Remote Controller Specifications

Model| RS-S9KI,RU-S9KI
RS-S12KI,RU-S12KI
RS-S18KI,RU-S18KI
---|---
Rated Voltage| 3.0V( Dry batteries R03/LR03×2)
Signal Receiving Range| 8m
Environment| -5°C~60°C(23°F~140°F)

Quick Start Guide

NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.

SPECIAL NOTE

  • Button designs on your unit may differ slightly from the example shown.
    If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.

  • When there are wide differentces between “Remote controller Manual” and “OPERATION & INSTALLATION MANUAL” on function description, the description of “OPERATION & INSTALLATION MANUAL” shall prevail.

Handling the Remote Controller

Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use.

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

BATTERY NOTES
For optimum product performance:

  • Do not mix old and new batteries, or batteries of different types.
  • Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.

BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.

TIPS FOR USING REMOTE CONTROL

  • The remote control must be used within 8 meters of the unit.
  • The unit will beep when remote signal is received.
  • Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
  • Remove batteries if the remote will not be used more than 2 months.

CAUTIONS FOR USING REMOTE CONTROL
The device could comply with the local national regulations.

  • In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
  • In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
    (1) This device may not cause harmful interference, and
    (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.

Model: RS-S9KI,RU-S9KI
RS-S12KI,RU-S12KI
RS-S18KI,RU-S18KI

Remote Screen Indicators

Information are displayed when the remote controller is power up.

Mode display

AUTO|
---|---
COOL|
DRY|
HEAT|
FAN|
| Displayed when data transmitted.
---|---
| Displayed when remote controller is ON.
| Displayed when TIMER ON time is set
| Displayed when TIMER OFF time is set
| Shows set temperature or room temperature, or time under TIMER setting
| Displayed when ECO feature is activated
| Indicated all the current settings are locked
| Displayed when Follow Me feature is activated(some units)
| Displayed when SLEEP feature is activated
| Displayed when FRESH feature is activated(some units)
| Displayed when TRUBO feature is activated
| Horizontal louver auto swing display
| Vertical louver auto swing display(some units)

Fan speed indication

HIGH High speed
MED Medium speed
LOW Low speed
NO display Auto fan speed

Note:
All indicators shown in the figure are for the purpose of clear presentation. But during the actaul operation, only the relative function signs are shown on the display window.

How to Use Basic Functions

Basic operation
ATTENTION! Before operation, please ensure the unit is plugged in and power is available.

COOL Mode

  1. Press the MODE button to select COOL mode.
  2. Set your desired temperature using the TEMP ▲ or TEMP ▼ button.
  3. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
  4. Press the ON/OFF button to start the unit. .

SETTING TEMPERATURE
The operating temperature range for units is 16-30°C (60-86°F)/20-28 C(68-82 F). You can increase or decrease the set temperature in 1°C (1°F) increments.

AUTO Mode
In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT(not applicable for cooling only model) operation based on the set
temperature.

  1. Press the MODE button to select AUTO.
  2. Set your desired temperature using the TEMP ▲ or TEMP ▼ button.
  3. Press the ON/OFF button to start the unit.

NOTE: FAN SPEED can’t be set in AUTO mode.

FAN Mode

  1. Press the MODE button to select FAN mode.
  2. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH.
  3. Press the ON/OFF button to start the unit.

NOTE: You can’t set temperature in FAN mode. As a result, your remote control’s LCD screen will not display temperature.

DRY Mode (dehumidifying)

  1. Press the MODE button to select DRY.
  2. Set your desired temperature using the TEMP ▲ or TEMP ▼ button.
  3. Press the ON/OFF button to start the unit.

NOTE: FAN SPEED cannot be changed in DRY mode.

Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.

TIMER ON setting

TIMER OFF setting

NOTE:

  1. When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
  2. Cancel either function by setting its timer to 0.0h.

TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours after the current time.

Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.

How to Use Advanced Functions

Swing function
Press Swing button

The horizontal louver will swing up and down automatically when pressing Swing button. Press again to make it stop.

Keep pressing this button more than 2 seconds, the vertical louver swing function is activated. (Model dependent)

Airflow direction

Each time you press the button, it will adjust the louver by 6 °. Press the button until the direction you prefer is reached.

LED DISPLAY

Press this button to turn on and turn off the display on the indoor unit.

Keep pressing this button more than 5 seconds, the indoor unit will display the actual room temperature. Press more than 5 seconds again will revert back to display the setting temperature.

ECO function

Press this button under COOL Mode to enter the energy efficient mode.
Note: This function is only available under COOL mode.

Under cooling mode, press this button, the remote controller will adjust the temperature automatically to 24 ºC/75 ºF, fan speed of Auto to save energy (only when the set temperature is less than 24 ºC/75 ºF). If the set temperature is above 24 ºC/75 ºF, press the ECO button, the fan speed will change to Auto, the set temperature will remain unchanged.

NOTE:
Pressing the ECO button, or modifying the mode or adjusting the set temperature to less than 24 ºC/75 ºF will stop ECO operation.
Under ECO operation, the set tmeperature should be 24 ºC/75 ºF or above, it may result in insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.

SLEEP function

The SLEEP function is used to automatically adjust the temperature to achieve sleep comfort(and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control.The sleep function is not available in Fan or Dry mode.Please refer to the OPERATION & INSTALLATION MANUAL for more details.

Silence function

Keep pressing Fan button for more than 2 seconds to activate/disable Silence function(some units).
Due to low frequency operation of compressor, it may result in insufficient cooling capacity.
Press ON/OFF, Mode, Sleep, Turbo or Clean button while operating will cancel silence function.

Special Avowal

  1. The information above has been checked; our company reserves the hermeneutic power to any print errors or misunderstanding on the content.
  2. Any technology improvement will add into new instruction without any prior notices. The product appearance and color refer to the practical air conditioner.
  3. The e-copy of user manual can be sent by e-mail on requested, please call Shun Hing Electric Works & Engineering Co. Ltd. hotline at 2861 2767.

After sale service
Guarantee period state from the date of purchasing to one year. If the product is damaged under proper use, a free repair service is available. Please present the Official invoice and the guarantee certificate with the sales point’s chop / redemption center’s chop for free maintenance.For enquiries, please contact Shun Hing Electric service Centre Limited hotline at 2406 5666.

Turn off the power and contact Shun Hing Electric Service Centre Ltd. as soon as any of the following events occur.
The circuit breaker frequently trips or the fuse blows regularly.
lf water or foreign objects have accidentally entered the air conditioner.
lf there is abnormal sound during operation.

SHUN HING ELECTRIC WORKS & ENGINEERING CO., LTD
OFFICE: 9/F, PENINSULA CENTRE, 67 MODY ROAD, TSIMSHATSUI EAST, KOWLOON, HONG KONG
TEL: (852) 2861 2767
FAX: (852) 2865 6706
WEBSITE: www.rasonic.com
EMAIL: shew@shunhinggroup.com
MAINTENANCE AND REPAIR SERVICE
SHUN HING ELECTRIC SERVICE CENTRE LTD.
OFFICE: 11TH FLOOR, SHUN HING CENTRE, 2 SHING YIU STREET, KWAI CHUNG, NEW TERRITORIES, HONG KONG
TEL: (852) 2406 5666
FAX: (852) 2408 0316
WEBSITE: www.shesc.com
ACCESSORIES SALES HOTLINE
TEL: (852) 2406 5666
CUSTOMER SERVICE CENTRES
IST FLOOR, SHUN HING CENTRE, 2 SHING YIU STREET, KWAI CHUNG, NEW TERRITORIES, HONG KONG
TEL: (852) 2406 5439
FAX: (852) 2408 1389
AVENIDA DE VENCESLAU DE MORAIS, NO. 193-199, 5 ANDAR-I, EDF. INDUSTRIAL NAM LENG, MACAU
TEL: (853) 2836 2928
FAX: (853) 2833 6405
For the latest information of customer service centres, please visit www.shesc.com or call us at our hotline.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals