ILIGHT SCMR1232 Otago Blue Relay Controller Installation Guide

June 8, 2024
ILIGHT

**ILIGHT SCMR1232 Otago Blue Relay Controller Installation Guide

**

Mounting & Installation

SCMR1232 must be mounted in a suitable enclosure to provide regulatory protection from electric shock hazard as well as protecting the iCANnet data network from tampering that could lead to reduced network security.

Ensure selected enclosure provides adequate cooling ventilation.

Fixing to DIN rail

  1. Fix top clips over DIN rail.
  2. Pull down bottom clip using screwdriver.
  3. Close module towards DIN rail.
  4. Push up bottom clip to fix securely to DIN rail.

Removing from DIN rail

  1. Pull down bottom clip with screwdriver.
  2. Lift module away from DIN rail.

Technical Data

Electrical & Mechanical
Control : Via iLight network connection
iCANnet™ output current: 100mA Max @ nominal 15V
Rating : 32A per channel @ 40°C
Protection : Provided by installer
Output channel current: Maximum 12 x 32A

(Total unit load not to exceed 192A)
Note: Fully loaded channels should be spaced every other channel to prevent heat buildup
Relay outputs: Volt free capable of switching inductive and resistive loads
Terminal Sizes: Loads-maximum cable size: 1 x 10mm² per circuit
Ambient temperature: 2°C-40°C
Relative humidity : 5%-95% max, non-condensing
IP rating : IP20
Installation : Installation must be carried out by a suitably qualified electrician and installed in a suitable DINrail enclosure.
Dimensions : 212mm (w) x 90mm (h) x 58mm (d)
Weight : 0.8kg

Software
For programming SCMR1232, Device Editor V2.11.1 is required
(Packaged with iCANsoft V3.1.7 or later)

  • 32A resistive per channel @ 40°C 20A capacitive per channel @ 40°C

SCMR1232
12 x 32A Relay Controller

Device LEDs and Buttons

Status LED
Green LED flashes – device OK
Data LED
Red LED flashes when messages sent on network.
Alarm LED
Red LED solid on for local initiated alarm
Red LED flashes for network initiated alarm
RS485/DMX LED
Green LED flashes when DMX or RS485 messages are sent or received

Device Identification

Press and release switch.
Sending a message to identify the device on the network (red Data LED flashes).

¡CAN Network Connections

Maximum segment distance: 500m (1640 ft) Devices per segment : 100 (without bridge or repeater) Consult iLight for information on alternative cable types.

IMPORTANT NOTE: Connecting a mains potential cable to the ICAN Network terminals is likley to damage the unit and other devices connected, and invalidate warranty.

Typical Connection Diagram

IMPORTANT NOTE: Connecting a mains potential cable to the ICAN Network terminals is likley to damage the unit and other devices connected, and invalidate warranty.

Dimensions

Typical Schematic

iLight
Usk House, Lakeside Llantarnam Park, Cwmbran, NP44 3HD,
UK t : +44 (0)1923 495495 e: enquiries@iLight.co.uk
www.iLight.co.uk
EU Authorised Representative
Cooper Lighting Netherlands B.V. High Tech Campus HTC 48 Eindhoven 5656 ΑΕ
E &OE. iLight reserve the right to make changes to the equipment without prior notice. Signify Holding
Doc No : 9850-000782-03

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals