BRILLIAN STD AD100 Standalone N2 Purge System Instruction Manual

June 3, 2024
Brillian

Standalone N2 Purge System
Operation Manual Ver 1.0
Version STD AD100

The reproduction of any part of this user manual, in any from (by photocopying, microfilming or any other process) or the processing and distribution of the contents by  electronic means is prohibited without the expressed written consent of Brillian.
It is prohibited to copy the software or use it for other purposes. it is expressly prohibited to distribute copies of the software to third parties. Violators will be held liable for  damage.
Brillian Network & Automation Integrated System Co., Ltd.

Brief introduction of equipment

Brillian Material Handling Solution(BMHS)
We provide a FAB semi-automatic material handling solution. Through a material storage devices, integrating the BMHS system and database, product locations and  determine the transmission route, optimal throughput and increase productivity.
Rack management collects all eRack status information, exchanges information on behalf of all
Racks and MES. Provides admin search queries, work order inquiries, statistical analysis, etc.
The eRack shelf can read the RFID tag on the foup by RFID antenna, transfer the carrierID data to the background for unified management, and then receive the foup  information from the background to the operator.

Feature of Product

  • The BMHS system centrally monitoring shelfs of STD AD100.
  • Integrate MES and BMHS real time management systems to control all products in the factory.
  • Significantly improve productivity.
  • Flexible system’s configuration and higher utilization rate.
  • Provide various statistical data to facilitate analysis and decision-making.
  • RFID Reader helps to confirm whether the products and sites are correct before assisting production, which greatly reduce errors.

Description of safety rule of STD AD100

2.1 Instruction for use。
2.1.1 This manual is only written for Purge System Module。
2.1.2 Non-qualified or non-professional personnel are not allowed to operate or maintain the machine。
2.1.3 “Operator” should read carefully the software operation in advance。
2.1.4 “Maintainer”, in addition to getting familiar with software operation, should read carefully the maintenance manual and circuit diagram。
2.1.5 Before careful reading of operation manual or before thorough understanding of machine function, it is not allowed to operate the machine singly, and it needs an  experienced guy standing beside for instruction。
2.2 Instruction for transport
When transporting or moving a machine, it is suggested to use a cart for the transport, please also wear steel shoes for personal safety. The cart should be able to carry a load  of more than 100Kg
2.3 For scarping of equipment or disposal of waste, please follow the local regulations
2.4 Instruction for illuminance in the work area: Please follow the lighting environment provided by the plant of the client send.
2.5 The machine is not suitable to work in explosive circumstances
2.6 Before ex-factory, the level of noise should be less than 80dB (A).
2.7 About “Warnings and Cautions”BRILLIAN STD AD100 Standalone N2 Purge
System - figBRILLIAN STD AD100 Standalone N2
Purge System - fig 1

  1. When power is supplied, non-professional personnel should not operate it to avoid electric shock hazard.

  2. Before checking, maintenance and repair, please turn off the power.

  3. Description of starting steps
    3.1 Adapter to be AC 100~230V

  4. Description of stopping steps
    4.1 Please remove Adapter

  5. Facility Requirement&SPEC

Product Name Standalone N2 Purge System
Model Type STD AD100
Rating(Adapter) 100~230VAC, 50/60Hz, 1ɸ+PE
Length X Width X Height(mm)
Weight kg
Frequency 134.2KHz

FCC Rules

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this  device must accept any interference received, including interference that may cause undesired operation Warning: Changes or modifications to this unit not expressly  approved by the party responsible for compliance could void the user authority to operate the equipment.
This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful  interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

STD AD100

Module Illustration
![BRILLIAN STD AD100 Standalone N2 Purge System - fig

2](https://manuals.plus/wp-content/uploads/2022/11/BRILLIAN-STD- AD100-Standalone-N2-Purge-System-fig-2.png)

BRILLIAN STD AD100 Standalone N2 Purge System - fig 3

STD AD100 Hardware

8.1 Hardware MethodBRILLIAN STD AD100 Standalone N2 Purge System - fig
4

Operation Description

Put a FOUP fixed on the goods which you need to get goods information. The Transponder has a data record for the good During the Host computer sent a order message  to the CIDRW through RS232 or HSMS The CIDRW will sent back the goods information which read from the Transponder by radio frequency.

Periodical Maintenance

BRILLIAN STD AD100 Standalone N2 Purge System -
fig 5

10.1 Cleaning Plate
10.1.1 Purpose:Cleaning Plate Particle
Material:NA
Manual tool:Cleanroom wiper、DI Water
Notice:Before action, please confirm whether the machine is down
PM Step:Cleanroom wiper cloth into the DI Water from inside to outside and from top to clean the Plate surface.

BRILLIAN STD AD100 Standalone N2 Purge System - fig 6 Manufacturer and publisher
Brillian Network & Automation Integrated System Co.,Ltd
Add: No.41, Keyi St., Zhunan Township, Miaoli County 350,
Taiwan, R.O.C.
Tel: 886-37-580708
Fax: 886-37-580728
Email:[email protected]
Website: http://www.brillian.com.tw

Documents / Resources

| BRILLIAN STD AD100 Standalone N2 Purge System [pdf] Instruction Manual
STDAD100, 2A583-STDAD100, 2A583STDAD100, STD AD100 Standalone N2 Purge System, STD AD100, STD AD100 N2 Purge System, Standalone N2 Purge System, Standalone Purge System, N2 Purge System, Purge System
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Brillian User Manuals

Related Manuals