BRILLIAN BR-RW-0003 RFID Multifunction System
Brief introduction of equipment
Brillian Material Handling Solution(BMHS)
We provide a FAB semi-automatic material handling solution. Through a material
storage devices, integrating the BMHS system and database, product locations
and determine the transmission route, optimal throughput and increase
productivity.
eRack management collects all eRack status information, exchanges information
on behalf of all eRacks and MES. Provides admin search queries, work order
inquiries, statistical analysis, etc.
The eRack shelf can read the RFID tag on the foup by RFID antenna, transfer
the carrierID data to the background for unified management, and then receive
the foup information from the background to the operator.
Feature of Product
- The BMHS system centrally monitoring shelfs of E-Rack.
- Integrate MES and BMHS real time management systems to control all products in the factory.
- Significantly improve productivity.
- Flexible system’s configuration and higher utilization rate.
- Provide various statistical data to facilitate analysis and decision-making.
- RFID Reader helps to confirm whether the products and sites are correct before assisting production, which greatly reduce errors.
Description of safety rule of BR-RW-0003
Instruction for use
- This manual is only written for Purge System Module.
- Non-qualified or non-professional personnel are not allowed to operate or maintain the machine.
- “Operator” should read carefully the software operation in advance.
- “Maintainer”, in addition to getting familiar with software operation, should read carefully the maintenance manual and circuit diagram.
- Before careful reading of operation manual or before thorough understanding of machine function, it is not allowed to operate the machine singly, and it needs an experienced guy standing beside for instruction.
Instruction for transport
When transporting or moving a machine, it is suggested to use a cart for the
transport, please also wear steel shoes for personal safety. The cart should
be able to carry a load of more than 100Kg
For scarping of equipment or disposal of waste, please follow the local regulations
Instruction for illuminance in the work area: Please follow the lighting environment provided by the plant of the client send.
The machine is not suitable to work in explosive circumstances
Before ex-factory, the level of noise should be less than 80dB (A).
About “Warnings and Cautions”
Description of starting steps
Adapter to be AC 100~230V
Description of stopping steps
Please remove Adapter
Facility Requirement&SPEC
- Product Name RFID Multifunction System
- Model Type BRRW 000 3
- Rating Adapter
- I/P: 100~24 0VAC, 50/60Hz, 0.4A
- O/P: DC15V,1A
- Length X Width X Height(mm) 350X 100 X 345
- Weight kg
- Frequency 134.2KHz
FCC Rules
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:(1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation Warning: Changes or
modifications to this unit not expressly approved by the party responsible for
compliance could void the user authority to operate the equipment. This
Transmitter must not be colocated or operating in conjunction with any other
antenna or transmitter.
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user authority to operate
the equipment. This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
BR-RW-0003
Module | Illustration |
---|---|
Front-1 | ![BRILLIAN-BR-RW-0003-RFID-Multifunction- |
System-3](https://manuals.plus/wp-content/uploads/2022/12/BRILLIAN-BR-RW-0003 -RFID-Multifunction-System-3.png)
BR-RW-0003 Hardware
Hardware Method
Operation Description
Put a POD fixed on the goods which you need to get goods information. The Transponder has a data record for the good During the Host computer sent a order message to the CIDRW through RS232 or HSMS The CIDRW will sent back the goods information which read from the Transponder by radio frequency.
Periodical Maintenance
BR-RW0003 Maintenance Table
Machine Tool:| □ Three months| Date:| Operator:
Item| Maintenance Content| Cycle| Action| Result| Remark
Plate Clean
1| Clean Plate| Three months| Use DI Water &Cleanroom wiper Clean Plate| □OK
□NG|
2| Reader Test| Three months| Put the POD on Plate use button Check Reader
Function| □OK □NG|
Remark:|
Cleaning Plate
- Purpose: Cleaning Plate Particle
- Material: NA
- Manual tool: Cleanroom wiper、DI Water
- Notice: Before action, please confirm whether the machine is down
- PM Step: Cleanroom wiper cloth into the DI Water from inside to outside and from top to clean the Plate surface.
Manufacturer and publisher
Manufacturer and publisher
Brillian Network & Automation Integrated System Co.,Ltd
Add: No.41, Keyi St., Zhunan Township, Miaoli County 350, Taiwan, R.O.C.
Tel: 886-37-580708
Fax: 886-37-580728
Email services@brillian.com.tw
Website http://www.brillian.com.tw
The reproduction of any part of this user manual, in any from (by photocopying, microfilming or any other process) or the processing and distribution of the contents by electronic means is prohibited without the expressed written consent of Brillian. It is prohibited to copy the software or use it for other purposes. it is expressly prohibited to distribute copies of the software to third parties. Violators will be held liable for damage.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>