robustel R1511 4G LTE Dual Ethernet Router User Manual

June 9, 2024
robustel

Robustel R1511 Hardware Manual
R1511
Hardware Manualrobustel R1511 4G LTE Dual Ethernet
Router

Version: 1.0.0
Date: July 6, 2022
RT061_HM_R1511

R1511 4G LTE Dual Ethernet Router

Robustel R1511 Hardware Manual
Regulatory and Type Approval Information
Table 1: Directives

2011/65/EU| The European RoHS2.0 2011/65/EU Directive was issued by the European parliament and the European Council on 1 July 2011 on the restriction of the use of certain Hazardous substances in electrical and electronic equipment.
---|---
On June 4, 2015, the Official Journal of the European Union published the RoHS2.0 Amendment Directive (EU)

In 2015/863, four phthalates (DEHP, BBP, DBP, DIBP) were officially included in the list of restricted substances in Appendix II of RoHS 2.0 (2011/65/EU).

From July 22, 2019, all electronic and electrical products exported to Europe (except medical and monitoring equipment) must meet this restriction; from July 22, 2021, medical equipment and

monitoring equipment will also be included in the scope of control.

2012/19/EU| The European WEEE 2012/19/EU Directive was issued by the European parliament and the European Council on 24 July 2012 on waste electrical and electronic equipment.
2013/56/EU| The European 2013/56/EU Directive is a battery Directive which published in the EU official gazette on 10 December 2013. The button battery used in this product conforms to the standard of 2013/56/EU directive.

Table 2: Toxic or Hazardous Substances or Elements with Defined Concentration Limits

Name of the Part Hazardous Substances
(Pb) (Hg)
Metal parts o
Circuit modules o
Cables and cable assemblie o
Plastic and polymeric parts o

o: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in RoHS2.0.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part might exceed the limit requirement in RoHS2.0.
-: Indicates that it does not contain the toxic or hazardous substance.
Radio Specifications

RF technologies 2G, 3G, 4G, Wi-Fi


Cellular Frequency*

| 2G: GSM: B3/B8
3G: WCDMA: B1/B8
4G: LTE FDD: B1/B3/B7/B8/B20/B28A LTE TDD: B38/B40/B41
Max RF power| 33dBm±2dB@GSM, 24dBm+1/-3dB@WCDMA, 23±2dBdBm@LTE

* May vary on difference models.
Simplified EU Declaration of Conformity
We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou, China, declare that this radio equipment complies with all applicable EU directives. The full text of the EU DoC is available at the following internet address: www.robustel.com/certifications/

FCC Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
IC Declaration of Conformity
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
(1)This device may not cause interference.
(2)This device must accept any interference, including interference that may cause undesired operation of the device.
Radio Frequency Exposure Statement for IC
This device complies with IC exposure limits set forth for an uncontrolled environment. This device shall be installed and operated with minimum distance 20cm between the radiator & body.
Related download link
Find more product documents or tools at: www.robustel.com/en/documentations/
Technical Support
Tel: +86-20-82321505
Email: [email protected]
Web: www.robustel.com
Document History
Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.

Date| Firmware Version| Document Version| Change Description
---|---|---|---
6-Jul-22| 5.0.0| 1.0.0| Initial release.

Overview

Robustel R1511 industrial-grade cellular VPN wireless router supports GSM 2G network, WCDMA 3G network, LTE 4G network to provide high-speed wireless network bandwidth for devices through wireless connection.

Package Checklist

Before commencing installation ensure your package has the following components:robustel R1511 4G LTE Dual Ethernet Router -
FIG Note: the accessories could be different on specific order.
Panel Layout(May vary on difference models)robustel R1511 4G LTE Dual
Ethernet Router - FIG 2

Interface Descriptions

  1. PIN Description
PIN Description Note
1 V+ Power Supply Positive

Note: 1)      The input voltage is 9 to 36V DC (Without ignition sensing)

2| V-| Power Supply Negative
3| RXD/B| RS232 Data Receive/RS485_B, may vary on different model.|
4| GND| Signal Ground
5| TXD/A| RS232 Data Transmission/RS485_A, may vary on different model.

2. LED Indicator.

Name Color Status Description
RUN Green On, solid Router is powered on (System is initializing)
On, blinking Router starts operating
Off Router is powered off
MDM Green On, solid Link connection is working
On, blinking Data is sent and received.
Off Link connection is not working
USR USR-OpenVPN Green On, solid
Off OpenVPN connection is not established
USR-IPsec Green On, solid IPsec connection is established
Off IPsec connection is not established
RSSI Green On, solid Signal Level: Best Signal Level

Wireless module: 21-31dB (signal strength)

Green| On, slow blinking (1s)| Signal Level: Average Signal Level

Wireless module: 11-20dB (signal moderate)

On, fast blinking| Signal Level: Abnormal Signal Level

Wireless module: 21-31dB (signal weak)

Green| Off| No signal
WLAN| Green| On, solid| Wi-Fi is enabled and working properly
Green| Off| Wi-Fi is disabled or not working properly

Note: You can choose the display type of USR LED. For more details, please refer to
RT123_SM_RobustOS Software Manual, Services > Advanced > System >System Settings > User LED Type.
3. Reset Button.

Function Operation
Reboot Press and hold the RST button for 2~ 5 seconds under the operating

status.
Restore to default configuration| Press and hold the RST button  for 5~10 seconds, the RUN LED  starts blinking quickly, the router will restore to default configuration.
Restore to factory default settings| Once the operation of restoring default configuration is performed twice within one minute, the router will restore to factory default settings.
Note: The more details please refer to RT123_SM_RobustOS Software Manual, 2.3 Factory Reset.

4. Ethernet Ports. There are two Ethernet ports on R1511, including ETH0 (WAN/LAN), and ETH1. Each has two LED indicators. The green one is a link indicator but the yellow one doesn’t mean anything (always off). For details about status, see the table below.

Ethernet LED Indicator Status Description
Link indicator (Green) On, solid Connection is established
On, blinking Data is being transferred
Off Connection is not established

Hardware Installation

  1. SIM Card Installation. Insert the SIM cards into the device, then stick the sticker.robustel R1511 4G LTE Dual Ethernet Router - FIG5

  2. Antenna Installation. Rotate the antenna into the antenna connector accordingly.

  3. Terminal Block Installation. Insert the 2PIN, 3PIN terminal blocks into the interfaces connector.

  4. Mounting Kit installation.
    1 Wall mounting 2 DIN rail mountingrobustel R1511 4G LTE Dual Ethernet
Router - FIG9

  5. Connect the Router to a Computer
    Connect a standard Ethernet cable to the port marked ETH0~ETH1 at the front of the R1511 Router, and connect the other end of the cable to your computer.robustel R1511 4G LTE Dual Ethernet Router -
FIG10

  6. Power Supply installation. There are two cables associated with the power adapter. Following to the color of the head, connect the cable marked red to the positive pole through a terminal block, and connect the yellow one to the negative in the same way.
    Note: The range of power voltage is 9 to 36V DC.robustel R1511 4G LTE
Dual Ethernet Router - FIG11

Login to the Device

  1. Connect the router’s Ethernet port to a PC with a standard Ethernet cable.
  2. Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure “Use the following IP address”.
  3. To enter the gateway’s web interface, type http://192.168.0.1 into the URL field of your Internet browser.
  4. Use login information shown in the product label when prompted for authentication.
  5. After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device.
  6. The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface->Link Manager->Link Setting->WWAN Settings to finish the specific setting.
  7. The more configuration details please refer to RT123_SM_RobustOS Software Manual. (END)

Support: [email protected]
Website: www.robustel.com
©2022 Guangzhou Robustel Co., Ltd.
All rights reserved. Subject to change without notice.
RT061_HM_R1511

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

robustel User Manuals

Related Manuals