Midea MAP10S1CWT Portable Air Conditioner USER GUIDE

June 3, 2024
Midea

Midea MAP10S1CWT Portable Air Conditioner

Midea 10,000 BTU ASHRAE-PRODUCT

Safety Precautions

Read Safety Precautions Before Operation and Installation To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage.
WARNING

This symbol indicates the possibility of personnel injury or loss of life.

CAUTION
This symbol indicates the possibility of property damage or serious consequences.

WARNING

  • Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
  • Use only the included accessories and parts, and specified tools for the installation. Using nonstandard parts can cause water leakage, electrical shock, fire, and injury or property damage.
  • Make sure that the outlet you are using is grounded and has the appropriate voltage.
  • The power cord is equipped with a three-prong grounding plug to protect against shock.
  • Voltage information can be found on the nameplate of the unit.
  • Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse or circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on unit), have a qualified electrician install the proper receptacle.
  • Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
  • The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
  • Do not modify the length of the power cord or use an extension cord to power the unit.
  • Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
  • Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
  • Do not install the unit in a location that may be exposed to combustible gas, as this could cause fire.
  • The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could cause tipping.
  • Do not operate a unit that it has been dropped or damaged.
  • The appliance with electric heater shall have at least 1 meter space to the combustible materials.
  • Do not touch the unit with wet or damp hands or when barefoot.
  • If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
  • In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
  • Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can\ fall or be pulled into water or any other liquid. Unplug immediately if it occurs.
  • All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
  • The unit’s circuit board(PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.
  • When the water drainage function is not in use, keep the upper and the lower drain plug firmly to the unit to get rid of choking. When the drain plug is not in use, keep it carefully to prevent children from choking.

CAUTION

  • This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries)
  • This appliance is not intended for use by persons (including childern) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Children must be supervised around the unit at all times.(be applicable for other countries except the European Countries )
  • If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard.
  • Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
  • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
  • Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  • Do not operate unit with a damaged cord, plug, power fuse or circuit breaker. Discard unit or return to an authorized service facility for examination and/or repair.
  • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
  • The appliance shall be installed in accordance with national wiring regulations.
  • Contact the authorised service technician for repair or maintenance of this unit.
  • Contact the authorised installer for installation of this unit.
  • Do not cover or obstruct the inlet or outlet grilles.
  • Do not use this product for functions other than those described in this instruction manual.
  • Before cleaning, turn off the power and unplug the unit.
  • Disconnect the power if strange sounds, smell, or smoke comes from it.
  • Do not press the buttons on the control panel with anything other than your fingers.
  • Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
  • Do not operate or stop the unit by inserting or pulling out the power cord plug.
  • Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol,etc.
  • Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
  • Always contact a qualified person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
  • Hold the plug by the head of the power plug when taking it out.
  • Turn off the product when not in use.

Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)

  1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the CO2 equivalent in tonnes of the fluorinated greenhouse gas(on some models), please refer to the relevant label on the unit itself.
  2. Installation, service, maintenance and repair of this unit must be performed by a certified technician.
  3. Product uninstallation and recycling must be performed by a certified technician.

Sociable Remark

When using this dehumidifier in the European countries, the following information must be followed:

DISPOSAL

  1. Do not dispose this product as unsorted municipal waste.
  2. Collection of such waste separately for special treatment is necessary.
  3. It is prohibited to dispose of this appliance in domestic household waste.
  4. For disposal, there are several possibilities
  • The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • When buying a new product, the retailer will take back the old product at least free of charge.
  • The manufacture will take back the old appliance for disposal at least free of charge to the user.
  • As old products contain valuable resources, they can be sold to scrap metal dealers. Wild disposal of waste in forests and landscapes endangers your health when hazar do us substances leak into the ground-water and find their way into the food chain.

WARNING for Using R32/R290 Refrigerant

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that the refrigerants may not contain an odour.
  • Appliance should be installed, operated and stored in a room with a floor area according to the amount of refrigerant to be charged. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the lable and the manual on the Min. room area description, the description on label shall prevail.

For R290

| amount of refrigerant (kg)| Min. room area(m²)| amount of refrigerant (kg)| Min. room area(m²)|
---|---|---|---|---|---
0.0836 and| 0.1045| 4| 0.2090 and| 0.2299| 11
0.1045 and| 0.1254| 4| 0.2299 and| 0.2508| 12
0.1254 and| 0.1520| 4| 0.2508 and| 0.2717| 13
0.1520 and| 0.1672| 8| 0.2717 and| 0.2926| 14
0.1672 and| 0.1881| 9| 0.2926 and| 0.3040| 15
| | | | |
0.1881 and| 0.2090| 10| |

  • Compliance with national gas regulations shall be observed.
  • Keep ventilation openings clear of obstruction.
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry-recognised assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervisionof the person competent in the use of flammable refrigerants.
  • Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, shall not discharge to air directly.
  • No any open fire or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used.
  • Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
  • Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.For speci-c information on the type of gas and the amount,please to the relevant label on the unit itself.

Caution: Risk of fire/ flammable materials (Required for R32/R290 units only)

Explanation of symbols displayed on the unit(For the unit adopts R32/R290 Refrigerant only):
WARNING
This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
Caution:

  • This symbol shows that the operation manual should be read carefully.
  • This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
  • This symbol shows that information is available such as the operating manual or installation manual.
  1. Transport of equipment containing flammable refrigerants
    See transport regulations

  2. Marking of equipment using signs
    See local regulations

  3. Disposal of equipment using flammable refrigerants
    See national regulations.

  4. Storage of equipment/appliances
    The storage of equipment should be in accordance with the manufacturer’s instructions.

  5. .Storage of packed (unsold) equipment
    Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.

  6. Information on servicing

    • Checks to the area
      Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

    • Work procedure
      Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed

    • General work area
      All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

    • Checking for presence of refrigerant
      The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.

    • Presence of fire extinguisher
      If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

    • No ignition sources
      No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.

    • Ventilated area
      Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
      Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
      Initial safety checks shall include:
      That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
      That there no live electrical components and wiring are exposed while charging, recovering or purging the system; That there is continuity of earth bonding.

    • Checks to the refrigeration equipment
      Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
      The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
      The ventilation machinery and outlets are operating adequately and are not obstructed;
      If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
      Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

    • Checks to electrical devices
      Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
      Initial safety checks shall include:
      That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; That there no live electrical components and wiring are exposed while charging, recovering or purging the system; That there is continuity of earth bonding.

  7. Repairs to sealed components

    • During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
    • Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
      NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
  8. Repair to intrinsically safe components
    Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

  9. Cabling
    Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

  10. Detection of flammable refrigerants
    Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  11. Leak detection methods
    The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

  12. Removal and evacuation
    When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to:
    Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing.
    The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.

  13. Charging procedures
    In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them.
    Cylinders shall be kept upright.
    Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.

  14. Decommissioning
    Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.

    • Become familiar with the equipment and its operation.
    • Isolate system electrically.
    • Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders; All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.
    • Pump down the refrigerant system, if possible.
    • If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
    • Make sure that the cylinder is situated on the scales before recovery takes place.
    • Start the recovery machine and operate in accordance with the manufacturer’s instructions.
    • Do not overfill cylinders. (No more than 80 % volume liquid charge).
    • Do not exceed the maximum working pressure of the cylinder, even temporarily.
    • When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
    • Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
  15. Labeling
    Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

  16. Recovery
    When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
    In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
    Consult the manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

Installation Instructions

Preparation
The unit can be controlled by the unit control panel alone or with the remote controller. This manual does not include Remote Controller Operations, see the <> packed with the unit for details.Midea
10,000 BTU ASHRAE-1

Design Notice

In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice.

Ambient Temperature Range For Unit Operating

MODE Temperature Range MODE Temperature Range

Cool

| ****

17-35°C (62-95°F)

| Heat(pump heat mode)| ****

5-30°C (41-86°F)


Dry

| ****

13-35°C (55-95°F)

| Heat(electrical heat mode)| ****

30°C (86°F)

Exhaust hose installation
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. For COOL,HEAT(heat pump type) or AUTO mode must be installed exhaust hose. For FAN, DRY or HEAT (electrical heat type) mode must be removed exhaust hose.

Choosing The Right Location
Your installation location should meet the following requirements:

  • Make sure that you install your unit on an even surface to minimize noise and vibration.
  • the unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
  • The unit should be located at least 30cm (12”) from the nearest wall to ensure proper air conditioning. The horizontal louver blade should be at least 50cm (19.7”) away from obstacles.
  • dO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.

Recommend Installation

Energy Rating Information

The energy rating and noise information for this unit is based on the standard installation using an un-extended exhaust duct (Diameter:150mm, Length:1.5m) without window slider ada ptor or wall exhaust adaptor A.
The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts(Diameter:150mm, Length:1.5m + Diameter: 130mm, Length: 1.5m) .The Energy rating and noise information for unit with 3 meters extended exhaust duct is not assessed.(For some models)
NOTE:
We recommend that operating the unit at room temperature below 35°C . Since there is a risk that the unit with 3 meters extended exhaust duct would not work at room temperature above 35°C under some extreme conditions, such as the lower air intake be blocked for 50%.

How to Stay Cool with a New Portable Air Conditioner(For the models comply with the requirements of the Department Of Energy in US)

Because of a new federal test procedure for Portable Air Conditioners, you may notice that the cooling capacity claims on portable air conditioner packaging are significantly lower than that of models produced prior to 2017. This is due to changes in the test procedure, not to the portable air conditioners themselves.

What should I look for first when purchasing a portable air conditioner?
The right air conditioner helps you cool a room efficiently. An undersized unit won’t cool adequately while one that’s too large will not remove enough humidity, leaving the air feeling damp. To find the proper air conditioner, determine the square footage of the room you want to cool by multiplying the room length by its width. You also need to know the air conditioner’s BTU (British Thermal Unit) rating, which indicates the amount of heat it can remove from a room. A higher number means more cooling power for a larger room. (Be sure you are comparing only newer models to each other- older models may appear to have a higher capacity, but are actually the same). Be sure to “size up” if your portable air conditioner will be placed in a very sunny room, in a kitchen, or in a room with high ceilings. After you’ve found the right cooling capacity or your room, you can look at other features.
Why is the cooling capacity lower on newer models than on older units?
Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure, which was changed just this year. Models manufactured before 2017 were tested under a different procedure and cooling capacity is measured differently than in prior years’models. So, while the BTUs may be lower, the actual cooling capacity of the air conditioners has not changed.
What is SACC?
SACC is the representative value of Seasonally Adjusted Cooling Capacity, in Btu/h, as determined in accordance with the DOE test procedure at title 10 Code of Federal Regulations (CFR) 430, subpart B, appendix CC and applicable sampling plans.

Tools Needed

  • Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors;
  • saw (On some models, to shorten window adaptor for narrow windows)

Accessories

NOTE: Items with (*) are on some models. Slight variations in design may occur.

North America Other RegionsMidea 10,000 BTU
ASHRAE-5

w indow Installation Kit

Type window installation: Type wall installation:


  1. Step One: Preparing the Exhaust Hose assembly
    Press the exhaust hose(or extended exhaust hose) into the window slider adaptor(or wall exhaust adaptor) and unit adaptor, clamp automatically by elastic buckles of the adaptors.

  2. Step Two: Install the Exhaust hose assembly to the unit
    Insert unit adaptor of the Exhaust hose assembly into the lower groove of the air outlet of the unit while the hook of the adaptor is aligned with the hole seat of the air outlet and slide down the Exhaust hose assembly along the arrow direction for installation.

  3. Step Three: Preparing the Adjustable Window Slider

    • Choose the window sliders according to the size of your window. Sometimes, it needs to be cut short to meet the window size, please take extra care to cut it properly.
    • Use bolts to fasten the window sliders once they are adjusted to the Proper length.Midea 10,000 BTU ASHRAE-10 Midea 10,000 BTU ASHRAE-11

Installation

NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods.

Type 1: Hung Window or Sliding Window Installation(For some models)

  1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.
  2. Insert the window slider assembly into the window opening.
  3. Cut the non-adhesive foam seal C strip to match the width(or height) of the window. Insert the seal between the glass and the window frame to prevent air and insects from getting into the room.Midea 10,000 BTU ASHRAE-14
  4. If desired, install the security bracket with 2 screws as shown.
  5. Insert the window slider adaptor into the hole of the window slider.Midea 10,000 BTU ASHRAE-16

Type 2: Wall Installation(For some models)

  1. Cut a 125mm (4.9inch) hole into the wall for the Wall Exhaust Adaptor B.
  2. Secure the Wall Exhaust Adaptor B to the wall using the four Anchors and Screws provided in the kit.
  3. Connect the Exhaust Hose Assembly(with Wall Exhaust Adaptor A) to the Wall Exhaust Adaptor B.Midea 10,000 BTU ASHRAE-17
    NOTE: To ensure proper function, DO NOT overextend or bend the hose. Make sure that there is no obstacle around the air outlet of the exhaust hose (in the range of 500mm) in order to the exhaust system works properly. All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail.

Operating Instructions

Control Panel Features

NOTE: The following control panels are for explanation purposes only. The control panel of the unit you purchased may be slightly different according to the models. Your machine may not contain some indicators or buttons. The actual shape shall prevail.Midea 10,000 BTU ASHRAE-19

  • Wireless button(On some models)
    Used to initiate the wireless connection mode. For the first time to use the wireless function, press the wireless button for 3 seconds to initiate the wireless connection mode. The LED DISPLAY shows ‘AP’ to indicate you can set a wireless connection. If the connection(router) is successful within 8 minutes, the unit will exit wireless connection mode automatically and the wireless indicator illuminates.
    If the connection is a failure within 8 minutes, the unit exits wireless connection mode automatically. After Wireless connection is successful, for some models you can press Wireless and DOWN (-) buttons at the same time for 0.5 seconds to turn off the Wireless function and the LED DISPLAY shows ‘OF’ for 3 seconds, press Wireless button to turn on the Wireless function and the LED DISPLAY shows ‘ON’ for 3 seconds.
    NOTE: When you restart the wireless function, it may take a period of time to connect to the network automatically.

  • Swing button(On some models)
    (Applicable to the models with auto swing feature only)
    Used to initiate the Auto swing feature. When the operation is ON, press the SWING button can stop the louver at the desired angle.

  • Sleep(Eco)/Filter button
    Used to initiate the SLEEP/ECO operation.
    NOTE: After 250 hours of operation, the filter indicator light illuminates. This feature is a reminder to clean the Air Filter for more efficient operation. Press this button for 3 seconds to cancel the reminder.

  • Timer button Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjuction with the + & – buttons. The timer on/off indicator light illuminates under the timer on/off settings.

  • Fan/Constant fan(On some models) button Control the fan speed. Press to select the fan speed in four steps-LOW, MID(MED), HIGH and AUTO. The fan speed indicator light illuminates under different fan settings.
    NOTE: In cooling or Dry mode, press the button for 3 seconds to turn on or off the constant fan function. When the function is turned on, the constant fan light will illuminate, identifying the fan continuous run for cooling. When the function is turned off, the constant fan light will go out, identifying the fan cycle run with compressor stop.

  • On some models Ion light is instead of constant fan light.
    Press the button for 3 seconds, the Ionizer is energized and will help to remove pollen and impurities from the air.

  • Mode button
    Selects the appropriate operating mode. Each time you press the button, a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN and HEAT (cooling only models without). The mode indicator light illuminates under the different mode settings.

  • Up (+) and Down (-) buttons
    Used to adjust (increasing/decreasing) temperature settings in 1°C/1°F (or 2°F) increments in a range of 17°C/62°F to 30°C/86°F (or 88°F) or the TIMER setting in a range of 0~ 24hrs.
    NOTE: The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.

  • Power button
    Power switch on/off.

  • LED display
    Shows the set temperature in °C or °F and the Auto-timer settings. While on DRY and FAN modes, it shows the room temperature. Shows Error codes and protection code:

    • E1-Room temperature sensor error.
    • E2-Evaporator temperature sensor error.
    • E3-Condenser temperature sensor error (on some models).
    • E4-Display panel communication error.
    • EC-Refrigerant leakage detection malfunction(on some models).
    • E7-Zero-crossing malfunction.
    • The P1-Bottom tray is full–Connect the drain hose and drain the collected water away.If protection repeats, call for service.

Note: When one of the above malfunctions occurs, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact the manufacturer or its service agents or a similar qualified person for service.

Operation Instructions

COOL operation

  • Press the “MODE” button until the “COOL” indicator light comes on.

  • Press the ADJUST buttons “+” or “-” to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~88°F(or 86°F).

  • Press the “FAN SPEED” button to choose the fanspeed.
    HEAT operation(cooling only models without)

  • Press the “MODE” button until the “HEAT” indicator light comes on.

  • Press the ADJUST buttons “+” or ” – ” to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~88°F (or 86°F).

  • Press the “FAN SPEED” button to choose the fan speed.
    Note: For some models, the fan speed can not be adjusted under HEAT mode. DRY operation

  • Press the “MODE” button until the “DRY” indicator light comes on.

  • Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor operates at LOW speed.

  • Keep windows and doors closed for the best dehumidifying effect.

  • Do not put the duct to the window.

AUTO operation

  • When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature.

  • The air conditioner will control room temperature
    automatically round the temperature point set by you.

  • Under AUTO mode, you can not select the fan speed.
    NOTE: Under AUTO mode, both the AUTO mode and the actual operation mode indicator lights illuminate for some models.

FAN operation

  • Press the “MODE” button until the”FAN ” indicator light comes on.
  • Press the “FAN SPEED” button to choose the fan speed. The temperature can not be adjusted.
  • Do not put the duct to the window.

TIMER operation

  • When the unit is on, press the Timer button will initiate the Auto-off stop program, the TIMER OFF indicator light illuminates. Press the UP or down button to select the desired time. Press the TIMER button again within 5 seconds, the Auto-on start program is initiated. And the TIMER ON indicator light illuminates. Press the up or down button to
    select the desired Auto-on start time.

  • When the unit is off, press the Timer button to initiate the Auto-on start program, press it again within five seconds will initiate the Auto-off stop program.

  • Press or hold the UP or DOWN button to change the Auto time by 0.5-hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until the start.

  • The system will automatically revert back to display the previous temperature setting if there is no operation in a 5 seconds period.

  • Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timer program.

  • When the malfunction occurs, the Auto Start/Stop timed program will also be canceled.

SLEEP/ECO operation

  • Press this button, the selected temperature will increase(cooling) or decrease(heating) by 1°C/2°F(or 1°F) 30 minutes.The temperature will then increase (cooling) or decrease (heating) by another 1°C/2°F(or 1°F) after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the Sleep/Eco mode and the unit will continue to operate as originally programmed.
    NOTE: This feature is unavailabe under FAN or DRY mode.

Other features

FOLLOW ME/TEMP SENSING feature(On some models)
NOTE: This feature can be activated from the remote control ONLY. The remote control serves as a remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me/Temp Sensing feature, point the remote control towards the unit and press the Follow Me/Temp Sensing button. The remote control will send this signal to the air conditioner until press the Follow Me/Temp Sensing button again. If the unit does not receive the Follow Me/Temp Sensing signal during any 7 minutes interval, the unit will exit the Follow Me/Temp Sensing mode.
NOTE: This feature is unavailabe under FAN or DRY mode.
AUTO-RESTART
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING THE OPERATION
After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.

AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the air flow direction automatically 🙁 NOTE: On some models the louver can be adjusted manually only)

  • When the Power is ON, the louver opens fully.
  • Press the SWING button on the panel or remote controller to initiate the Auto swing feature. The louver will swing up and down automatically.
  • Please do not adjust the louver manually.

POWER MANAGEMENT feature(On some models)
Under cooling operation, when the ambient temperature is lower than the setting temperature for a period of time, the unit will automatically operate power management feature. The compressor and fan motor stop. When the ambient temperature is higher than the setting temperature, the unit will be automatically quit the power management feature. The compressor and (or) fan motor run.

Water drainage

  • During dehumidifying modes, remove the upper drain plug from the back of the unit, and install the drain connector(5/8″ universal female mender) with 3/4″ hose(locally purchased). For the models without drain connectors, just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your basement floor.

  • During heating pump mode, remove the lower drain plug from the back of the unit, install the drain connector(5/8″universal female mender) with 3/4″ hose(locally purchased). For the models without a drain connector, just attach the drain hose to the hole. Place the open end of the Hose adaptor directly over the drain area in your basement floor.
    NOTE: Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure that there are no kinks that will stop the warter flowing. Place the end of the hose into he drain and make sure the end of the hose is down to let the water flow smoothly. (See Figs with. Do never let it up.(See Figs with ).When the continuous drain hose is not used, ensure that the corresponding drain plug and knob are installed firmly to prevent leakage.Midea 10,000 BTU ASHRAE-22

  • When the water level of the bottom tray reaches a predetermined level, the unit beeps 8 times, the digital display area shows “P1” . At this time the air conditioning/dehumidification process will immediately stop. However, the fan motor will continue to operate(this is normal). Carefully move the unit to a drain location, remove the bottom drain plug and let the water drain away. Reinstall the bottom drain plug and restart the machine until the “P1” symbol disappears. If the error repeats, call for service.
    NOTE: Be sure to reinstall the bottom drain plug firmly to prevent leakage before using the unit.

Maintenance

Safety Precautions

  • Always unplug the unit before cleaning or servicing.
  • DO NOT use flammable liquids or chemicals to clean the unit.
  • DO NOT wash the unit under running water. Doing so causes electrical danger.
  • DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.

Air Filter Cleaning

CAUTION
DO NOT operate the unit without a filter because dirt and lint will clog it and reduce performance.

Maintenance Tips

  • Be sure to clean the air filter every 2 weeks for optimal performance.
  • The water collection tray should be drained immediately after the P1 error occurs, and before storage to prevent mold.
  • In households with animals, you will have to periodically wipe down the grill to prevent blocked airflow due to animal hair.

Unit Cleaning

Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth.

Store the unit when not in use

  • Drain the uni t’s water collection tray according to the instructions in the following section.
  • Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold.
  • Turn off the appliance and unplug it.
  • Clean the air filter according to the instructions in the previous section. Reinstall the clean, dry filter before storing.
  • Remove the batteries from the remote control.

NOTE: Be sure to store the unit in a cool, dark place. Exposure to direct sunshine or extreme heat can shorten the lifespan of the unit.
NOTE: The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mildliquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleansers, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the unit.

Troubleshooting Tips

Problem Possible Causes Solution

Unit does not turn on when pressing ON/OFF button

|

P1 Error Code

| The Water Collection Tray is full. Turn off the unit, drain the water from the Water Collection Tray and restart the unit.
In COOL mode: room temperature is lower than the set temperature|

Reset the temperature

Unit does not cool well

| The air filter is blocked with dust or animal hair| Turn off the unit and clean the filter according to instructions
Exhaust hose is not connected or is blocked| Turn off the unit, disconnect the hose, check for blockage and reconnect the hose
The unit is low on refrigerant| Call a service technician to inspect the unit and top off refrigerant
Temperature setting is too high| Decrease the set temperature
The windows and doors in the room are open| Make sure all windows and doors are closed
The room area is too large| Double-check the cooling area
There are heat sources inside the room| Remove the heat sources if possible
The unit is noisy and vibrates too much| The ground is not level| Place the unit on a flat, level surface
The air filter is blocked with dust or animal hair| Turn off the unit and clean the filter according to instructions
The unit makes a gurgling sound| This sound is caused by the flow of refrigerant inside the unit|

This is normal

Impedance Information

To be in compliance EN 61000-3-11, the product MPPFB-12CRN1-QC1 shall be connected only to a supply of the system impedance: | Zsys|=0.452 ohms or less, the product MPPFB-12CRN7-QB6 shall be connected only to a supply of the system impedance: | Zsys|=0.371 ohms or less. Before connect the product to public power network, please consult your local power supply authority to ensure the power network meets above requirement.
The model MPPFB-11CRN7-QB6 should be connected only to a supply with the relevant system impedance no more than 0.373 ohm. Restrictions to connection may be imposed by the supply authority on the use of equipment in the actual relevant system impedance at the interface point on the user’s premise exceeds 0. 373 ohm.
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.

FAQS

Is this unit bucketless?

Yes, it uses a drain hose and not a bucket. Have an excellent day! MideaCustomerCare@hartehanks.com (BBB A+ Accredited Business)

Are these media air conditioner reliable?

Yes, our units are very reliable. You can take a look further into Midea at midea.com. Hope this helps. Have a fantastic day! MideaCustomerCare@hartehanks.com (BBB A+ Accredited Business)

Window installation

This unit’s installation procedures start on page 13 of the user’s manual attached: https://m.media-amazon.com/images/I/B1z6ZDDn33S.pdf Have a fantastic day! MideaCustomerCare@hartehanks.com (BBB A+ Accredited Business)

Can it be used in a garage?

If your garage has a window or some sort of opening for the dual hose, yes. It can be used. If not, no. For the AC to cool air inside, it needs to pull outside air and expel exhaust through its dual hose. So, without the hose being able to take in outside air and take out exhaust, it is useless.

Does this model work on a 15 amp circuit

The label on the right side of the unit says 11.9 Amps (9 Amps may be for the 12K model). Mine seems to be running fine on a 15A circuit.

How long is the duo hose? Need a good length for basement window installment.

The hose will extend from the top of the unit to a height of about 7.5 to 8 ft. The hose practical length is shorter as it must turn to face the wall. It could probably vent out a wall at about 6 foot height. The hose itself is about 5 feet long.

What is the efficiency rating?

Yes, our units are very reliable. This unit runs 115v and 60Hz, 9 amps, and 1035Watts. Efficiency rating is the BTU Divided by Watts so that shows the Efficiency rating at 13.52. Have a fantastic day! MideaCustomerCare@hartehanks.com (BBB A+ Accredited Business)

Is it really a 12,000 btu sacc-rated unit? I cannot find the specifications on the midea USA website.

The two ratings for this unit reflect two measurements of energy efficiency. 14,000 BTU is the ASHRAE cooling rating. 12,000 BTU is the DOE cooling rating. Have an excellent day! MideaCustomerCare@hartehanks.com (BBB A+ Accredited Business)

Does this unit come in white?

This unit does not come in white. Have an excellent day! MideaCustomerCare@hartehanks.com

Does it heat?

No, this model does not offer heat. Have an excellent day! MideaCustomerCare@hartehanks.com (BBB A+ Accredited Business)

Is this a self-evaporating a.c?

This unit uses Midea’s industry-first hose-in-hose design enables the unit to intake and exhaust air outdoors, so it can form a balanced air circulation indoors, effectively preventing hot air from seeping into the room through gaps around doors and windows.

Why can’t this product ship to my house in Wa state?

I was able to have one shipped to Washington State. The order was placed on 7/6/21. Hopefully, this issue has been resolved.

What is the maximum window width that the included adjustable panels will fit?

The dimensions are based on the size of the hose. This unit can be installed in vertical, horizontal, and sliding windows. Please review the hose width and specs in the installation instructions provided. https://m.media- amazon.com/images/I/B1z6ZDDn33S.

did anyone install this in an RV?

Yes, this unit can be installed in an RV as long as the space provided by the window is sufficient. This unit’s installation procedures start on page 13 of the user’s manual attached: https://m.media- amazon.com/images/I/B1z6ZDDn33S.pdf Have a fantastic day! MideaCustomerCare@hartehanks.com (BBB A+ Accredited Business)

VIDEO

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>