STAHL 210747 miniCLIX Plug Connector Flange Socket Owner’s Manual
- June 3, 2024
- STAHL
Table of Contents
STAHL 210747 miniCLIX Plug Connector Flange Socket
Installation Equipment
miniCLIX plug connector Flange socket
- Simple installation and maintenance in Zone 1, safe and fast disconnection under load
- 6+1- pole, rated voltage up to 400 V AC, rated current up to 16 A
- Suitable for harsh industry environments, IP66/ IP68, for Zones 1 and 2
WebCode 8591B
R. STAHL Series 8591/ 2 7- pole, explosion- protected miniCLIX plug connectors disconnect non- instrinsically safe circuits up to 400 V/ 16 A and are used as a hot swap plug connection for signal and data cables. They are available in various versions and materials: Device plugs, flange sockets, plugs/ couplers made of polyamide, nickel- plated brass or stainless steel. The cable can be connected using a crimp or spring clamp terminal. Preinstalled cables for device plugs and flange sockets enable fast and safe installation in the end devices
Technical Data
Explosion Protection
Application range (zones)| 1
2
IECEx gas certificate| IECEx BKI 07.0001X
IECEx gas explosion protection| Ex db eb IIC T6 Gb
ATEX gas certificate| PTB 07 ATEX 1028 X
ATEX gas explosion protection| E II 2 G Ex db eb IIC T6 Gb
Certificates| ATEX (PTB), IECEx (BKI)
Electrical Data
Rated operational voltage AC| 380 – 415 V
Switching capacity| IEC/EN 60947
AC-1: 400 V / 16 A
DC-1: 400 V / 1 A
DC-3: 60 V / 0.5 A
Frequency Hz (for AC)| 50
60
Ambient Conditions
Ambient temperature| -55 °C … +40 °C
Note| – 20 … + 40 °C plastic version
– 20 … + 75 °C plastic version Ith max. 1 A
– 55 … + 40 °C metal version
– 55 … + 75 °C metal version Ith max. 1 A
Mechanical Data
Degree of protection (IP)| IP66
Degree of protection note| IP68 (2 m water column, 1 hour) according to IEC/EN
60529
(with protective caps closed and secured as well as properly fitted and secured compo-
nents)
Mechanical Data
Enclosure material| Plastic
Cable entry| M25
Recommended colour ring coding| Blue
Coding (clock hour position)| 10
Detailed number of poles| 6 P + PE
Weight| 0.1 kg
Weight| 0.22 lb
Mounting / Installation
Connection type| 1.5 mm² crimp
Components
Locking device present| No
Protective cap available| No
Dimensional Drawings (All Dimensions in mm [inches]) – Subject to
Alterations
Accessories
Art. No. | ||
---|---|---|
**** | 165670 |
Anti- twist protection
****| for flange socket, device plug|
154587
---|---|---
Crimping tool
****| for all crimp connection versions up to 4 mm²|
109116
---|---|---
for all crimp connection versions up to 4 mm²|
109116
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding
R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com