ilight Plexineon Suspended Dynamic Color Installation Guide

June 3, 2024
ILIGHT

Plexineon Suspended Dynamic Color
**Installation Guide
ilight Plexineon Suspended Dynamic Color fig 2
Plexineon Straight Run Fixture

REV0.1
10252022
**

Plexineon Suspended Dynamic Color

Installation Instructions – Plexineon Suspended Dynamic Color
Models: Plexineon Suspended Mount Dynamic Color and Plexineon Rings Suspended Mount Dynamic Color Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
  2. USE ONLY WITH CLASS 2 POWER UNIT
  3. 24 VOLTS DC
  4. SUITABLE FOR WET LOCATIONS
  5. SUSPENDED MOUNT ONLY

ilight Plexineon Suspended Dynamic Color fig 1 Plexineon Ring Surface Mount
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Models: Plexineon Suspended Mount Dynamic Color and Plexineon Rings Suspended Mount Dynamic Color
Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
  2. USE ONLY WITH CLASS 2 POWER UNIT
  3. 24 VOLTS DC
  4. SUITABLE FOR WET LOCATIONS
  5. SUSPENDED MOUNT ONLY

NOTE: Prior to installation all 24VDC wires must be present within 72” of the installation. Refer to the power supply installation instruction for additional information.
NOTE: More than one person is recommended for this installation.ilight
Plexineon Suspended Dynamic Color fig 3

1.1 Screw mounting clip to stand off hub.
1.2 Fix the plexineon fixture into installed mounting clips. See step A for clipping instructions. Make sure mounting clips are certain distance apart.
NOTE: Standard Clips and Decorative Clips have different required spacing.ilight Plexineon Suspended Dynamic Color fig 4

Install Fixtures into Mounting Clips

ilight Plexineon Suspended Dynamic Color fig 5

A.1 Make an U shape with mounting clip installation tool, insert two edges into mounting clip. Place plexineon fixture insde the shape. Then push the fixture into clip.
A.2 Remove the tool. Make sure mounting clip is clipped right on the grip. ilight Plexineon Suspended Dynamic Color fig 6

NOTE: Prior to installation all 24VDC wires must be present in junction box. Refer to the power supply installation instruction for additional information.
2.1 Align one standoff hub to the junction box and mark the other hubs’ location to the ceiling.
ilight Plexineon Suspended Dynamic Color fig 73.1 Slide power cord end through strain relief, canopy, and cross bar.
Peel back power cord to expose wires.Connect power supply wires to fixture wires. Waterproof wire nuts recommended in this step.
NOTE: Prior to wiring the desired fixture height must be determind to cut off any un-necessary wire.ilight Plexineon Suspended Dynamic Color fig
8

4.1 Insert wire nut and extra wire into junction box. Slide weld stud into the center hole of cross bar. Screw cross bar into junction box holes or the ceiling.
4.2 Slide canopy up to the cross bar and secure by tightening the thumb nut to weld stud.ilight Plexineon Suspended Dynamic Color fig
95.1 Screw cap to threaded post with aircraft cable.
5.2 Fix the aircraft cable into thumbnut, secure by tightening by hand.ilight Plexineon Suspended Dynamic Color fig 106.1 Install the rest of other canopies by similar method.
6.2 If necessary, make any final adjustment to power cord using o-ring.

RGB&RGBW WIRING DIAGRAM

ilight Plexineon Suspended Dynamic Color fig 11

WIRING DIAGRAM
SR-DMX-SPI
Smart Pixel LineLED Decoder
NOTE: Please make sure that power is turned off before wiring. Also, ensure that the correct powersupply (voltage and wattage) is used to power the LED strips connected to the decoder. Follow illustrated wiring diagram. Use screwdriver to open and close connection slots.
NOTE: When connecting two or more LED strip lights or light fixtures, always make sure the signal direction arrows are pointing to same direction
The signal direction arrow should appear on label of each section of LED fixture.ilight Plexineon Suspended Dynamic Color fig
12

OPERATING GUIDE

SR-DMX-SPI
Smart Pixel LineLED Decoder
There are three buttons on the decoderilight Plexineon Suspended Dynamic
Color fig 13 After operation, if no action was taken within 30s, the button lock, and backlight of the screen will turn off.

  1. Long press M button for 5s to unlock the buttons, and the backlight will turn on.
  2. Long press M button for 5s to switch between test mode and decode mode after unlocked.

During test mode, the first line of LCD will show: TEST MODE. Use test mode to verify RGBW Pixel functionality.
Duirng decoder mode, the first line of LCD shows: DECODER MODE. Use decoder mode when connecting to a Controller and for final installation and customization.
The second line of the LCD Display shows the current setting and value. Note: 1 Pixel = 1 Cut Increment MODE TABLE

SETTING LCD DISPLAY VALUE RANGE DESCRIPTION
Built-in Programs hATENDIEsAX: 1-26 See Program Table below
Program Speed TEST MODE
RUN SPEED: 0-7 0: fast, 7: slow
DMX Address DECODER MODE
DMX ADDRESS: 1-512 Address of the starting point/Pixel of a program
DMX Signal RGB DEE)C01:11RBAOSE MX RGB, BGR, etc. N/A
Pixel Quantity DECODER MODE
PIXEL QTY: 1-170(RGB), 1-128 (RGBW) Number of Pixels to follow a program
IC TYPE DECODER MODE
IC TYPE: 2903, 8903,
2904, 8904 2903: N/A, 2904: for RUM,

8903: N/A, 8904: N/A
Color| DECODER MODE
COLOR:| MONO, DUAL,
RGB, RGBW| MONO: N/A,
DUAL: N/A,
RGB: N/A,
RGBW: for RGBW
Pixel Merging /
Pixel Size| DECODER MODE
PIXEL MERGE:| 1-100| Number of Pixels to merge together
RGB Sequence| DECODER MODE
LED RGB SEQ:| RGBW,
BGRW etc.| Sequence of RUM, 24 possible combinations
Integral Control| DECODER MODE
ALL CONTROL:| YES, NO| Yes: Merge all Pixels
No: Maintain individual Pixels or Merged Pixels
Reverse Control| DECODER MODE
REV-CONTROL:| YES, NO| Reverse program order
Overall Brightness| DECODER MODE
BRIGHTNESS:| 1-100| 1: dimmest setting 100: brightest setting

NOTE: When connected to a controller, DMX512 Signal Decoder will stay in “Decoder Mode”.
NOTE: The actual maximum control pixels of the controller are 1360 (2903) ,1024 (2904).
Please set the pixel and pixel combination value according to the actual situation, and DO NOT exceed the maximum.
NOTE: For Program Table
Change: no fading/dimming between color changes
Fade: fade/dim between color changes
Chase: change pixel by pixel
Chase with Trail: change pixel by pixel with fading between

PROGRAM TABLE

PROGRAM NO. PROGRAM DESCRIPTION
1 Solid color: Red
2 Solid color: Green
3 Solid color: Blue
4 Solid color: Yellow
5 Solid color: Purple
6 Solid color: Cyan
7 Solid color: White
8 RGB change
9 Full color change
10 RGB fading
11 Full color fading
12 Red chase with trail
13 Green chase with trail
14 Blue chase with trail
15 White chase with trail
16 RGB chase with trail
17 Rainbow chase with trail
18 RGB chasing and fading
19 Red chasing green, chasing blue
20 Orange chasing purple, chasing cyan
21 Rainbow chase (7 colors)
22 Random twinkle: white over red
23 Random twinkle: white over green
24 Random twinkle: white over blue
25 White fading
26 Off

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
info@luminii.com
www.luminii.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals