NAUXUS NX-HOOD 30 Ultra Quiet Powerful Vent Hood Installation Guide
- June 9, 2024
- Nauxus
Table of Contents
Installation Guide and Users Manual
Built-In Series (Insert Liner)
NX-HOOD 30 NX-HOOD 36
Important Safety Notice
Read all Instructions before Installing and operating this appliance
- The installation i n this manual is intended for qualified installers, service technicians or persons with similar qualified background. Installation and electrical wiring must be done by qualified profession- als and in accordance with all applicable codes and standards, including fire-rated construction.
- DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background.
- Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any parts for installing, cleaning or servicing.
- Activating any switch ON before completing installation may cause ignition or a n explosion.
- Due to the size and weight of this range hood, two people installation 1s recommended.
To reduce the risk offire , electric shock, or injury to persons:
- For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and va-pors.
- The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre-vent power from being switched ON accidentally.
- Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics or garages.
- Ducted fans MUST always be vented to the outdoors.
- Use only metal ductwork and this unit MUST be grounded.
- Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent back drafting.
- When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid-den utilities.
- All electrical wiring must be properly installed, insulated and grounded.
- Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire.
- Check all joints on duct work to insure proper connection and all joints should be properly taped.
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the vendor.
To reduce the risk of a stove top grease fire:
- Keep all fan, baffle, spaces, filter, grease tunnel, oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle, spaces, filter, grease tunnel and oil container.
- Always turn range hood ON when cooking at high heat or when cooking flaming foods.
- Use high settings on cooking range only when necessary.
- Never leave surface units unattended at high settings. Boil oven cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
- Clean ventilating fan frequently.
- Always use appropriate cookware and utensils size.
- Always use cookware appropriate for the size of the surface element.
To reduce the risk of injury t o persons in the event of a stove top grease fire:
-
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn OFF the burner.
BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned.
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames DO NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately. -
DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.
-
Use an extinguisher ONLY if:
-
You know you have a Class A , B, C extinguisher, and you already know how to operate it.
-
The fire is small and contained in the area where it is started.
-
The fire department is being called.
-
You can fight the fire with your back to an exit.
To reduce the risk of injury to persons in the event of a gas leaks:
- Extinguish any open flame.
- DO NOT turn on the range hood fan or any type of ventilator.
- DO NOT turn on the lights or any type of appliance.
- Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and fire department, or dial your local emergency service immediately.
Your safety and the safety of others is very important. We have provided many important safety mes-sages in this manual and on your appliance. Always read and obey all safety messages. All safety mes- sages will tell you what the potential hazard 1s, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING
This is the safety alert symbol. This symbol alerts you to potential hazards
that can hurt you and others.
All safety messages will follow the safety a lert symbol and the word
“WARNING”.
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to ob- serve the instructions given here for inst allation , maintenance and suitable use of the product. The manufacturer and/or distributor/reseller further declines all responsibility for injury due to neg- ligence and the warranty of the unit automatically expires due to improper maintenance. The manufacturer and/or distributor/reseller will not b e held responsible for any damages to personal property or real estate o r any bodily injurie s whether caused directly or indirectly by the range hood.
Tools needed:
Parts Supplied:
Venting Requirements
- Vent system must terminate to the outside (roof or side wall).
- Do not terminate the vent system in an attic or other enclosed area.
- Do not use 4″ (10.2 cm) laundry-type wall caps.
- Use metal/aluminum vent only. Rigid metal/ aluminum vent is recommended.
- Do not use plastic vent.
- Always keep the duct clean to ensure proper airflow.
- Calculate the following figures before instal-lation:
1. Distance from the floor to the ceiling.
2. Distance between the floor to the coun-tertop/stove (US Standard. 36′).
3. Distance between the countertop/stove to the range hood (recommend* 24″ to 30′).
4. Height of hood and duct cover.
For the most efficient and quiet opera-tion:
- it is recommended that the range hood be vented vertically through the roof through 6″ (15 cm) round metal/ aluminum vent work.
- The size of the vent should be uniform.
- Use no more than three 90° elbows.
- Make sure there is a minimum of 24″ (61 cm) of straight vent between the elbows if more than one elbow is used.
- Do Not install two elbows together.
- The length of vent system and number of elbows should be kept to a minimum to pro-vide efficient performance.
- The vent system must have a damper. If roof or wall cap has a damper, Do Not use damp-er supplied with the range hood.
- Use duct tape to seal all joints in the vent system.
- Use caulking to seal exterior wall or roof opening around the cap.
Height & Clearance
Height & Clearance (continued)
IMPORTANT:
-
A minimum of 6″ round (standard for this range hood) must be used to maintain maximum airflow efficien-qt.
-
Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided duct.
-
Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions and caps.
-
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6″ to 7 or 8″. If a reducer is used, install a long reducer instead of a pancake reducer. Reduc-ing duct size will restrict airflow and decrease airflow, thus reduce duct size as far away from opening as possible.
-
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.
-
Minimum mount height between range top to hood bottom should be no less than 24″.
-
Maximum mount height should be no higher than 31″
-
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency.
-
If available, also refer to manufacturer’s height clearance requirements and recommended hood mounting height above range.
Minimum Duct Size: -
Round- 6″ minimum
Calculating vent system length
To calculate the length of the system you need, deduct the equivalent feet for
each vent piece used in the system from the recommended maximum duct run.
Duct Run Calculation:
Recommended maximum run
6″ or 3-1/4 x 10″ duct| I 50 ft
Vent piece deduction
Each 90° elbow used| 9 ft
Each 45° elbow used| 5 ft
Each 6″ to 3/14 x 10″ transition used| 7 ft
Side wall cap with damper| 0 ft
Roof cap| 0 ft
Duct Run Calcination example:
One roof cap, two 90° elbow, and one 45° elbow used: tiy1 + 9ft + 9fi + 5fi =
used Deduct 2afrom 50ft, 27fi maximum available for straight duct run.
Venting Methodsil
- This power pack range hood insert is factory set for venting through the roof or wall.
- Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
I MPORTANT:
- NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces. ceiling, attics or garages. All exhaust must be ducted to the outside.
- Usc metal/aluminum duct work only.
- Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
- Use caulking to seal exterior wall or roof opening around the cap.
Charcoal Filter Installlatrola)uctless)
NOTE:
- Remove grease filters from the hood.
- Position the charcoal filters onto the side of the motor, aligning the mounting points, turn until it locks. Re-install grease filters.
- Charcoal filters must be replaced after 120 hours of use (or approximately every 3 months based on the average of I to 2 hours of daily cooking time). Available at your local resellers.
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances. (Please consult with a qualified electrician for 220-Volt 50 Hz voltage) It is the customer’s responsibility: To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/ NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Pan I and C22. 2 No. 0-M91 – latest edition and all local codes and ordinances.
- If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
- A 120-volt, 60 Hz, AC-only, fused electrical supply is required on a separate I5-amp circuit, fused on both sides of the line.
- Do not ground to a gas pipe.
- Do not have a fuse in the neutral or ground circuit.
- RISK OF ELECTRICAL SHOCK. This range hood must be properly grounded. Check with a qualified electrician if you are not sure whether the range hood is properly grounded.
- The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexi-ble armored or non-metallic sheathed copper cable A U L – or C.S.A. – listed strain relief must be provided at each end of the power supply cable. Do not use extension cord or adapter plug with this appliance.
- The range hood must be connected with copper wire/plug only.
- Always use plug provided. If not possible, connect three wires according to its color (black to hot, white to neutral, and green to ground) to house wires and cap with wire connectors:
Wire sizes (copper wire only) and connections must conform with the rating of the appliance as speci-fied on the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition, or CSA Standards C22. 1-94, Canadian Electri-cal Code Pan I and C22. 2 No. 0-M91 – latest edition• and all local codes and ordinances. A U.L. – or C.S.A. – listed conduit connector must be provided at each end of the power supply cable (at the range hood and at the junction box). Copies or the standards hued may be obtained holm National Fire Proration Madanten CSA Iriterruhowd Raneremarch Part 8501 Pam Plaierni Milky Road Quincy, Sleasachinerts 02269 Clevelard. Ohm 441’1.5575
WARNING
Severe Injury
Hood may have very shape edges. Please wear protective gloves if it is
necessary to remove any parts for installing, cleaning or servicing.
WARNING
Severe Injury
Hazard of electrical shock! Electrical wiring must be done by qualified person
Installation
WARNING
Excessive Weight
Require two or more person to move and install this range hood. Spinal or
other bodi-ly injuries could occur if it is not followed.
INSTALL THE HOOD
Due to excessive weight two or more person is recommended for this step.
NOTE: DO NOT INSTALL THIS POWER PACK RANGE HOOD INSERT BEFORE RUNNING A
TEST AND MAKE SURE THE UNIT IS IN GOOD CONDITION MECHANICAL DAMAGE MIGHT HAVE
OCCURRED DURING TRANSPORTATION.
- We Pre-screw the 6 screws on the housing, please remove 6pcs screws from the unit, then use it to attach the rubber plate and 6″ round exhaust vent adapter to the opening.(ref. to Fig A).
- Remove the decorative panel from the power pack range hood.
- Cut an openning in the bottom of the cabinet, using the dimensions shown in the table below (ref. to Fig. B ).
- Insert the range hood in the cabinet and secure with the (4) mounting screws from the inner side of the range hood (Fig. C). Note: Wood blocking might need to be built if it’s not available in order to secure the mounting screws.
- Connect the duct and power cord. Replace the decorative panel.
Model | X | Y |
---|---|---|
NX-Hood 30 | 26 1/2” | 10 3/4” |
NX-Hood 36 | 34 1/2” | 10 3/4” |
Range Hood Operations
Turn On:
- Press the speed control (Low Speed, Medium Speed, High Speed) switch to select the desired level of power. Once button is pressed, the previous speed mode will cancel.
- Press the Light Switch to power on the lights.
Turn Off:
- Press the Power Switch to turn off the power.
- Press the Light Switch to power off the lights
Product List
No. | Parts | Qty |
---|---|---|
1 | Stainless Steel Body | 1 |
2 | Rubber Gasket of Duct Connector | 1 |
3 | Duct Connector | 1 |
4
I| LED 3W 12V Light| 2
5| Control Panel Switch| 1
6| Motor| 1
No.| Parts| Qty
---|---|---
7| Filters| 2/3(vaiy with size)
8| Connector box| 1
9| 12V-7W Trandformer| 1
10| Power Cord| 1
11| 1 2uf Capacitor| 1
Product Dimension
Wiring Diagram
Troubleshooting
WARNING
Hazard of electrical shock!
Do not perform service on an electrically live system. Disconnect the main
electrical supply before servicing this device. Touching electrical connectors
or other exposed elec-trical circuitry inside this range hood when they are
energized could result in death, serious bodily injury, or property damage.
- If the range hood does not operate after installa-tion:
- The range hood vibrates when the blower is on:
- The blowers seems weak:
- The lights work but the blower is not spinning at all, is stuck or is rattling.
- The hood is not venting out properly:
• Check if the range hood has been plugged in, make sure that all power has
been turned back on and all electrical wiring are properly connected.
• Swap out light assembly to working ones to deter-mine whether it is caused
by defective bulbs. (See Replacing the light bulbs, page 14)
• The range hood might not have been secured prop-erly.
• Check that the duct sized used is at least 6″ or 3-1/4 x 10″. Range hood
WILL NOT function efficiently with insufficient duct size. For example: 7″
duct over 6″ hole and loosely secured.
• Check if duct is clogged or if damper unit is not opening properly. A tight
mesh on a side wall cap unit might also cause restriction to the air flow.
• The blower might be jammed or scraping the bot-tom due to shipping damage.
• Make sure the distance between the cook top and the bottom of the hood is
within 28″ and 31″ in range.
• Reduce the number of elbows and length of duct work. Check if all joints are
properly connected, sealed, and taped.
• Make sure the power is on high speed for heavy cooking
NOTE: For all other inquiries , please contact us. Our contact information can be found on the back cover page.
Use and Care Information
WARNING — TO REDUCE THE RISK OF FIRE, ELEC-TRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner in-tended by
the manufacturer. If you have questions, contact the manufacturer. Before
servicing or cleaning unit, switch power off at service panel and lock switch
power off at service panel and lock service panel to prevent power from being
switched on accidentally. When the service discon-necting means cannot
blocked, securely fasten prominent warning device such as a tag to the service
panel.
CAUTION: For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
WARNING — TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave
surface units unattended at high settings. Boil overs cause smoking and greasy
spill-oven that may ignite. Heat oils slowly on low or medium settings. Always
turn hood ON when cooking at high heat or when cooking flaming foods. Clean
ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or filter. Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING — TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES with a close-fitting
lid, cookie sheet, or metal tray, then turn off the burner. BECAREFUL TO
PREVENT BURNS. If the flames do not go out immediately, EVACU-ATE AND CALL THE
FIRE DEPARTMENT. NEVER PICK UP A FLAMING PAN— you may be burned. DO NOT USE
WATER, including wet dishcloths or towels — a violent steam explosion will
result. Use an extinguish-er ONLY if: You know you have a Class ABC
extinguisher, and you already know how to operate it. The fire is small and
contained in the area where it is started. The fire department is being
called. You can fight the fire with your back to an exit.
Specifications
Specifications-:
Body| Stainless Steel / Sheet Metal
Power Rating| 120V/60Hz (USA & Canada standard)
General Input Power| 120W + # of Light x Votage of Light
Motor Input Power| 120 W
Motor Revolution| 600 RPM (±10%) to 1300 RPM (±10%)
Levels Of Speed Control| 3 Levels
Maximum Airflow| 560 CFM
Air Pressure| 150 Pa (200 Pa Maximum)
Noise Level (dB) )| Approximately 35 to 62 (Lowest to highest Speed)
Motor Type| Single Chamber Ultra Quiet
Fan Type| Centrifugal / Sirocco
Control Type| 3 Spd Mechinical Push Button
Filtration Type| Baffle Filter
Illumination| LED 3W 12V
Venting Size| Top, 6 inches Round
Interference Protection| Radio Frequency Interference Protected
- Subject to change without notice, please contact your local reseller for details.
Maintenance
SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating! For optimal operation, clean range hood and all baffle/spacer/filter/grease tunnel/oil container regularly. Regular care will help preserve the appearance of the range hood. Cleaning Exterior surfaces:
-
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g. Comet Power Scnlvx. EZ-Offs oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel surface. For heavier soil use liquid degrease such as “Forumla 409®” or “Fantastic®” brand cleaner.
-
If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner.
CAUTION: Do not leave on too long as this may cause damage to hood finish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood. -
After cleaning, you may use non abrasive stainless steel polish such as 3M® or ZEP6, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
-
DO NOT allow deposits to accumulate or remain on the hood.
-
DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.
-
DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after ex-posure and wipe dry with a clean cloth. Cleaning Filters (Baffle or Aluminum Grease): IMPORTANT: Drain oil from oil containers before oil and residue overflow!
-
The metal filters fitted by the factory are intended to filter out residue and grease from cooking. It need not be replaced on a regular basis but are required to be kept clean.
-
Filters should be cleaned after every 30 hours of use.
-
Remove and clean by hand or dishwasher. Spray “Formula 4096” or equivalent degreasing detergent and leave to soak if heavily soiled. Dry filters and re-install before using hood. Replacing Filters:
-
Should aluminum grease filters wear out due to age and prolonged use, please contact your local reseller for replace-ment filters. (Note: Also replace damaged filter that has punctured or broken mesh, bent or broken frame.) Replacing the light bulb:
-
This range hood uses LED bulb (please refer to the actual specification of the hood purchased): LED 3W 12V
Maintenance (continued)
Replacing LED Light Fixture:
- This range hood uses LED light fixture: 3W 12V LED
- Make sure the range hood is unplugged or turn OFF breaker and the lights are cool to touch.
- Place a flat-head screwdriver between light housing and hood body, gently pry up the light housing and search for the metal clip.
- Apply force to the metal clip and pull out the light fixture. Disconnect the power cable and discard the old light fix-ture.
- Reverse the steps to install a new halogen light fixture. Turn ON breaker and range hood to test for operation.
TO OBTAIN SERVICE UNDER WARR. I VT1:
Warranty
YOU IntISI present proof.ot on nai purchase dare
Please provide an original dated proof of purchase (sales receipt / invoice)
in order to obtain service under warranty.
One Year Parts Warranty: For one year from the date of original purchase, your
local reseller will provide free of charge, non-consumable replace-ment parts
or components that failed due to manufacturing defects. Subject to the
conditions and limitations set forth below, your local reseller will, at its
option, either repair or replace any part of its products that prove defective
by reason of improper workmanship or materials. Repaired parts or replacement
products will be provided by your local reseller on an exchange basis, and
will be either new or refurbished to be functionally equivalent to new. The
consumer is re-sponsible for all shipping costs. Consumable parts not covered
by this warranty include but not limited to: Light bulbs, metal, aluminum and
charcoal filters.
Who is Covered: This warranty is extended to the original purchaser for
products purchased for ordinary homc use. This Warranty Will Be Voided When:
Product damaged through negligence, improper installation, accident, abuse,
misuse, natural disaster, insufficient or excessive electrical supply,
abnonnal mechanical or environmental conditions, or any unauthorized
disassembly, repair, modification, or failure to follow installation
instructions. When product is used commercially or other than its intended
purpose. Damaged because of improper connection with equipment of other
manufacturers. Repaired or modified by anyone other than your local reseller’s
authorized agents. This limited warranty also does not apply to any product on
which the original identification information has been altered, obliterated or
removed, has not been handled or packaged correctly or has been sold as
second-hand. What is Not Covered: Consumable parts such as light bulbs, metal
and charcoal filters. The natural wear of finish, and wear due to improper
maintenance, use of corrosive and abrasive cleaning products. pads, and oven
cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage,
or improper installation. Damage of product caused by accident, fire, floods
or act of God. The manufacturer and/or distributor/reseller is not liable for,
and does not cover under warranty, any loss of properties or any costs
associated with removing, servicing, installing, or determining the source of
problems with this product. This warranty is valid in the country of the
original purchase at retail. It is non-transferable and applies only to the
original purchaser and does not extend to subsequent owners of this product.
Any applicable implied warranties, including the war-ranty of merchantability,
are limited in duration to a period of express warranty as provided herein
beginning with the date of original purchase at retail and, no warranties,
whether express or implied, shall apply to this product thereafter. To obtain
warranty service, you may contact your local reseller from which you purchased
this product. Please confirm the terms of your local reseller’s policies prior
to contacting. Typically, you must include product identification information,
including model number and serial number with a detailed description of the
problem you are experiencing. You must also include proof of the date of
original retail purchase as evidence that the product is within the applicable
warranty period.
Disclaimer
Carefully inspect all items for damages before accepting delivery. note any
damages on the freight bill or express receipt. request name and signature of
the carrier’s agent and keep copy to support your claim. Upon acceptance of
items, owner assumes responsibility for its safe arrival. Report damages to
the carrier and file a claim immediately. Failure to do so may result in the
denial of your claim. The carrier will furnish you with necessary forms for
filing a claim.
Damages caused during transit are not covered under our warranty. Please
contact us to file an insurance claim.
Please inspect contents of package(s) carefully upon receiving! We must be
notified of any damages and/or missing parts within five (5) days upon your
receipt of package(s). Claims will not be accepted after five (5) days.
NOTE: Items were thoroughly tested and carefully packed in our factory
before shipping.
Products must be returned in good working condition with ALL original parts
and documentation packed in ALL original cartons, fillers and shipping
cartons. A restocking fee of 15% will be charged for all approved return(s).
Exchanges or returns may not be accepted if any packaging is missing.
Make sure to inspect the hood for damages and defects before installation.
Appearance flaws of the hood found after installation and not affecting hood
performance is not covered under our warranty for returns or exchang-es.
Service visits not covered under warranty will carry a service charge.
Before Installation: Return for exchange or refund (please see above for
acceptable returns). After Installation: NO exchange or refund.
Contact Us
If you need any assistance, please contact with us
service@nauxus.com or call us (832)941-6306.
Please have your order number and model of the range hood ready. This
information will help them better respond to your request. If you need
replacement parts, we recommend that you only use genuine parts. Our
accessories and pans are engineered and designed specifically for this series
of range hood, each is rigorously tested assuring the utmost in durability and
reliability, providing a factory match, factory-installed appearance and
functionality tailored to each individual range hood model.
The information in this document i s subject to change without notice, please contact your local reseller for updated details.
Questions, problems, missing parts? Before returning to the store ,
call NAUXUS Customer Service
8 a.m.-6 p.m.,EST, Monday-Frida
1-(832)941-6306 1-(909)858-6868
NAUXUS.COM
Documents / Resources
|
NAUXUS NX-HOOD 30 Ultra Quiet Powerful Vent
Hood
[pdf] Installation Guide
NX-HOOD 30, NX-HOOD 36, Ultra Quiet Powerful Vent Hood, Powerful Vent Hood, 30
Ultra Quiet Vent Hood, Vent Hood, Hood
---|---
Read User Manual Online (PDF format)