PHOTOBIO CX 2125 Compact High Performance LED Fixture User Manual

June 3, 2024
PHOTOBIO

PHOTOBIO logo

PHANTOM
USER MANUAL
PHOTOBIO•CX 2125
PHOTOBIO CX 2125 Compact High Performance LED Fixture -
fig 10

OVERVIEW

PHOTOBIO CX 2125 120–277V S4 LED

  • 2125 μmol/s Photon Flux @277V
  • 2.5 μmol/J Efficacy @277V
  • 1:1 replacement for 1000W HPS utilizing similar footprint
  • Includes manual dimming and an on-board digital screen for monitoring output levels
  • Compatible with PX Controllers for dimming – 500 pieces per zone
  • Passive heat cooling fins
  • Voltage: 120–277V
  • 5 year warranty
  • IP66 rated for water and dust protection

SPECTRA

ELECTRICAL SPECIFICATION

Item Code| Model| Spectrum| Application| Photon
Flux (µmol/s)| Power
(W)| Efficacy
(µmol/J)| Dimming| IP| Weight| Voltage| Lifetime
to L90
---|---|---|---|---|---|---|---|---|---|---|---
PTB8850LS4X| PHOTOBIO·CX 2125| S4| Vegetative
& Flowering| 2125| 850| 2.5| 0–10V| IP66| 27.55 lbs/
12.50kg| 120–277V| ≥50,000 hr

PRODUCT DIMENSIONS

PHOTOBIO CX 2125 Compact High Performance LED Fixture - fig
10

PARTS LIST

PHOTOBIO CX 2125 Compact High Performance LED Fixture - fig
0

A: PHOTOBIO·CX 2125 fixture
B: 10′ 0–10V Control Cable
C: Eye hook (x5)
D: C hangers (x2)
E: Instructions

  • Avoid direct eye exposure to the light source while it is on.
  • Account for small parts and recycle or dispose of packing material properly.

CABLE HARNESSES & ACCESSORIES (SOLD SEPARATELY)
CABLE HARNESSES

Power cable harness sold separately based upon your specific requirements.

| TYPE OF MALE| ITEM CODE| DESCRIPTION
---|---|---|---
| CHE1063000W| 10′ F 16AWG WT w/leads, Harness
| CHE1063010W| 10′ F 16AWG WT 110–120V Plug, 5-15P, Harness
| CHE1063015W| 10′ F 16AWG WT 208–240V Plug, 6-15P, Harness
| CHE1083020W| 10′ F 18AWG WT locking 277V, L7-15P, Harness
| CHE1083021W| 10′ F 18AWG WT locking 277V, L7-20P, Harness

AUTOPILOT PX2 ADVANCED LIGHTING CONTROLLER
Centralized control of up to 1000 PHOTOBIO fixtures. Provides dual zone photoperiod timing, photosynthetic photon flux scheduling, temperature based auto-dimming, high temp shutdown, sunrise/sunset simulation, with built in battery backup.
Important: The PHOTOBIO CX needs to use a specific version of the Autopilot PX2 to work properly. V2.01 is not compatible. V2.02 is compatible with S/N 29702052, 29702128, 29702126 and 29702116. V2.03 and higher are compatible. For technical questions please reach out to support@hydrofarm.com.

PHOTOBIO CX 2125 Compact High Performance LED Fixture - fig
6| ITEM CODE| DESCRIPTION
---|---|---
APDPX2| Autopilot PX2 Advanced Lighting Controller

DATA LINK CABLE SOLD SEPARATELY TO CONNECT CX 2125 FIXTURE TO AUTOPILOT PX2 CONTROLLER

| ITEM CODE| DESCRIPTION
---|---|---
CHC223108W| 20′ Mini 3P(M) to Mini 3P(F) WT data link cable

WARNING – POSSIBLE RISK OF INJURY TO EYES AND SKIN
Hazardous optical UV, HEV, and IR radiation may be emitted from the light source. Always wear personal protective equipment ensuring complete shielding of skin and eyes. Avoid prolonged exposure and looking directly at light source.
WARNINGS
Please read these installation instruction carefully and keep it on hand. Before installing, servicing,  or performing routine maintenance, follow these general precautions:

  • For the installation: if you are unsure about the installation or maintenance of this fixture, consult a qualified licensed electrician and check your local electrical code.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Turn off the power and unplug fixture when you perform any maintenance or cleaning activity.
  • Verify that supply voltage is correct by comparing it with the information on spec label.
  • Avoid hitting, bending or causing mechanical stress to the fixture.
  • DO NOT cover or block any part of the fixture during operation.
  • To ensure optimal performance, the area between the fins of the heatsink may require periodic cleaning. Clean with compressed air or damp lint free cloth.
  • 12″ Clearance must be maintained from any combustible surface.
  • Always provide a well-ventilated environment where ambient temperatures do not exceed 40°C (104°F) regardless of whether the fixtures are in operation or off. Excessive temperatures  can inhibit performance and may cause damage or shorten the life of the fixtures and void the warranty.
  • Do not run or store fixtures in the facility unless proper environmental cooling systems are in operation. Facilities that are “shut down” can record excessively high temperatures resulting in premature equipment failure.
  • When calculating cooling needs for your facility, take into consideration BTU load generated by LED fixtures and latent load generated by plant transpiration, human respiration, etc…
  • This IP 66 LED fixture is intended for indoor and greenhouse use only. Avoid high pressure jets of water.
  • Do not expose the fixture to the sulfur dioxide compound. If sulfur application is part of your practice, please make sure to remove the fixtures prior to this process.

ADDITIONAL SAFETY WARNINGS:

  • Cables shall not be concealed or extended through a wall, floor, ceiling, or other parts of the building structure.
  • Cables shall not be located above a suspended ceiling or dropped ceiling; permanently affixed to the building structure.
  • Cables shall be routed so that they are not subject to strain and are protected from physical damage; and visible over their entire length.
  • Cables shall be used within their rated ampacity as determined for the maximum temperature of the installed environment specified in the instructions.
  • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  •  ICES-005

INSTALLATION

Be sure that the fixture is unplugged from the power source before installation.
Make sure to leave a top clearance of 6 inch and side clearance of 2 inch.

MOUNTING

SUSPENDED MOUNTING WITH FIXTURE HANGER A (EYEBOLTS ARE INCLUDED WITH THE FIXTURE)
Install the eyebolts into the holes.PHOTOBIO CX 2125 Compact High
Performance LED Fixture - fig 12

MOUNTING
SUSPENDED MOUNTING WITH FIXTURE HANGER B (SLING HANGER IS NOT INCLUDED WITH THE FIXTURE)
Attach the clip ends of the sling hangers into the mounting holes.PHOTOBIO
CX 2125 Compact High Performance LED Fixture - fig 14

MOUNTING
STRUT MOUNTING WITH FIXTURE HANGER C

  1. Install the C hangers into the M6 holes with M6 bolts. Be sure the direction of the two C hangers matches the direction in the illustration below.PHOTOBIO CX 2125 Compact High Performance LED Fixture - fig 15
  2. Mount the C hangers on the truss.PHOTOBIO CX 2125 Compact High Performance LED Fixture - fig 16

POWER CONNECTION

Connect the power cord with the driver AC connector.PHOTOBIO CX 2125 Compact
High Performance LED Fixture - fig 17

DIMMING CONNECTION (OPTIONAL)
The product is equipped with dimming connection supporting 0–10V dimming signal. Purchase a 20′ Mini 3P(M) to Mini 3P(F) WT data link cable (Item Code: CHC223108W) to interface with Autopilot PX2 advanced digital & analog lighting controller (APDPX2) to centralize control of up to 1,000 PHOTOBIO fixtures. For connections between aisle to aisle, please use provided 10′ 0–10V Control Cable.

TROUBLESHOOTING

PROTECTION DESCRIPTION ERROR CODE
Input High Voltage Protection happens when input voltage exceeds 320V.

Fixture will try to ignite as per ignition interval 1-5-5-5-5, and then shut off if input voltage is still high. If the input voltage returns to normal during ignition interval, the fixture will return to normal operation.| E1
Input Low Voltage| Protection happens when input voltage is lower than 105V. Output power will be dropped to 80%. When input voltage is lower than 96V, fixture will try to ignite as per ignition interval 1-5-5-5-5, and then shut off if input voltage is still low. If the input voltage returns to normal during ignition interval, the fixture
will return to normal operation.| E2
High Temperature| Protection happens when inter temperature is higher than 90°C. The output power will be dropped to 80%. Fixture will be shut off when inter temperature is higher than 100°C. When inter temperature is lower than 80°C, fixture will return to normal operation.| E3
Output Abnormal| LED chips are not working normally.| E4

TECHNICAL SUPPORT

For technical support, please contact Support@Hydrofarm.com.

IMPORTANT: The PHOTOBIO CX needs to use a specific version of the Autopilot PX2 to work properly. V2.01 is not compatible. V2.02 is compatible with S/N 29702052, 29702128, 29702126 and 29702116*****. V2.03 and higher are compatible. For technical questions please reach out to support@hydrofarm.com.

PHOTOBIO CX 2125 Compact High Performance LED Fixture - fig
20PHOTOBIO CX 2125 Compact High
Performance LED Fixture - fig 21

IMPORTANT: Do not attach data link cables to AC power cable. Always keep low voltage data cables and high voltage AC power harness as far as possible from each other for stable signal transmission. Avoid coiling data cables as well as AC harnesses in tight coils. Excess cable should be managed by creating long loops as opposed to tight coils.

LIMITED WARRANTY

Hydrofarm warrants PHOTOBIO•CX to be free from defects in materials and workmanship. The warranty term is for 5 years beginning on the date of purchase. Misuse, abuse, or failure to follow instructions is not covered under this warranty. Hydrofarm warranty liability extends only to the replacement cost of the product. Hydrofarm will not be liable for any consequential, indirect, or incidental damages of any kind, including lost revenues, lost profits, or other losses in connection with the product. Some states do not allow limitation on how long an implied warranty lasts or the exclusion of incidental or consequential damages, so the above limitations or exclusions may not
apply to you. Hydrofarm will, at our discretion, repair or replace PHOTOBIO•CX covered under this warranty if it is returned to the original place of purchase. To request warranty service, please return PHOTOBIO•CX, with original sales receipt and original packaging to your place of purchase. The purchase date is based on your original sales
receipt.

https://hydrofarm.com/

Thank you for choosing PHOTOBIO by Hydrofarm. For further information about PHOTOBIO products, videos and technical information, please visit
Hydrofarm.com or PhantomBio.com.

Get Connected with the Hydrofarm Community: Like us on Facebook, follow us on Twitter, and check out Hydrofarmtv and PhotobioLED on YouTube and Instagram!
PTB8850LS4X_instructions_Feb2022
Revised February 21, 2022 7:26 pm
www.phantombio.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals