Rondostat comfort+HR30
Electronic
Radiator controller
Scope of delivery
The radiator controller packaging contains:
- Radiator controller, without batteries
- Valve baseplate M30 x 1.5
- Display element
- Bag with adapters (Danfoss RA, RAV, RAVL)
WARNING| Danger of suffocation!
Keep packaging materials away from children.
---|---
Brief description
With the electronic radiator controller you can set your room temperature
exactly to your requirements while additionally saving energy.
Lowering the room temperature by 1 °C saves approx. 6% energy!
User-friendly
- Large adjustable display with backlight.
- Convenient programming through removal of the radiator controller from the valve.
Installation
- The radiator controller fits on the most common radiator valves M30 x 1.5.
- After being mounted, the radiator controller operates immediately with the factory setting.
Functions for increased comfort
- Individual heating program for each weekday.
- Up to 6 switching points per day and three different temperatures.
- Operating modes Holiday, Party, Day off can easily be activated.
- Parameters can be set individually, see Section 9.
Energy-saving functions
- With the window function an open window is recognised and the radiator valve closed.
- In ECO mode the room temperature is decreased by 3 °C.
- Optimised heating or lowering of the room temperature.
****CAUTION| Danger of malfunctions!
Use the radiator controller only in accordance with these operating
instructions.
Do not allow children to play with the radiator controller.
---|---
Installation
Ready to operate in three steps:
- Inserting batteries
- Setting the language, time and date
- Mounting – FInISHED
Inserting/changing batteries
The radiator controller is set for the following battery type:
- 2 Alkaline mignon cells 1.5 V, type LR6, AA, AM3 You can alternatively use the following batteries/ accumulators:
- Lithium 1.5 V, type LR6, AA, AM3
- NiMH 1.5 V, type LR6, AA, AM3
If lithium or NiMH batteries are used, Parameter 14 has to be set correctly, see Section 9.
-
Move the front part slightly upwards and remove it downwards.
The battery compartment is now accessible. -
Insert the batteries.
Ensure that the polarity is correct. -
Put the front part back on and push downward.
The software version number, then the language deutsch (German) is displayed. -
If applicable, use the adjustment dial to select a different language.
-
Confirm the selected language with the OK button. hour is displayed.
The language selection is only displayed during initial commissioning. During
future battery changes setting of time and date is prompted directly.
The battery life of new mignon cells amounts to approx. 2 years. The batteries
need changing when the symbol flashes. All the settings are retained when the
batteries are changed.
WARNING| Explosion hazard!
Non-rechargeable batteries.
Never short-circuit batteries or throw them into fire.
Dispose of used batteries ecologically.
---|---
Setting the time and date
- When hour is displayed, use the adjustment dial to set the current hour and confirm with OK . minute is displayed.
- Use the adjustment dial to set the current minute and confirm with OK . year is displayed.
- Use the adjustment dial to set the current year and confirm with OK . month is displayed.
- Use the adjustment dial to set the current month and confirm with OK . day is displayed.
- Use the adjustment dial to set the current day and confirm with OK .
The normal display with set temperature and selected operating mode is displayed.
Mounting the radiator controller
The radiator controller can be mounted easily on all common radiator valves
with a connection M30 x 1.5 without causing dirt or water staining.
WARNING| Damage to the radiator controller due to short-circuiting
through humidity and moisture!
Mount the radiator controller in dry, closed rooms only.
Protect the radiator controller against humidity, moisture, dust, direct
sunlight or high heat irradiation.
---|---
Removing the old thermostat head
- Turn the old thermostat head to the left until it stops and loosen the mounting.
- Remove the old thermostat head from the radiator valve.
Selecting the adapter
The radiator controller fits on the most common radiator valves M30 x 1.5.
Adapters are required for some valve types.
- Check whether an adapter is required and, if necessary, select the appropriate adapter.
Make| Illustration| Adapter
---|---|---
Valves M30 x 1.5 Honeywell- Braukmann.
MNG, Heimeier, Oventrop| | Not required
Danfoss RA| | Supplied
Danfoss RAV| | Supplied
Danfoss RAVL| | Supplied - Slide the adapter onto the radiator valve and turn it until you feel it click into place.
- If necessary, screw the adapter tight with a screw.
Mounting the valve baseplate
- Separate the valve baseplate from the radiator controller. To do so, slide the slide towards the .
- Turn the adjustment dial of the valve baseplate anticlockwise until it stops.
- Put the valve baseplate onto the radiator valve or the adapter and tighten by hand (without tools!).
Mounting the radiator controller
- Ensure that the slide at the radiator controller is in the open position.
- Push the radiator controller onto the valve baseplate so that the geer teeth catch and are no longer visible.
- Lock the radiator controller in the end position. To do so, slide the slide towards the .
The radiator controller carries out a self test and after 1 minute displays cycl . Subsequently the radiator controller changes to automatic mode.
The radiator controller only functions if it is interlocked in the end
position.
FINISHED! – Your radiator controller is now ready for operation with the
factory setting!
Securing controller and battery compartment
The radiator controller and battery compartment can be secured against
being removed or opened by means of a screw. These screws are not included in
the packaging.
Countersunk screws
Torx/corss recess 2.2x8mm
Type: WIN1412-KC22X8-Z or
WIN1412-KB22X8-Z
Setting the position of the display
In order to improve the legibility the display of the radiator controller can
be tilted to different positions (10°, 20°, 30°, 40°). The angle of 40° can be
fixed with the supplied display element.
- Lift the display and set it to the desired angle.
- If desired to fix the angle at 40°, slide the support bracket between the display and the main body until it clips into place.
Device overview
Operating elements and display
-
Heating/Conserve period in hours
-
Current weekday 1 … 7 (Monday … Sunday)
-
Temperature display: e.g. current room temperature or measured temperature, if configured in Parameter 9
-
Text display with 9 characters
-
Button OK : Confirm settings
-
Button PROG: Select the operating modes, set the time program;
Button pressed long (approx. 10 seconds):
Parameters can be changed; Programming: Back to next level up -
Adjustment dial: Change settings
-
Button AUTO/ECO/MANU: Change between automatic, ECO and manual mode In programming mode: Terminate (without storing)
-
Battery status
-
Operation lock
-
Symbol for Comfort temperature1 ,Comfort temperature 2 ,Conserve temperature .
Battery display
Battery status | Meaning |
---|---|
Batteries full | |
Batteries half-full | |
Batteries have to be replaced soon | |
Flashing display: Batteries are flat and have to be replaced |
Operating hints
Operating the radiator controller comfortably
The radiator controller can be removed from the radiator to facilitate
programming.
- Unlock the radiator controller. To do so, slide the slide at the radiator controller towards the .
- Pull the radiator controller off the valve baseplate.
Lost your way in the program?
Press the button AUTO/ECO/MANU automatic is displayed. The last entry is rejected.
Functionality in automatic mode
Standard time program
In automatic mode the radiator controller automatically controls the room
temperature in accordance with the stored time program.
Week program 1: at home all day
Factory preset time program is set for each day of the week (Mo – Su):
Switching point | Time | Temperature |
---|---|---|
1 | 6:00 — 22:00 | 20 °C (Comfort temperature 1) |
2 | 22:00 — 6:00 | 16 °C (Conserve temperature) |
- Two further week programs are stored in the radiator controller. Further information is available in Section 9.
- You can also adapt one of the stored week programs to your individual requirements, see Section 8.
Modifying the temperature temporarily
If you want to change the temperature specified by the time program
temporarily:
Set your desired temperature using the adjustment dial.
The change remains in effect until the next switching point.
The process of changing the temperatures permanently is described in Section
7.
Saving energy in ECo mode
In ECO mode the room temperature in automatic mode specified by the time
program is decreased by 3 °C.
To activate ECO mode press the button AUTO/ECO/ MANU until economy is
displayed.
The displayed temperature is reduced by 3 °C. ECO mode runs until you press
the button AUTO/ ECO/MANU again and select a different operating mode.
Manual mode
In manual mode the radiator controller operates at the (manually) set
temperature until you change the temperature or change to a different
operating mode.
To activate the manual mode press the button AUTO/ECO/MANU until manual is
displayed.
The temperature can be adjusted manually using the adjustment dial.
Manual mode runs until you press the button AUTO/ ECO/MANU again and
select a different operating mode.
Programming – operating modes
Overview of the operating modes
- “Party” operating mode: In this operating mode you can specify a temperature for a number of hours. After the set period has expired, the radiator controller changes to automatic mode.
- “Day off” operating mode: If a public holiday lies during the week, the automatic mode settings may not meet your requirements on these days. In such cases you can activate a “Day off” program for one or more days. After the set period has expired, the radiator controller changes to automatic mode.
- “Holiday” operating mode: In this operating mode you can specify a temperature for a specific number of days. After the set period has expired, the radiator controller changes to automatic mode.
Selecting operating modes
Selecting the “Party” or “Holiday” operating mode
-
Press the PROG button and turn the adjustment dial to the left until party or holiday is displayed.
-
Confirm the selected operating mode with the OK button.
Hours or Days flashes. -
Use the adjustment dial to set the desired number of hours or days and confirm with OK .
The temperature display flashes. -
Use the adjustment dial to set the desired temperature and confirm with OK .
The selected operating mode and the set temperature are displayed.
Selecting the “Day off” operating mode
- Press the PROG button and turn the adjustment dial to the left until day off is displayed.
- Confirm the selected operating mode with the OK button. Days flashes.
- Use the adjustment dial to set the desired number of days and confirm with OK .
The selected operating mode is displayed.
- The procedure of creating the time program for a day off is described in Section 8.
- When the number of days for holiday/day off is entered, the current day counts as the first day.
- An overview of the program structure is shown on the last page of these instructions.
Programming – temperatures
For the time program three preset temperatures which can be assigned to the switching points in the time program are possible:
- Comfort temperature 1 Factory setting 20 °C
- Comfort temperature 2 Factory setting 22 °C
- Conserve temperature Factory setting 16 °C
Setting the temperatures
-
Press the PROG button.
comfort 1 is displayed. -
Press the OK button, use the adjustment dial to set the Comfort temperature 1 and confirm with OK . saved is displayed briefly and then again comfort 1 .
-
Turn the adjustment dial clockwise until the next temperature is displayed.
-
Repeat Steps 2 and 3 for the Comfort temperature 2 and the Conserve temperature.
-
Use the AUTO button to terminate programming.
The three preset temperatures (Comfort temperature 1, 2 and Conserve temperature) can be changed at any time.
- During programming the PROG button can be used to return to the next level up.
- You can abort programming at any time by using the AUTO button.
An overview of the program structure is shown on the last page of these instructions.
Programming – time program
Planning the time program
You can specify up to 6 switching points per day.
The following has to be assigned to each switching point:
- One of the three preset temperatures (Comfort temperature 1, 2 and Conserve temperature).
- Beginning of the Heating/Conserve period
- End of the Heating/Conserve period
Example
The example shows the following time program:
Switching point | Time | Temperature |
---|---|---|
1 | 6:00 — 9:00 | 20 °C (Comfort temperature 1) |
2 | 9:00 — 12:00 | 16 °C (Conserve temperature) |
3 | 12:00 — 14:00 | 20 °C (Comfort temperature 1) |
4 | 14:00 — 17:00 | 16 °C (Conserve temperature) |
5 | 17:00 — 22:00 | 22 °C (Comfort temperature 2) |
6 | 22:00 — 6:00 | 16 °C (Conserve temperature) |
An overview of the program structure is shown on the last page of these
instructions.
Week program
You can adjust the time program to your personal weekly schedule. You have the
following options to this purpose:
- Separate time programs for weekdays (Mo – Fr) and weekend (Sa – Su)
- One time program for all days of the week (Mo – Su)
- A different time program for each day of the week (Mo, Tu, We, Th, Fr, Sa, Su)
We recommend that you record your time program before beginning programming.
Setting the time program
Selecting weekdays
- Press the PROG button. comfort 1 is displayed.
- Turn the adjustment dial clockwise until program is displayed.
- Press the OK button and use the adjustment dial to select the desired weekdays for your time program:
- Confirm the selected weekdays with the OK button.
The temperature as well as the beginning and end of the first switching point, e.g.:
- The end of a switching point is simultaneously the beginning of the next switching point.
- Only the programmed switching points are displayed.
Viewing switching points
You can use the adjustment dial to change from one setting point to another
and thus view the setting of all the programmed switching points.
Editing switching points
-
In order to edit the displayed switching point press the OK button.
The temperature display flashes. -
Use the adjustment dial to select the desired temperature (Comfort temperature 1, 2 or Conserve temperature) for the selected switching point and confirm with OK .
The beginning of the selected switching point flashes.
The time scale for programming of the switching points begins at 3:00 in the morning and ends at 2:50 on the following day. -
Use the adjustment dial to set the desired beginning for the selected switching point and confirm with OK .
The end of the selected switching point flashes. -
Use the adjustment dial to set the desired end of the selected switching point and confirm with OK . saved is displayed briefly. Subsequently the temperature as well as the beginning and end of the switching point are displayed.
-
For the further switching points also select the temperature as well as the beginning and end of the switching point as described in Steps 1 to 5.
• A switching point is not saved until the temperature, beginning and end have been confirmed with the OK button.
• If a switching point is not required, select the setting –.-.
Editing further weekdays
- When all the switching points have been edited, use the PROG button to select the weekdays.
- Edit the switching points for the next weekdays.
- After all the required weekdays have been set, terminate programming with the AUTO button. The radiator controller operates immediately in automatic mode with the set time program.
Deleting a switching point
When a switching point is not required, select the temperature setting –. and confirm with OK.
The first switching point cannot be deleted.
Adding a switching point
-
Turn the adjustment dial until add new is displayed and confirm with OK .
The temperature display flashes. -
Use the adjustment dial to select the desired temperature (Comfort temperature 1, 2 or Conserve temperature) for the new switching point and confirm with OK .
The beginning of the new switching point flashes. -
Use the adjustment dial to set the desired switching time for the new switching point and confirm with OK .
The end of the desired switching point flashes. -
Use the adjustment dial to set the desired end of the new switching point and confirm with OK .
only displayed when less than 6 switching points are programmed.
Basic settings
overview
If desired, you can modify the 16 basic settings.
Factory settings have a grey background.
Parameters marked with an * are described in more detail below.
Par. | Sett. | Meaning |
---|---|---|
Language setting |
german
English
French
Dutch
Italian
Danish
| | Preset time programs
Week program 1 “At home all day”
Week program 2 “At home ifor lunch”
Week program 3 “Working half-time”
| | Backlight display
Deactivated
activated
| | Summer/winter time changeover
No automatic changeover automatic changeover
| | Duration of the window function *
Window function not active
Valve opens at the latest after 30 minutes
…Valve opens at the latest after 90 minutes
| | Sensitivity of the window function during dropping room temperature 0.5
(sensitive) …
3.0 (less sensitive) Factory setting: 0.8
| | Sensitivity of the window function during rising room temperature 0.1
(sensitive) …
3.0 (less sensitive) Factory setting: 0.3
| | Setting the valve stroke *
Standard valve stroke
Full-stroke mode
| | Temperature representation in the display
Set/programmed temperature (setpoint temperature)
Measured room temperature
| | Upper temperature limit
The room temperature cannot be set higher than the specified upper temperature
limit
(HI LIMIT). Factory setting: 30 °C
| | Lower temperature limit
The room temperature cannot be set lower than the specified lower temperature
limit (LOW LIMIT).
Factory setting: 5 °C
| | Optimisation function
No optimisation
Optimum start
Optimum start/stop
| | Temperature offset *
To adjust the temperatures measured by the radiator controller and in the room
Factory setting: 0 °C
| | Battery type
alkaline*
Lithium NiMH (accumulator chargeable)
| | Display of the valve position
No** display of the valve position
Brief display of the valve position
| | Restore to factory setting no reset
Reset to factory setting.
Description of the parameters
Parameter 2 –
Selecting the preset time programs
-
Week program 1 (factory setting, 2 switching points):
Mo – Su at home all day This time program is described in Section 5. -
Week program 2 (6 switching points):
Mo – Fr at home in the lunch break Sa – Su like Week program 1
Switching point | Time | Temperature |
---|---|---|
1 | 6:00 — 9:00 | 20 °C (Comfort temperature 1) |
2 | 9:00 — 12:00 | 16 °C (Conserve temperature) |
3 | 12:00 — 13:00 | 20 °C (Comfort temperature 1) |
4 | 13:00 —17:00 | 16 °C (Conserve temperature) |
5 | 17:00 — 22:00 | 22 °C (Comfort temperature 2) |
6 | 22:00 — 6:00 | 16 °C (Conserve temperature) |
- Week program 3 (4 switching points):
Mo – Fr working half-time
Sa – Su like Week program 1
Switching point | Time | Temperature |
---|---|---|
1 | 6:00 to 9:00 | 20 °C (Comfort temperature 1) |
2 | 9:00 to 13:00 | 16 °C (Conserve temperature) |
3 | 13:00 to 22:00 | 22 °C (Comfort temperature 2) |
4 | 22:00 to 6:00 | 16 °C (Conserve temperature) |
Parameter 3 – Backlight
The display has a backlight in order to facilitate reading of information.
- The backlight is activated when the adjustment dial moves or a button is pressed.
- The backlight switches off if no action is carried out at the radiator controller for approx. 7 seconds in order to save energy.
Parameters 5 to 7 – Window function
In order to save energy the radiator controller closes the radiator valve when you open a window resulting in a sudden drop of the temperature.
When you close the window so that the temperature rises the radiator
controller opens the radiator valve again. If you should ever forget to close
the window, the radiator controller opens automatically after the set time in
order to ensure frost protection.
Parameter 8 – Valve stroke
The radiator controller operates with the optimum valve stroke set in the
factory.
If the entire valve stroke is to be used or if the valve does not close
completely, activate the full-stroke mode.
Parameter 9 – temperature representation in the display
- In the factory setting the set or programmed temperature (Comfort temperature 1, 2 or the Conserve temperature) is displayed.
- With the setting “measured temperature” the measured room temperature is displayed. A changeover to the set temperature is carried out by turning the adjustment dial or pressing a button.
If required, the temperature can now be reset. The display returns to the measured temperature after approx. 3 seconds.
Parameter 12 – optimisation function
Without optimisation (factory setting) the radiator controller begins to raise
or lower the room temperature at the programmed time. In order to have the
bathroom warm at 7:00, the switching point must be preponed, otherwise heating
would start only at 7:00. Possibly the switching point is preponed too much,
so that heating starts much earlier than actually needed. With optimisation
the room has already reached the desired temperature at the programmed
beginning since the radiator controller has begun to raise or lower the room
temperature at an optimal time.
-
Optimum start
The room is heated up at an optimum moment to reach the programmed temperature. -
Optimum start/stop:
The room is heated up at an optimum moment and cooled down earlier.
Parameter 13 – temperature offset Since the radiator controller measures the
room temperature in the area of the radiator, it is possible that this
temperature deviates from the temperature measured at a different point in the
room.
If, for example, 20 °C is measured in the room and at the radiator 21.5 °C,
this effect can be compensated by an offset of –1.5 °C. The display at the
radiator controller remains unchanged. Parameter 15 – Display of the valve
position When this parameter is activated (setting “1”), the calculated valve
position is displayed (0 to 100% opened) briefly.
The main display is shown again after approx. 3 minutes or when the AUTO
button is pressed.
Changing parameters
-
Keep the PROG button pressed for at least 10 seconds until Parameter 1 flashes (left-hand digit). The right-hand digit shows the current setting.
The parameter is displayed additionally in plain text.
For example, the display 1 1 stands for Parameter 1 (language) with Setting 1 (German). -
If desired, use the adjustment dial to select a different parameter (left-hand digit).
-
Press the OK button to edit the parameter. The current setting of the parameter flashes (right hand digit).
-
Use the adjustment dial to set the desired setting (right-hand digit) and confirm with OK .
-
The parameter being edited flashes (left-hand digit).
-
For the further parameters repeat Steps 2 to 4.
-
Use the AUTO button to return to automatic mode.
Further functions
Monitoring functions
Window function
If you open a window causing the temperature to drop, the radiator controller
closes the radiator valve in order to save energy. window is displayed.
When the temperature rises again, but at the latest after the set period
(factory setting: 30 minutes), the radiator controller opens the radiator
valve again. You can also open the radiator valve beforehand by pressing the
AUTO button or turning the adjustment dial.
The sensitivity of the radiator controller to a temperature drop or
temperature rise can be set, see Section 9, Parameters 5 to 7.
Valve protection
If the radiator valve has not been opened completely for 2 weeks, a self test
is carried out. The radiator controller opens the radiator valve briefly on
the subsequent.
Monday in order to prevent seizing. cycl is displayed. Frost protection If the
temperature drops below 5 °C, the radiator controller opens the radiator valve
until the temperature rises above 6 °C again. This prevents the heating from
freezing up. frost is displayed.
The heating may not be switched off. Otherwise the radiator controller cannot
carry out the frost protection function.
Summer break
If you have switched off the central heating system in summer and do not want
to waste the batteries of the radiator controller, you can close the radiator
valve continuously.
Closing the valve
- Press the button AUTO/ECO/MANU until manualis displayed.
- Turn the adjustment dial anti-clockwise until off isdisplayed.
The radiator valve now remains closed. The valve and frost protection function remains active.
Opening the valve
Use the AUTO/ECO/MANU button to change to automatic mode.
– or – Set the desired temperature in manual operation.
Child-proofing / operation lock
You can block the radiator controller to protect it against unauthorised
operation:
Keep the AUTO/ECO/MANU and PROG buttons pressed simultaneously for at least 3
seconds.
The symbol is displayed.
The same key combination is used to release the radiator controller again for
operation.
Help with problems
Error table
Problem/ Display | Cause | Remedy |
---|---|---|
flashes | Batteries flat | Replace the batteries. |
Device defective | Replace the device. | |
Motor cannot be moved. | Check the |
installation. If appropriate, remove the dirt.
The radiator does not become cold.| The radiator valve does not close fully.|
Check the
installation. If appropriate, change to full-stroke mode (Parameter 8).
The room does not heat up during optimisation| Heating is not switched on in
time| Ensure that the heating system is switched on.
Motor does not move| Valve baseplate not interlocked| Set the slide to the
position .
Emergency operation when batteries are flat
- Unlock the radiator controller. To do so, slide the slide at the radiator controller towards the .
- Pull the radiator controller off the valve baseplate.
- Operate the radiator valve by hand using the adjustment dial on the valve baseplate.
Restoring the factory setting
- Keep the PROG button pressed for approximately 10 seconds until Parameter 1 flashes (left-hand digit).
- Use the adjustment dial to select Parameter 16 (lefthand digit) and Setting 1 (right-hand digit).
- Press the OK button to restore the factory setting.
Technical data
Type | HR30 |
---|---|
Protection class | IP30 |
Supply voltage | Batteries 2 x 1.5 V; type LR6, AA, AM3 |
Connection to the radiator | M30 x 1.5 |
Ambient temperature | 0 … 50 °C |
Dimensions | 94 x 50 x 69 mm |
Ambient conditions | For living area, business and trade sections as well as |
small businesses
Humidity| 10 … 90% rel. humidity
Disposal
The radiator controller has to be disposed of in accordance with WEEE directive 2002/96/EC – Waste Electrical and Electronic Equipment directive.
| Dispose of the packaging and product in a corresponding recycling centre.
Do not dispose of the unit with the domestic refuse.
Do not burn the product.
---|---
Programming – overview
Temperatures and operating modes
Time program
Novar GmbH
a Honeywell Company Gartenstraße 49
58511 Lüdenscheid
www.homexpertbyhoneywell.com
Subject to change in order to improve the product.
Hotline: xxx xxx xxx
**Strandvejen 42 • Saksild • 8300 Odder
86 62 63 64 •www.automatikcentret.dk
info@automatikcentret.dk**
Documents / Resources
|
Honeywell HR30 Electronic Radiator
Controller
[pdf] User Manual
HR30, Electronic Radiator Controller, Radiator Controller, Electronic
Controller, Controller, HR30 Controller
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>