T4815 Ballast Bypass LED Feit Electric Installation Guide

June 9, 2024
Feit Electric

Ballast Bypass LED Feit Electric
Installation GuideT4815 Ballast Bypass LED Feit Electric - Figure
2

Safety Information

PLEASE READ THE INSTRUCTIONS AND WARNINGS LISTED BELOW PRIOR TO INSTALLATION.
THIS LAMP IS INTENDED TO WORK WITH THE EXISTING ELECTRONIC BALLAST OR YOU CAN BYPASS THE BALLAST AND REMOVE IT FROM  THE ELECTRICAL CIRCUIT. WHEN BYPASSING A BALLAST ALWAYS HAVE A QUALIFIED ELECTRICIAN DO YOUR ELECTIRCAL WORK.
This LED tube is intended to replace fluorescent tube lamps with ANSI designation F32T8 with G13 base.

  1. Always follow basic safety precautions to reduce the risk of fire, electric shock and personal injury.

  2. WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

  3. WARNING: RISK OF SHOCK: House electric current can cause painful shock or serious injury unless handed properly. For your safety, always remember to:
    A. Turn OFF the power supply at the fuse or circuit breaker box before you install the lamp.
    B. Ensure the fixture is grounded to avoid potential electric shock and to ensure reliable starting.
    C. Wear rubber sole shoes, work on a sturdy ladder and don’t touch with wet hands.
    D. This lamp is not intended for use with emergency exits or emergency lights.
    E. Do not make or alter any open holes in the enclosure of wiring or electrical components during kit installation.
    F. Before installation is complete, double check all connections to be sure they are tight and correct.
    G. Only use UL or IEC approved wire for input/output connections.

  4. Avoid looking directly into the lamp.

  5. Do not install this in a pre-heat luninaire (fixture), often with external starters.

  6. This lamp is designed for use in a circuit protected by a fuse or circuit breaker. It is also designed to be installed in accordance with local electrical codes. If you are  unsure about your wiring, consult a qualified electrician or local electrical inspector, and check your local electrical code.

  7. WARNING: RISK OF CUTS: To prevent wiring damage, abrasion or cuts, do not expose wiring to edges of sheet metal or other sharp objects and wear gloves.

  8.  Account for small parts and destroy packaging material, as these may be hazardous to children.

WARNING: Use only on 120-277 volt 60Hz circuits.
Suitable for damp locations. Do not use with dimmers. Do not touch lamp pins to the metal housing when installing.
WARNING: If lamp or luminaire exhibit abnormal operation (buzzing, flickering, minimal or no light, etc.), immediately turn off power and contact us for more  information.
WARNING: Examine the luminaire (fixture) carefully before installing the lamp. Ensure the electrical lampholders (sockets) are not damaged and will make firm  contact with the lamp pins. Replace damaged parts as necessary.
WARNING: Risk of fire or electric shock. LED retrofit kit installation requires knowledge of luminaire’s electrical system. If not qualified, do not attempt installation.  Contact a qualified electrician. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the  rating of the retrofit kit does not exceed the input rating of the luminaire.
WARNING: The retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by authorities having jurisdiction.  Product must be installed by a qualified electrician in accordance with the applicable and appropriate electrical codes. The installation guide does not supersede local or  national regulations for electrical installations.

Thank you for your purchase. Questions, comments or feedback? We’d love to hear from you.
Visit feit.com/help for support.

Limited Warranty

This product is warrantied to be free from defects in workmanship and materials for up to 5 years from date of purchase.
If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact-us for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES  ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY  EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the  limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can  radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause  harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference  by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment  into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or  modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Supplier’s Declaration of Conformity:
47 CFR § 2.1077 Compliance Information
Responsible Party: Feit Electric Company
4901 Gregg Road, Pico Rivera, CA 90660, USA

Direct Replacement/Plug & Play Installation Instructions (Type A)

THIS PRODUCT MAY NOT BE COMPATIBLE WITH ALL BALLASTS.
FOR MORE INFORMATION ABOUT BALLAST COMPATIBILITY PLEASE VISIT WWW.FEIT.COM.

  1. Turn off the power at the switch and fuse box or circuit breaker.

  2. Remove existing fluorescent lamp(s) from the fixture. Replace with Feit Electric T 4815/840/AB/LED LED lamp.
    T4815 Ballast Bypass LED Feit Electric - Figure 2

  3. Turn on the power at the fuse box or circuit breaker and at the switch and enjoy your new Feit Electric LED lamp.

Bypass Assembly Instructions (Type B)

Scan QR Code for ballast bypass instructions.

https://vimeo.com/579973279

  1. Turn off the power at the switch and fuse box or circuit breaker.

  2. Cut the incoming and outgoing power wires approximately two inches from the ballast.
    T4815 Ballast Bypass LED Feit Electric - Figure 4

  3. After removing the existing ballast, connect the live wire (L) to the wire coming from the lamp holder terminal. Next, connect the neutral wire (N) to the wire coming  from the lamp holder terminal on the other side/end.
    NOTE: Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. instead installers should cut  existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
    T4815 Ballast Bypass LED Feit Electric - Figure 5

  4. Install the Feit T 4815/840/AB/LED LED tube.
    T4815 Ballast Bypass LED Feit Electric - Figure 6

  5. Turn on the power and enjoy your new Feit T 4815/840/AB/LED tube.

  6. After wiring modification is completed, attach the replacement cautionary label onto a visible place on the fixture that is kept visible after the installation of tubes.  Remove any pre-existing labels.

WARNING!
USE LED LAMPS ONLY. THIS LUMINAIRE HAS BEEN MODIFIED TO USE LED LAMPS AND CAN NO LONGER OPERATE THE ORGINALLY  INTENDED FLUORESCENT LAMPS SAFELY.
FLUORESCENT LAMPS COULD BREAK AND CAUSE PERSONAL INJURY IF USED IN THIS FIXTURE.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Feit Electric User Manuals

Related Manuals