Safety warnings

  • Before installing the lock, please read carefully the instructions below.
  • For a correct understanding of the technical terms and of the connection scheme, we recommend that you make your lock installed by a qualified technician, in order to avoid the inconveniences created by the incorrect connection of the electric lock.

Main features

  • Mechanical operation method: Fail Secure (normally closed). The electric lock keeps the door closed when not powered
  • Recessed mounting, indoor or outdoor
  • Power failure status: closed
  • Material: stainless steel and zinc alloy (YS800), steel and zinc alloy (YS810)
  • Closing force: 250 kg
  • Power supply: 12V DC impulse or timing (1-3 seconds)
  • Equipped with central reinforcement pin (with retention function)
  • Manual lock function on open mode
  • Current: 1.2A
  • Operating temperature: -26°C ~ + 80°C
  • Compatible with video door phones and access control systems
  • Universal. Recommended for doors opening inwards or outwards, on the left or on the right.

Connection instructions

The accessories of the product include a diode that, connected, prevents current shocks transmitted to the access control system in case of incorrect closing of the electric lock. It is recommended that the diode be connected in parallel with the lock connections.
The electric lock can be controlled by a NO circuit (normally open) that offers a 12V voltage either pulse type (if the retention function is applied) or timed type (maximum 1-3 seconds).
The retaining function is active if the central pin inside the electric lock (see picture below) is pressed by the bolt of the door lock when the door is closed.
This function allows the lock to be locked open until the door is opened.
YS810

  1. Reinforcement pin
  2. Manual lock pin

Installation note

To open the door normally, leave 1-2 mm between the door lock bolt and the electric lock bolt and 3-5 mm between the front plate of the electric lock and the door lock plate.
Installation

  1. Electric lock YS800/YS810
  2. Door lock bolt

Connection Example

Connection example

  • A. Electric locks Fail Secure type
  • B. Electromagnetic lock Fail Safe type
  • C. Automatic lock with bolt Fail Safe type
  • D. PNI DK110 access control keyboard
  • E. SilverCloud PB303 access button
  • F. PNI K80 power source with timer

Simplified EU declaration of conformity

SC ONLINESHOP SRL declares that Electric lock SilverCloud YS810/ SilverCloud YS800 is in accordance with the EMC Directive 2014/30/EU and the ROHS Directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the foll owing website: