GENERAL WARNINGS

  • Risk of electric shock — This device contains electronic components that operate via a power source (batteries). Children should only use the device under adult supervision. Only use the device as described in the manual; otherwise, you run the risk of an electric shock.

  • Choking hazard — Children should only use the device under adult supervision. Keep packaging material, like plastic bags and rubber bands, out of the reach of children, as these materials pose a choking hazard.

  • Risk of chemical burn — Keep batteries out of the reach of children! Make sure you insert the batteries correctly. Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately with a plenty of water and seek medical attention.

  • Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire.
    Excessive heat or improper handling could trigger a short-circuit, a fire, or an explosion.

  • Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.

  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. The batteries should be removed from the unit if it has not been used for a long time.

SCOPE OF DELIVERY
Sensor, Operating instructions, 3x AA batteries.

BEFORE YOU BEGIN

  • We recommend using alkaline batteries. If temperatures regularly fall below 0°C (32°F), we recom-mend using lithium batteries.
  • Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements.)
  • Insert batteries before first use, matching the polarity in the battery compartment.
    3x AA batteries are required.

EC Declaration of Conformity
Hereby, Bresser GmbH declares that the equipment type with part number: 7009970 is in compliance with Directive: 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/download/7009970/CE/7009970_CE.pdf

UKCA DECLARATION OF CONFORMITY
Bresser UK Ltd. has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address: www.bresser.de/download/7009970/UKCA/7009970_UKCA.pdf

Bresser UK Ltd.

  • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain

NOTES ON CLEANING

  • Remove the batteries before cleaning.
  • Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
  • Protect the device from dust and moisture.

OVERVIEW

BRESSER 7009970 Air Quality Sensor - OVERVIEW

1. LCD display
2. [MODE] key
3. [CHECK] key
4. Wall mounting holder| 5. [CH1~4] slide switch
6. [RESET] key
7. Battery compartment
8. DC adapter USB power port
---|---

BATTERY INSERTION

  1. Unscrew and remove the battery door of sensor with a screwdriver
  2. Insert the 3 rechargeable batteries (included) into the battery compartment in the following order:BRESSER 7009970 Air Quality Sensor - following order
  3. Screw the battery door compartment on tightly.
  4. After inserting batteries, all LCD segment will be shown for 1 second.

Note:
– Please prepare a screwdriver for removing and close the battery door.

GETTING STARTED

  1. Slide [CHANNEL] to set the channel number for your sensor(s).
  2. Use a pin to press [RESET] key for run the channel number.

Note:
– If there are more than one sensor in use, ensure to assign different channel numbers for each sensor to enable the measurement to displayed correctly on the console (purchase of separately).

LCD DISPLAY

  1. PM2.5/PM10 display mode
  2. PM2.5 / PM10 concentration value
  3. PM2.5 / PM10 concentration level
  4. Sensor Wireless channel number
  5. Transmission signal
  6. Battery power indicator

BRESSER 7009970 Air Quality Sensor - LCD DISPLAY

DISPLAY MODE
Press [MODE] to toggle the display mode between PM10 and PM2.5.

MEASUREMENT INTERVAL

Powered by DC adapter
The device measures PM2.5 or PM10 concentration every minute automatically when powered with a DC adapter.
Manual detection
User can press [CHECK] button anytime to get an updated measurement of PM2.5 or PM10 concentration readings. (It takes approximate 10-12s to detect, the readings indicated by blinking PM2.5/PM10 icon.)
Operated by batteries
When powered by batteries, it’s detecting every 10 minutes by default. To maximize the battery life, user can also change the detection interval from 10 minutes to 20 or 30 minutes.

Setting default mearurement interval

  1. Press and hold [CHECK] for 2 seconds until the display is flashing
  2. Press [MODE] to choose which interval time.
  3. The setting sequence: 10m ‣ 20m ‣ 30m
  4. Press [CHECK] to finish the setting and go back to normal display.
Detection interval (Minute) Description
1 (when connected to adapter) 10 (default) The sensor will detect the PM

value every 1 minute
20| The sensor will detect the PM value every 10 minutes
30| The sensor will detect the PM value every 20 minutes
| The sensor will detect the PM value every 30 minutes

PM2.5/PM10 CONCENTRATION

For easy visualization of air quality, the device spreads the concentration readings over 6 level scale.

BRESSER 7009970 Air Quality Sensor - CONCENTRATION

The following provides some given health guidelines on activities between good and hazardous air quality*:

Good ↔ Hazardous

PM2.5| PM10| Healthy persons| Elderly, Children, Pregnant Women| Persons with chronic disea-se or heart disease
---|---|---|---|---
0-35| 0-35| Continue with normal activities| Continue with normal activities| Continue with normal activities
36-53| 51-75| Continue with normal activities| Continue with normal activities| Continue with normal activities
54-70| 76-100| Reduce prolonged or strenuous outdoor physical exertion| Minimize prolonged or strenuous outdoor physical exertion| Minimize prolonged or strenuous outdoor physical exertion
71-150| 101-350| Avoid prolonged or strenuous outdoor physical exertion| Minimize outdoor activity| Avoid outdoor activity
151-250| 351-420| Minimize outdoor activity| Avoid outdoor activity| Avoid outdoor activity
251+| 420+| Avoid outdoor activity| Avoid outdoor activity| Avoid outdoor activity

  • Always consult/check with your doctors for any medical advices concerning the air quality and your health.
    Note:
    This 6 level scale of PM2.5 / PM10 concentration is not the same as Air Quality Index (AQI).

BATTERY POWER STATUS
The device is powered by rechargeable batteries, and comes with battery power indicator.
The battery life of the device from fully charged batteries is determined by the number of detections it performed, either through set intervals or manually activated by user.

BRESSER 7009970 Air Quality Sensor - BATTERY POWER
STATUS

When battery power fails to below 20%, user should recharge the batteries by connecting to a USB port using the cable provided.
Note:
When the wireless PM2.5/PM10 air quality sensor’s battery power is below 20%, its detection function will temporary suspension.

CHARGING BATTERY
You can use the micro USB cable to charge the wireless PM2.5/PM10 sensor if the battery states show in “Low battery”. When Micro USB port plug in the micro USB cable for charging, the LCD will display and flashing battery icon.

BRESSER 7009970 Air Quality Sensor - CHARGING BATTERY

Note:
– Charged to full capacity from <20% battery power status require 24 hours.

REPLACE THE RECHARGEABLE BATTERIES
Over time, the batteries may degrade in terms of holding the highest capacity for which it was designed for. If you find the device´s battery power is not lasting as it used to be, it´s probably a good time to change them.

  1. Unscrew and remove the battery door of sensor with a screwdriver.BRESSER 7009970 Air Quality Sensor - remove the battery
  2. Pull the black ribbon lying under the batteries. All batteries can be removed together.BRESSER 7009970 Air Quality Sensor - Pull the black ribbon 
  3. Insert new 3 x AA size rechargeable batteries into the battery compartment according to the polarity mark inside battery compartment.
  4. Screw the battery door compartment on tightly.
  5. After inserting batteries, all LCD segment will be shown for 1 second.

Note:
Please prepare a screwdriver for removing and close the battery door.
PAIRING WIRELESS SENSORS TO CONSOLE DISPLAY
This Wireless PM2.5/PM10 Air Quality Sensor can connect to the Air Quality Display console.

  1. After powering up the wireless air quality sensor, it will automatically enter registration mode for 10 minutes until which it can be paired by the display console.
  2. Once the connection is successful, the signal strength indication  and PM2.5/PM10 infromation will appear on the display console.

Note:
– If you need to re-assign the sensor channel, slide the channel slide switch to the new cahnnel position, then use a pin to press [RESET] key to restart the sensor.
– To avoid the sensor(s) and console pairing failure during new channel number assigned and setup, please power up the sensor(s) first, and then press [SENSOR] key on the main unit.
– After connected to the console display, the reading will transmit every 12 seconds in the first 5 minutes. Every reading transmission, the symbol of signal transmission , will flash 0.5 seconds at once.

VIEW DATA ON CONSOLE
You can view the readings of your PM2.5/PM10 sensor(s) on the console receiver to which the sensor(s) is linked to. Readings can then be analyzed into averages of past 24 hours or maximums of past 1 hour, 24 hours, or since its last reset.
DATA TRANSMISSION
The device transmits its updated reading at fixed interval of 60 seconds to the paired console receiver.
RESET THE SENSOR
In case of malfunction, use a pin to press [RESET] button to reset the sensor.

SENSOR INSTALLATION

The sensor is designed for desktop or wall mount for easy viewing. Follow the guidelines below for the sensor placement.

  1. Choose an open area away from any emissions source of pollutants, heat source, or with air flow greater than 1m/s.
  2. Place the wireless PM2.5/PM10 sensor at least 1.5m to 4m above the ground to better illustrate the detection of air quality in the human breathing zone.
  3. Do not expose the sensor to direct sunlight.

Wall mounting
Sensor can be mounted on the wall at different angle, either at slant angle or vertically with the mounting adapter (included).

Place a screw on the wall where you wish to hang for sensor. Hand the sensor on to the screw with or without the mounting adaptor.BRESSER 7009970 Air
Quality Sensor - Vertical angle

Note:
– Higher sitting may also be appropriate if the sensor is representative of a large area.

SPECIFICATIONS

WIRELESS PM2.5/PM10 AIR QUALITY SENSOR

Dimensions (W x H x D) 82 x 120.5 x 41mm (3.2 x 4.7 x 1.6 in)
Main power •3x AA size 1.2V NiMH rechargeable batteries

•USB charging (5V1A)
•1m/1.2m USB charging cable included
Operating temperature range| -10°C to 40°C (-14°F to 140°F)
Operating humidity range| Rh 1% to 90%
PM2.5/pm 10 Unit| ug/m 3
RF frequency| •868MHz for EU/UK version
Maximum transmitting power| < 20 mW
RF transmission range| 150 meters (490 feet) line of sight
Number of channels| 4 (Ch1-4)
Detection interval| 1 minute, 10 minutes (defualt), 20 minutes, 30 minutes
Transmission interval| 60 seconds
Mass concentration precision| PM2.5:
•±15 pg/m3 @ 0 to 100 pg/m3 (at 25°C)
•±15% @ 100 to 1000 pg/m3 (at 25°C ±5°C)
PM10:
•±30 pg/m3 @ 0 to 100 pg/m3 (at 25°C)
•±30% @ 100 to 1000 pg/m3 (at 25°C ±5°C)
Mass concentration range| 1 to 1000 pg/m3
Mass concentration resolution| 1 pg/m3
Particle detection size range| •Mass concentration: PM2.5 and PM10
•Number concentration: PM2.5 and PM10
Lower limit of detection| 0.3 pm

DISPOSAL
Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.
Do not dispose of electronic devices in the household garbage!
As per the Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.
In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive. Batteries that contain toxins are marked with a sign and a chemical symbol.

1 battery contains cadmium
2 battery contains mercury
3 battery contains lead

WARRANTY & SERVICE

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms as well as information on details of our services at www.bresser.de/warranty_terms.
Would you like detailed instructions for this product in a particular language? Then visit our website via the link below (QR code) for available versions. Alternatively you can also send an email to [email protected] or leave a message on +49 (0) 28 72  – 80 74-220.  Please always state your name, precise address, a valid phone number and email
address, as well as the article number and name.
Number charged at local rates in Germany (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.

MANUAL DOWNLOAD: SERVICE AND WARRANTY:

BRESSER 7009970 Air Quality Sensor - qr1| BRESSER
7009970 Air Quality Sensor - qr2
www.bresser.de/P7009970| www.bresser.de/warranty_terms

BRESSER logoBresser GmbH
Gutenbergstr. 2 · DE-46414 Rhede · Germany
www.bresser.de · [email protected]
Bresser UK Ltd.
Suite 3G, Eden House, Enterprise Way,
Edenbridge, Kent TN8 6HF, Great Britain
Errors and technical changes reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals