BRESSER 5802520 Biorit ICD CS Stereo Microscope LED Instruction Manual
- June 9, 2024
- BRESSER
Table of Contents
- Scope of delivery
- Parts overview
- Finding the right location for observation
- Assembly
- Observation
- Diopter adjustment
- Replacing the objective
- Replacing the eyepieces
- Exchange of the fuse
- Care and maintenance
- Technical data
- Disposal
- Declaration of Conformity
- Warranty & Service
- Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BRESSER 5802520 Biorit ICD CS Stereo Microscope LED
Visit our website via the following QR Code or web link to find further information on this product or the available translations of these instructions.
WARRANTY
CAUTION!
To work with this microscope, sharp and pointed aids are being used. Please
take care that this microscope and its accessories are stored at a place out
of reach of children. Let children only work with this microscope under an
adult’s supervision! Keep packing material (plastic bags etc.) away from
children!
Scope of delivery
Stereo microscope ( A ), interchangeable objectives ( B ): 1.0x (Art.
No. 5802520) or 0.5x/1.0x/2.0x (Art. No. 5802530), 1 pair of WF10x eyepieces (
C ), 1 pair of rubber eyecups ( D ), power cable (E), spare fuse
(F), dust cover ( G ), Instruction manual ( H )
Also required (not included):
small Philipps screwdriver, small flathead screwdriver
Parts overview
❶ Eyepieces
❷ Diopter adjustment ring
❸ Objective with clamping screw (3a)
❹ Front microscope arm
❺ Microscope pole
❻ Rear microscope arm
❼ Locking ring
❽ Microscope base
❾ Connecting screw
❿ Lock nut
⓫ Focusing wheel
⓬ Illumination
⓭ Power socket
⓮ Fuse holder
⓯ On/Off switch
⓰ Rubber eyecup
⓱ replacement fuse (F2AL250V)
Finding the right location for observation
Dry and dust free, room temperature between -5 and +40°C.
Position your device so that it can be disconnected from the power supply at
any time. The wall socket should always be located near the device and be
easily accessible, since the plug on the power cord serves as a disconnecting
device for the power supply.
Assembly
- Place the base (8) on a stable surface.
- Attach the rear microscope arm (6) to the pole of the microscope base.
- Use the locking ring (7) to secure the microscope arm.
- Connect the front part of the microscope arm (4) to the rear arm. Insert the connecting screw (9) through the hole in the rear microscope arm. Take care that the flattened edge shows backwards. Now attach the the front microscope arm to the screw. Tighten the lock nut (10) with the lever until the front microscope arm does not tilt down.
- Connect the power cable to the power connector (13) of the microscope and a free power outlet.
Observation
Turn on the microscope using the power switch (15).
Now, look through the eyepieces (1) of the binocular viewing and change the
spacing between the eyepieces so that you get a round, clear field of view.
The definition is adjusted by slowly turning the focusing wheel (11).
If you have to observe a very large or very small object, you can adjust the
microscope. Loosen the holding screw on the side and move appropriately the
microscope head on its guidance. If you have found the correct position
(distance of 22 cm from the object), tighten the holding screw again.
Diopter adjustment
Turn the left diopter adjustment ring (2) on the left eyepiece to the central position (silver marking). Shut your left eye and look with the right eye through the right eyepiece. Now focus with the focusing wheel (11), focus correctly for your right eye. Now, look with your left eye through the left eyepiece. If the image isn’t sharp, adjust the focus for your left eye by turning the diopter adjustment ring. Now, the microscope is correctly adjusted.
Replacing the objective
Note : The objective of this stereo microscope can be replaced. Depending on the model, additional interchangeable objectives are included or can be purchased as optional accessories. Hold the mounted objective (3) firmly with one hand and use a small flathead screwdriver to loosen the slotted screw (3a). Remove the objective from the holder. Place the desired interchangeable objective on the holder and screw it on with the slotted screw as well.
Replacing the eyepieces
Note : The eyepieces of this stereo microscope can be replaced. Depending on the model, additional eyepieces are included or can be purchased as optional accessories.
Use a small Phillips screwdriver to unscrew the cross screws on the two eyepiece holders. Remove the eyepieces from the holders and insert others. Screw them on with the cross screws as well.
Exchange of the fuse
Switch off the microscope and pull out the plug of the power outlet. Grip with a small screwdriver under the lug of the fuse holder (14) and pull it carefully forward. Take out the fuse and change it into a new one (17). Install the fuse holder and plug again.
Care and maintenance
Cleaning the lenses
Sweep the lens with a lens tissue or soft fabric immersed with a small amount of alcohol (e.g. isopropanol).
Cleaning the painted parts
The dust on the painted parts can be removed by cleaning cloth. For the grease spots, the gauze immersed slightly with aviation gasoline is recommended. Do not use organic solvents such as alcohol, ether or other thinner etc. for cleaning the painted parts or plastic components. Your microscope is a high- quality optical instrument. Avoid disassembling the microscope. Improper disassembling affects the high utility of the microscope. Moreover, the warranty expires. Cover the microscope with the dust protective cover and place it there, where it is dry and dust-free. We suggest the storage of all objectives and eyepieces in a closed container with drying agent.
Technical data
|
Art. No. 5802520
|
Art. No. 5802530
---|---|---
Magnification:|
10x
|
5x/10x/20x
Working distance:|
230 mm
|
250 mm (5x)/230 mm (10x)/80 mm (20x)
Power supply:|
230V / 50HZ via power cable
Surge protection:|
with fine fuse, type F2AL250V
Illumination:|
LED, long-life, not exchangeable
Eyepiece holder:|
30.5 mm
Disposal
| Dispose of the packaging materials properly, according to their type, such
as paper or cardboard. Contact your local waste-disposal service or
environmental authority for information on the proper disposal.
---|---
| Do not dispose of electric equipment together with household waste material!
In observance of European Directive 2012/19/EC on waste electrical and
electronic equipment (WEEE) and its implementation in accordance with national
law, electric equipment that have reached the end of its life must be
collected separately and returned to an environmentally compatible recycling
facility.
Declaration of Conformity
CE Declaration of Conformity
| Bresser GmbH has formed a „CE Conformity Declaration“ in line with the
applicable directive. This declaration is available for review under
https://www.bresser.de/download/5802520/CE/5802520_CE.pdf
https://www.bresser.de/download/5802530/CE/5802530_CE.pdf
---|---
UKCA Declaration of Conformity
| Bresser UK Ltd. has formed a „UKCA Declaration of Conformity“ in line with
the applicable directive. This declaration is available for review under
https://www.bresser.de/download/5802520/UKCA/5802520_UKCA.pdf
https://www.bresser.de/download/5802530/UKCA/5802530_UKCA.pdf
---|---
Warranty & Service
The regular warranty period is 2 years and begins on the day of purchase. To
benefit from an extended voluntary guarantee period as stated on the gift box,
registration on our website is required.
You can consult the full warranty terms as well as information on extending
the warranty period and details of our services at
www.bresser.de/warranty_terms.
Service
Please contact the service centre first for any questions regarding the
product or claims, preferably by e-mail.
E – Mail : service@bresseruk.com
Telephone *: +44 1342 837 098
Number charged at local rates in the UK (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.
@BresserEurope
References
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- Bresser | BRESSER Biorit ICD CS Stereomikroskop LED | Expand Your Horizon
- Bresser | BRESSER Biorit ICD-CS 5x-20x Auflicht Mikroskop LED (30.5) | Expand Your Horizon
- Bresser UK | Home page | Online optics and electronics to explore the world around us.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>