

TFA-31.5011.10-Dostmann-Aircontrol-Up-Single-Beam-CO2-Reading-Device-
PRODUCT

Thank you for choosing this instrument from TFA.

Before you use this product

  • Please make sure you read the instruction manual carefully.
  • The operating instructions are enclosed with the device or can be downloaded at www.tfa-dostmann.de/en/service/downloads/instructionmanuals
  • This product should only be used as described within these instructions.
  • Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
  • Please take particular note of the safety advice!
  • Please keep this instruction manual safe for future reference.

Delivery contents

  • CO2 Monitor
  • USB-Type-C-1,5 m cable and power adaptor
  • Instruction manual

Range of application and all the benefits of your new instrument at a

glance

  • For monitoring the CO2 concentration in buildings, where people are present, eg: schools, offices, public facilities
  • Single Beam NDIR Sensor
  • Large CO2 display with extended traffic light indication (green/yellow/blue/red).
  • Display of indoor temperature (°C/°F) and humidity
  • The memory of the highest and lowest values of CO2, temperature and humidity
  • Alarm function for CO2 concentration
  • High contrast display with 4 brightness levels
  • Manual calibration function for CO2 sensor
  • Power connection via USB Type-C cable and power supply (included) or a suitable USB power source

For your safety

  • This product is exclusively intended for the range of applications described above. It should only be used as described within these instructions.
  • Unauthorized repairs, alterations or changes to the product are prohibited.

Caution!

Risk of electrocution!

  • Connect the device using the USB cable and the supplied power supply to a mains socket installed within your country’s electrical safety regulations and with a correct mains voltage (see nameplate) or connect the device via the USB cable to a suitable USB power source such as a computer, notebook.
  • The main socket must be located near the equipment and it must be easily accessible.
  • Unplug the device immediately if any fault occurs.
  • The device and the power adapter must not come into contact with water or moisture. Only suitable for indoor use.
  • Do not use the device if the housing, the USB cable or the power adaptor are damaged.
  • Operate the device out of reach of persons (including children) who cannot fully appreciate the potential risks of handling electrical equipment.
  • Connect the USB cable to the device and the power adaptor first and then plug the power adapter into the socket.
  • Route the USB cable lead so that it does not come into contact with sharp-edged or hot objects.

Important information on product safety!

  • Do not expose the device to extreme temperatures, vibrations or shocks. Avoid direct sunshine.
  • The instrument is not unbreakable. In case of falling down parts can break.

Elements

A: LCD display (Fig. 1):TFA-31.5011.10-Dostmann-Aircontrol-Up-Single-
Beam-CO2-Reading-Device-FIG-1

  • A 1: CO2 alarm limit
  • A 2: CO2 indication
  • A 3: Display of minimum values
  • A 4: CO2 value > 2000 ppm
  • A 5: Extended traffic light indication
  • A 6: Indoor temperature and humidity
  • A 7: CO2 alarm symbol
  • A 8: Display of maximum values

B: Buttons (Fig. 1+2):

  • B 1: POWER/LIGHT sensor button
  • B 2: DOWN/CALIBRATE button
  • B 3: MEM button
  • B 4: CO2 SET button
  • B 5: CO2 ALARM button
  • B 6: UP/°C/°F button
  • B 7: RESET button

C: Housing (Fig. 3):

  • C 1: USB port

Getting started

Important note:
When using the device for the first time, please make sure to connect the power supply uninterruptedly for 24 hours. The device will perform an automatic calibration within 24 hours.

  • Plug the supplied USB-C cable into the designated port on the device and connect the unit to the mains using the power adapter.

Operation

  • Press the POWER/LIGHT sensor button for 3 seconds to switch on the device.
  • The device will issue two beeps and all segments will be displayed briefly.
  • The display shows the current temperature and humidity.
  • The CO2 sensor goes into warm-up mode and starts a 150-second countdown. Afterward, the normal display appears. The device is ready for use.
  • Press the UP/°C/°F button in normal mode to change between °C (Celsius) or °F (Fahrenheit) as temperature units.
  • Briefly press the POWER/LIGHT sensor button to adjust the brightness in 4 steps (high, medium, low, off).
  • Press the POWER/LIGHT sensor button for 3 seconds to deactivate the device.

Traffic light display

  • The CO2 monitor shows the CO2 comfort level with an extended traffic light display:TFA-31.5011.10-Dostmann-Aircontrol-Up-Single-Beam-CO2-Reading-Device-FIG-3

CO2 upper limit

  • Press briefly the CO2 SET button in normal mode. Up and 2000 ppm (default) or the last adjusted upper CO2 limit appear on the display. After 3 seconds, the device automatically returns to normal mode.
  • Press and hold the CO2 SET button for 2 seconds to enter the setting mode. The value flashes.
  • Press the DOWN/CALIBRATE or UP/°C/°F button to set the desired upper limit in steps of 10ppm, while the value flashes.
  • Press and hold the DOWN/CALIBRATE or UP/°C/°F button in setting mode for fast mode.
  • Confirm the setting with the CO2 SET button.
  • The device will automatically quit the setting mode if no button is pressed for 20 seconds. The setting is saved.
  • Press the CO2 ALARM button in normal mode, to activate or deactivate the alarm function for the upper CO2 limit. appears on the display when the alarm is activated.
  • If the measured CO2 value is above the upper limit setting, an alarm sounds, and the CO2 alarm symbol flashes. Press any button to stop the alarm sound. The CO2 alarm symbol will continue flashing until the measured CO2 value is below the set alarm limit.

CO2, temperature, and humidity maximum and minimum values

  • Press the MEM button in normal mode.
  • You can now read the highest measured values for CO2, temperature, and humidity of the last 24 hours (display MAX).
  • Press the MEM button again.
  • The minimum values measured since the last 24 hours appear on the display (display MIN.
  • Press the MEM button again to return to normal mode. The device will auto-matically quit the MAX/MIN mode if no button is pressed for 3 seconds.
  • Press and hold the MEM button for 2 seconds during the highest or lowest values are displayed. The values will be deleted (display —-) and reset to the current state.

Calibration of the CO2 sensor

Automatic calibration of the CO2 sensor

  • The sensor is automatically calibrated every 24 hours to the lowest CO2 reading obtained during that period to keep the deviation low during prolonged use. To perform the calibration, the power supply must be connected continuously for 24 hours.
  • For proper functioning, it is, therefore, necessary to ensure maximum ventilation at least once a day. Otherwise, the device is using a faulty basis for automatic calibration and an incorrect display may occur. In this case, a restart under fresh air conditions or a manual calibration as described below is recommended.
  • Note: The product is not suitable for a location where ideal ventilation is not possible (in permanently closed rooms).

Manual calibration of the CO2 sensor

  • For the whole calibration process, place the device outdoors. Choose a shady and dry place. Wait 15 minutes, the device must adapt to the envi-ronment.
  • Use a pin to press the RESET button at the bottom. Wait until the normal display appears (see point 6. “Operation”).
  • Then press and hold the DOWN/CALIBRATE button for 2 seconds to enter the manual calibration mode. The CAL symbol flashes.
  • Wait approx. 20 minutes, until the normal display with a CO2 concentration of 400 ppm (fresh air) appears. The calibration is completed and the device returns to its normal state. Now you can use the device again as usual.
  • During the manual calibration operation, press the DOWN/CALIBRATE button to exit the calibration mode.

Care and maintenance

  • Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
  • Turn off the device if you do not use it. Press the POWER/LIGHT sensor button for 3 seconds.
  • Store the device in a dry place.

Troubleshooting

Problem/Solution

  • No display on the device
    • Press the POWER/LIGHT button for 3 seconds to switch on the device
    • Set the brightness with the POWER/LIGHT button
    • Connect the device with a USB cable and power adapter
    • Check the connection
  • Incorrect indication Display Err
    • Use a pin to press the RESET button
  • Indication: LL / HH
    • Outside measuring range

If your device fails to work despite these measures, contact the retailer where you purchased the product.

Waste disposal
This product and its packaging have been manufactured using high-grade materials and components which can be recycled and reused. This reduces waste and protects the environment.

Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.

Disposal of the electrical device
This product is labeled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). Please do not dispose of this product in ordinary household waste. As a consumer, you are required to take end-of- life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compa-tible disposal. Observe the current regulations in place!

Specifications

Power supply

  • USB-Type-C-1.5 m cable with power supply (included)
  • Input: 100-240V AC 50/60Hz 0.5A max
  • Output: 5.0V DC 1.0A, 5.0W
  • Average active efficiency: ≥73.62%
  • No-load power consumption: ≤0.10 W

CO2

  • Measuring method Single Beam Non-Dispersive-Infrared Technology (NDIR)
  • Measuring range 400ppm – 5000ppm
  • Resolution 1 ppm
  • Accuracy ± 100 ppm ± 10%
  • Update interval 4 seconds
  • Warm-up time 150 seconds
  • Recommended operating temperature range +10…30°C CO2 sensor (Ideal conditions also for manual calibration)

Temperature

  • Measuring range 0 °C… +50°C (32°F…122°F)
  • Resolution 0.1°C
  • Accuracy ±1 °C

Humidity

  • Measuring range 25…95%RH
  • Resolution 1% RH
  • Accuracy ±5% RH
  • Housing dimension 77 x 96 x 144 mm
  • Weight 172 g (device only)

No part of this manual may be reproduced without the written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice. The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box
www.tfa-dostmann.de.