Uolfin 4978186 4-Light Matte Gold Contemporary Cage Chandelier Instruction Manual
- June 3, 2024
- Uolfin
Table of Contents
Uolfin 4978186 4-Light Matte Gold Contemporary Cage Chandelier
WARNING
(To reduce the risk of fire, electric shock, or injury to persons):
- We suggest installation by a licensed electrician.
- Please read the instruction carefully and save it as you may need it at later time.
- Before you start, NEVER attempt any work without shutting off the electricity until the work is done. A). Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position. B). Place the wall switch in the “OFF” position.
- Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all side. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
- Make sure that the ceiling or wall can stand the weight of the lamp before fixture.
- Make sure the voltage you are using is 120V. The maximum wattage is 25W per bulb.
- Keep the lamp away from acidic and basic objects in case of damaging the surface of the lamp.
- When replacing bulb, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
- The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:
TOOLS REQUIRED (NOT INCLUDED):
Before doing assembly and installation please prepare the needed tools as below picture
PARTS TYPE & QTY INCLUDING:
- (C) Single bar (1)
- (D) Green ground screw (1)
- (E) Canopy (1)
- (F) Collar ring (1)
- (G) Collar loop (1)
- (H) Quick link (2)
- (I) Chain (1)
- (J) Loop (1)
- (K) Stem (1)
- (L) Tube (1)
- (M) Iron ring (2)
- (N) Fixture loop assembly (1)
- (O) Crystal
- (P) Wire cage (14)
ACCESSORIES & QTY ENCLOSED:
- (A) Wire connector (3)
- (B) Mounting screw (2)
- (O) Crystal (2) spare parts
- (Q) Plastic loop (4)
ASSEMBLY & INSTALLATION INSTRUCTIONS:
- Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
- Make pre-installation
- Step A1: Slip tube (L) over the wires and then thread it into the top of fixture loop assembly (N). Screw all wire racks (P) on the fixture loop assembly (N).
- Step A2: Pass the stem (K) through the iron ring (M) and then tighten it with the tube (L). Adjust all the wires on the wire rack (P) to the correct position.
- Step A3: If any crystals fall off, Insert a plastic ring (Q) into the wire cage (P), then insert the crystal (O) and insert the plastic ring.
- Step B1: By measuring, determine the correct number of links needed for proper hanging height. Using the chain pliers, disconnect and discard the remaining chain.
- Step B2: Attach the quick link (H) to connect the chain (I) and the loop(J) on the the top of stem (K).
- Step B3: Carefully lace the wires through the chain (I)(every other link)and stop just before you reach the top of chain (I). Gently pull the wires till snug.
Turn off power
Before you start to make installation, NEVER attempt any work without shutting off the electricity until the work is done.
- Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
- Place the wall switch in the“OFF” position.
Make installation
-
Step C1: .Remove the collar ring (F) from collar loop(G). Attach the single bar (C) to outlet box with mounting screws (B).The side of single bar marked “GND” must face out, Unscrew the collar ring (F) from the collar loop.
-
Step C2: Raise the canopy (E) through screw collar loop (G) and screw the collar loop (G) to a proper position by measuring. Unscrew collar ring (F) from screw collar loop (G) and remove the canopy (E). In this way, you would know the Proper position on which collar loop it should be located.
Note: The canopy (E) should be snug against the ceiling and the collar loop (G) should be screwed enough threads (no less than 6 threads )over the threaded nipple for more secure hanging .If not, adjust the collar loop (G)on the single bar assembly by screwing the collar loop (G) in or out of the single bar (C) until the length is achieved. -
Step C3: Slip the collar ring(F) over the chain(I),then do the same with the canopy(E)
-
Step C4: Open the quick link(H),attach the quick link (H) to connect the loop (J). Close the quick link(H) Pass the wires through screw collar loop(G) to the top of nipple and gently pull till snug.
-
Step C5: If needed, cut off the wires length of fixture. At this point, the remaining wire length measured from the top of single bar(C) is at least 6″.
-
Step C6: Make wire connections
Connect wires as below wires connecting shown. TAKE NOTE OF YOUR COLOR OF FIXTURE ,NEVER CONNECT WIRES TO GROUND WIRES
Connect ground wire according to below chart Connect wires according to
below chart Twist plastic wire connector until wires are tightly joined
together, wrap each connector with approved electrical tape. Be sure that no
wire strands are exposed and then carefully tuck all wires into the outlet box
. Step C7: Raise canopy (E) to ceiling and secure canopy (E) in place by
tightening collar ring (F) onto collar loop (G). Step C8: Install the bulb
(not included) (Please do not exceed the maximum capacity recommended on the
socket.)
Check everything are already installed properly, then you could turn on the
light. Enjoy!
CLEANING.
To clean, wipe fixture with a soft cloth. Do not use abrasive materials such
as scouring pads or powders, steel wool or abrasive paper.
ORDERING PARTS.
Keep this sheet for future reference, and in case you need to order
replacement parts. All parts for this fixture can be ordered from place of
purchase. Be sure to use exact wording from illustration when ordering parts.