Important information
- Only genuine 24 V WindowMaster operators should be connected.
- WUF 110 is a class II product and must be connected according to the rules for its class.
- The WUF 110 must not be covered (maximum casing temperature: 45°C). Should not be exposed directly to the sun
- For indoor use only.
- The surface should be cleaned with a soft damp cloth using a small amount of household cleaner diluted in water.
- The motor interface is to be installed by a certified electrician according to the current electrical regulations.
- Before installation and removal of motor interface WUF 110 disconnect from the mains supply. Ensure that the motor interface cannot be connected unintentionally.
- Never put a hand or the like out of the window before the system is disconnected form supply voltage.
- The packaging can be disposed of together with ordinary household waste.
- In case of damaged power cable, the product is to be discarded.
- Electrical products must be disposed of in conformity with national regulations for electronic waste and not with usual household waste.
- In case of technical problems, please contact WindowMaster, see telephone list below.
Installation instructions for WUF 110 motor interface
Read installation instructions carefully before proceeding and keep for future
reference.
Description
The motor interface is used for WindowMaster window operators as well as installation in the surface mounting system SystemLine. WUF 110 permits 230 V AC operation with WindowMaster 24 V DC operators.
- Fitting and connection: The motor interface is fitted into the window profile next to the WindowMaster operators. The operator is connected using the double pole plug. The 2 meter long 3-core cable is connected to the mains supply through a switch for control.
- Primary mains supply: 230 V AC, 50/60 Hz, 50 VA.
- Nominal output voltage: ±24 V DC / 0.8 A / operating time max. 2 min. per 5 min. (40%).
- IP value: IP 44.
- Dimensions: 160 x 29 x 42 mm (W x H x D).