For Models: 19900,19901HUNTER 19900 Maple Park 3 Light Linear
Cluster Light Cluster
Fixture weight ±2 lbs:
Peso ±2 lb:
Poids fixe ±2 lbs: 10.1 lbs (4.58 kg)HUNTER 19900 Maple Park 3 Light
Linear Cluster - fig

PREPARING FOR INSTALLATION

Carefully remove all contents from the carton keeping the glass shades in their Styrofoam tray until installation is complete to prevent glass breakage. Shut off the power at the circuit breaker and completely remove the old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. Remove cap nuts (G) from mounting screws (A). Put the drywall anchor (H) inside the hole in the ceiling. Place the mounting plate (B) over the junction box so that mounting screws (A) extend out away from the ceiling. Depending on the placement of your junction box the position of mounting screws (A) may need to be adjusted to allow the canopy to be flush with the ceiling. Adjust the position of mounting screws (A) so that mounting screws (A) can be exposed 5-6 mm after passing through the canopy (F) to properly fit the cap nuts. Mounting screws (A) can be adjusted by loosening nuts (C) and loosening or tightening mounting screws (A). Once the ideal position of mounting screws (A) has been confirmed, tighten nuts (C) on mounting screws (A) on the front of the mounting plate to ensure that mounting screws (A) are secure. Pull the house wires through the center of the mounting plate (B). Secure mounting plate (B) to the junction box by tightening the screws (D) and then inserting the drywall screw (I) through the mounting plate (B) into the drywall anchor (H).

CONNECTING THE WIRES

Slide cord (L) through cord grip (K) to adjust the wire to the desirable length [set screw (M) may need to be loosened first]. Tighten the set screw (M) with the included screwdriver (O) to lock it tight. Adjust the placement of the strain relief (N) on the cord above the canopy. Cut excess cord leaving enough length to reach from each end to the center cord to assure that the connections of each of the 3 cords and house wiring can be made. Remove the outer jacket of each cord (L) to expose individual wires (white, black, green). Strip half an inch of the jacket away from the ends of each individual wire. Have a helper support the fixture’s weight while completing the wiring. Attach the fixture’s wires [from all 3 cords (L)] to the power supply wires from the junction box. Connect black to black (Live); white to white (grounded); grounding to grounding (green or copper). Twist the ends of the wire pairs together. Then, twist on a wire connector. Make sure all twists are in the same direction. Loop fixture’s ground wire around grounding screw (E) and tighten. If there is no ground wire (green or copper) from the junction box, contact a qualified electrician.

FINISHING THE INSTALLATION

Raise canopy (F) to mounting plate (B) and position mounting screws (A) so that they protrude through the openings of the canopy (F). Secure canopy (F) in place with cap nuts (G). Carefully remove glass shades from their Styrofoam tray. Install light bulbs (not included) in accordance with the fixture’s specifications. Do not exceed the recommended wattage. Your installation is now complete. Turn on the power and test the fixture.

CLEANING TIPS

Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray cleaner directly onto the fixture.
NOTICE
Drill 9/64″ pilot holes in the support structure to aid in securing the light fixtures .

Hardware Service Kit

Part #| Model| Finish
KE18001834| 19900| Noble Bronze
KE18001214| 19901| Brushed Nickel

Here are the tools you’ll need to complete  your installation:

| | | |
---|---|---|---|---
Ladder| Screwdriver| Pliers| Wire Strippers| Drill

INSTALLATION INSTRUCTIONS

WARNING

  • To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
  • The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
  • All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.

©2021 Hunter Fan Co.
ML185
r111921

Documents / Resources

| HUNTER 19900 Maple Park 3 Light Linear Cluster [pdf] User Guide
19900, 19901, 3 Light Cluster, Linear Cluster
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hunter User Manuals

Related Manuals