Here are the tools you’ll need to complete your installation:
| | |
---|---|---|---
Ladder
| Screwdriver| Pliers|
Wire Strippers
INSTALLATION INSTRUCTIONS
WARNING
- To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
- The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
- All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.
READ AND SAVE THESE INSTRUCTIONS
These instructions are provided for your safety. It is very important that
they are read carefully and completely before beginning installation of the
lighting fixture.
PREPARING FOR INSTALLATION
Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. One end of the threaded post (H) should be attached to the mounting bracket (A) with a hex nut (G) in place. The other end should be connected to the canopy loop (E). Unscrew the canopy loop ring (F) from the canopy loop (E). Depending on the placement of your junction box the position of threaded post (H) may need to be adjusted to allow the canopy to be flush with the ceiling. Determine this by lifting mounting bracket (A) up to the junction box and place canopy (D) over the canopy loop (E), so that it is flush with the ceiling. Adjust the position of threaded post (H) on the mounting bracket (A) so that the canopy (D) covers at least half of the exterior threads on the canopy loop (E) while it is securely connected to threaded post (H). The threaded post (H) can be adjusted by loosening hex nut (G) to allow movement of threaded post (H) on mounting bracket (A). Once the ideal position of the threaded post (H) is determined, tighten up the hex nuts (G) onto the threaded post (H) just beneath the mounting bracket (A) to secure the threaded post in place.
ASSEMBLING THE FIXTURE
There are four 12-inch rods (I), and one 6-inch rod (J) included for each
fixture. Determine the correct number of rods needed for proper hanging
height. To lengthen the fixture, add additional rods. To shorten the fixture,
trim the wires to desired length. Leave at least 8 to 10 inches of wire in
addition to the desired length and slide any excess rods off the fixture’s
wiring to discard. Keep in mind that you must use at least one rod to hang the
fixture. Thread the wires through the rods and pull the wires until taut
before connecting the rods together. Screw rod onto post (K) on the fixture.
Carefully install glass (L) inside the frame (M), resting the bottom edge in
the channel and securely locking the top of the glass with the bendable tabs
on the fixture. Repeat for each piece of glass. Pull the fixture wires through
the canopy loop ring (F), the top of canopy (D), and canopy loop (E). Screw
the top rod to canopy loop (E). Have a helper support the fixture’s weight and
attach the mounting bracket (A) to the junction box by securely tightening the
mounting screws (B).
CONNECTING THE WIRES
Attach the fixture’s wires to the power supply wires from the junction box.
Connect black to black (Live); white to white (grounded); grounding to
grounding (green or copper). Twist the ends of the wire pairs together. Then,
twist on a wire connector. Make sure all twists are in the same direction.
Loop fixture’s ground wire around grounding screw (C) and tighten. If there is
no ground wire (green or copper) from the junction box, contact a qualified
electrician.
FINISHING THE INSTALLATION
Place the canopy (D) flush to the ceiling and slide the canopy loop ring (F)
up beneath the canopy. Tightly screw canopy loop ring (F) onto the canopy loop
(E) to properly secure the canopy (D) in place. Install light bulbs (not
included) in accordance with the fixture’s specifications. Do not exceed the
recommended wattage. Your installation is now completed. Turn on the power and
test the fixture.
CLEANING TIPS
Treat the fixture gently! Regular cleaning will reduce the need for deep
cleaning. For regular cleaning, turn off the light and wipe down the fixture
with a clean lint-free cotton or microfiber cloth. Never spray cleaner
directly onto the fixture.
NOTICE
In order to use a 12in rod by itself you must first remove the post from the
6in rod and install it on one of the ends of the 12in rod.
Hunter Pro Tip:
Twist or tape wire ends together to make it easier to pass them through the
downrods. Threaded post may also be removed for easier wire access.
4 Light Pendant
Fixture weight ±2 lbs: 20 lbs (9.07 kg)
Hardware Service Kit
Part # | Model | Finish |
---|---|---|
KD80101L08 | 19371 | Rustic Iron |
KD80101L19 | 19372 | Textured Rust |
Glass
Part # | Model | Type |
---|---|---|
KD54401046 | 19371 | |
19372 | Clear Seeded Glass |
©2022 Hunter Fan Co. ML233
r_013122
Documents / Resources
|
Hunter 19371 4 Light
Pendant
[pdf] Instruction Manual
19371, 19372, 19371 4 Light Pendant, 19371, 4 Light Pendant, Light Pendant,
Pendant
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>