PHOTOBIO CX 2125 100-277V S4 Compact High Performance LED Fixture User Manual

October 28, 2023
PHOTOBIO

PHOTOBIO CX 2125 100-277V S4 Compact High Performance LED Fixture

OVERVIEW

PHOTOBIO•CX 2125 120–277V S4 LED

  • 2125 μmol/s Photon Flux @277V
  • 2.5 μmol/J Efficacy @277V
  • 1:1 replacement for 1000W HPS utilizing similar footprint
  • Includes manual dimming and an on-board digital screen for monitoring output levels
  • Compatible with PX Controllers for dimming – 500 pieces per zone
  • Passive heat cooling fins
  • Utilizes LLT connectors compatible with existing PHOTOBIO cable environment
  • Voltage : 120-277V
  • 5 year warranty
  • IP66 rated for water and dust protection

SPECTRA

S4 SPECTRUM
Normalized Photon Output

ELECTRICAL SPECIFICATION


Item Code

| ****

Model

| ****

Spectrum

| ****

Application

| Photon Flux (µmol/s)| Power (W)| Efficacy (µmol/J)| ****

Dimming

| ****

IP

| ****

Weight

| ****

Voltage

| Lifetime to L90
---|---|---|---|---|---|---|---|---|---|---|---
PTB8850LS4X| PHOTOBIO·CX 2125| S4| Vegetative & Flowering| 2125| 850| 2.5| 0-10V| IP66| 27.55 lbs/ 12.50kg| 120-277V| ≥50,000 hr

PRODUCT DIMENSIONS

PARTS LIST
  1. A : PHOTOBIO·CX 2125 fixture
  2. B : 10′ 0–10V Control Cable
  3. C : Eye hook (x5)
  4. D : C hangers (x2)
  5. E : Instructions
  • Avoid direct eye exposure to the light source while it is on.
  • Account for small parts and recycle or dispose of packing material properly.

CABLE HARNESSES & ACCESSORIES (Sold separately)

CABLE HARNESSES
Power cable harness sold separately based upon your specific requirements.

AUTOPILOT PX2 ADVANCED LIGHTING CONTROLLER
Centralized control of up to 1000 PHOTOBIO fixtures. Provides dual zone photoperiod timing, photosynthetic photon flux scheduling, temperature based auto-dimming, high temp shutdown, sunrise/sunset simulation, with built in battery backup.

WARNING – POSSIBLE RISK OF INJURY TO EYES AND SKIN Hazardous optical UV, HEV, and IR radiation may be emitted from the light source. Always wear personal protective equipment ensuring complete shielding of skin and eyes. Avoid prolonged exposure and looking directly at light source.

WARNINGS
Please read these installation instruction carefully and keep it on hand. Before installing, servicing, or performing routine maintenance, follow these general precautions

  • For the installation: if you are unsure about the installation or maintenance of this fixture, consult a qualified licensed electrician and check your local electrical code.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Turn off the power and unplug fixture when you perform any maintenance or cleaning activity.
  • Verify that supply voltage is correct by comparing it with the information on spec label.
  • Avoid hitting, bending or causing mechanical stress to the fixture.
  • DO NOT cover or block any part of the fixture during operation.
  • To ensure optimal performance, the area between the fins of the heatsink may require periodic cleaning. Clean with compressed air or damp lint free cloth.
  • 12″ Clearance must be maintained from any combustible surface.
  • Always provide a well-ventilated environment where ambient temperatures do not exceed 40°C (104°F) regardless of whether the fixtures are in operation or off. Excessive temperatures can inhibit performance and may cause damage or shorten the life of the fixtures and void the warranty.
  • Do not run or store fixtures in the facility unless proper environmental cooling systems are in operation. Facilities that are “shut down” can record excessively high temperatures resulting in premature equipment failure.
  • When calculating cooling needs for your facility, take into consideration BTU load generated by LED fixtures and latent load generated by plant transpiration, human respiration, etc…
  • This IP 66 LED fixture is intended for indoor and greenhouse use only. Avoid high pressure jets of water.
  • Do not expose the fixture to the sulfur dioxide compound. If sulfur application is part of your practice, please make sure to remove the fixtures prior to this process.

Additional safety warnings:

  • Cables shall not be concealed or extended through a wall, floor, ceiling, or other parts of the building structure.
  • Cables shall not be located above a suspended ceiling or dropped ceiling; permanently affixed to the building structure.
  • Cables shall be routed so that they are not subject to strain and are protected from physical damage; and visible over their entire length.
  • Cables shall be used within their rated ampacity as determined for the maximum temperature of the installed environment specified in the instructions.
  • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • ICES-005

INSTALLATION

Be sure that the fixture is unplugged from the power source before installation. Make sure to leave a top clearance of 6 inch and side clearance of 2 inch.

MOUNTING – SUSPENDED MOUNTING WITH FIXTURE HANGER A (Eyebolts are included with the fixture)

  1. Take one eyebolt from the bag, and install into the hole
  2. Install the remaining eyebolts into the holes

MOUNTING – SUSPENDED MOUNTING WITH FIXTURE HANGER B (Sling hanger is not included with the fixture)
Attach the clip end of the sling hanger into the mounting holes

MOUNTING – STRUT MOUNTING WITH FIXTURE HANGER C

  1. Install the C hangers into the M6 holes with M6 bolts (Fig. 5). Be sure the direction of the two Changers matches the direction in the illustration.
  2. Mount the Changers on the truss

POWER CONNECTION

Connect the power cord with the driver AC connector.

DIMMING CONNECTION (OPTIONAL)

The product is equipped with dimming connection supporting 0-10V dimming signal. Use the provided 10′ 0–10V Control Cable to interface with Autopilot PX2 advanced digital & analog lighting controller (APDPX2) to centralize control of up to 1,000 PHOTOBIO fixtures. For connections between aisle to aisle, please use 10′ 0–10V Control Cable.

TECHNICAL SUPPORT

For technical support, please contact Support@Hydrofarm.com.

  • ZONE A
    Controls 500 LED fixtures.

  • ZONE B
    Controls 500 LED fixtures

10′ 0–10V Control Cable
For use with PHOTOBIO CX Drawing is not to scale.

  1. Attach BLACK male end of the control cable to female connector of fixture.
  2. Attach ORANGE female end on the control cable to male connector on linked fixture

Note : Zone A and Zone B can be set up in one room, or in two separate rooms.

IMPORTANT : Do not attach data link cables to AC power cable. Always keep low voltage data cables and high voltage AC power harness as far as possible from each other for stable signal transmission. Avoid coiling data cables as well as AC harnesses in tight coils. Excess cable should be managed by creating long loops as opposed to tight coils.

Thank you for choosing PHOTOBIO by Hydrofarm. For further information about PHOTOBIO products, videos and technical information, please visit Hydrofarm.com or PhantomBio.com.

Get Connected with the Hydrofarm Community:
Like us on Facebook, follow us on Twitter, and check out Hydrofarmtv and PhotobioLED on YouTube and Instagram www.phantombio.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals