Intelligent Energy LW351 Lightweight Hydrogen Regulator
The Lightweight regulator is constructed using a Pressure Tech LW351 regulator with fuel-cell specific modifications, for more information on the LW351 please refer to the Pressure Tech service manual at bit.ly/3IgDeOx
The CE label shows that the product complies with the basic requirements of the applicable directives. For the declaration of conformity contact the manufacturer at servicing@intelligent-energy.com
Safety warnings
- Only qualified technicians trained in high pressure flammable gases must carry out fitting of regulators and filling of cylinders, and do so in accordance with local laws and Health and Safety (H&S) regulations.
- The customer is responsible for ensuring all technicians and pilots are suitably trained, accredited and in compliance with local laws and H&S regulations.
- The customer is responsible for ensuring the safe operation of the Lightweight Hydrogen Regulator.
- Do not open or dismantle the Lightweight Hydrogen Regulator.
- Do not remove any external covers or cowlings.
- Pressurised hydrogen present. Highly flammable!
- Do not use the Lightweight Hydrogen Regulator if the unit is damaged.
- The Lightweight Hydrogen Regulator should be inspected for damage and leak checked prior to use.
When shipping or transporting your Unmanned Aerial Vehicle and Fuel Cell Power
Module (FCPM), the FCPM must always be disconnected from the hydrogen source.
When transporting pressurised gas check for relevant local regulations. This
user manual is intended as a general guidance only and does not purport to
address the specific situations that could potentially arise from the use of
the Lightweight Hydrogen Regulator with pressurised hydrogen systems and their
usage in connection with UAVs. The recipient is responsible for ensuring that
all personnel have read and understood this User Manual before being allowed
to handle, operate, install and store any equipment supplied by Intelligent
Energy.
The recipient must ensure that any personnel responsible for handling the Lightweight Hydrogen Regulator with hydrogen cylinders and operating UAVs are suitably trained and certified in compliance with any applicable local, state and federal laws and regulations and good industry practice. The recipient is responsible for complying with any relevant health and safety policies and procedures that may apply to the operation of UAVs and use and storage of hydrogen on any sites. Intelligent Energy warrants to the recipient and it will repair and replace any defective equipment resulting from the authorised use of the equipment provided, in accordance with the warranty terms. Notwithstanding the above, Intelligent Energy, to the fullest extent permitted by law, accepts no liability (including liability in respect of any error or defects in the Lightweight Hydrogen Regulator) for any damage caused as a result of Recipient’s unauthorised use of the equipment provided. The recipient acknowledges that the manner in which the equipment is stored, used or operated is not under the control of Intelligent Energy Limited. Intelligent Energy has made every effort to ensure that this User Manual is accurate and disclaims liability for any inaccuracies or omissions that may have occurred.
Lightweight Hydrogen Regulator
Product Overview
The Lightweight Hydrogen Regulator has been designed for use with the Intelligent Energy IE-SOAR FCPMs. It is intended to provide the necessary pressure regulation and safety features required to operate an IE-SOAR FCPM. The Regulator has been designed to meet relevant safety standards. It is designed to operate with compressed gaseous hydrogen.
Product specification
Hydrogen Regulator
- Mass 315g
- Maximum regulator (cylinder) pressure 300 or 350 Bar/4350 or 5075 PSI*
- Output pressure 0.9 Bar ± 0.1 Bar/13 PSI ± 1.5 PSI
- PRV set pressure 2 Bar/29 PSI
- Burst disc set pressure 427 or 491 Bar/6190 or 7120 PSI*
- Cylinder interface M18 × 1.5
Lightweight Hydrogen Regulator
Main components
Assembly and connection
Assembly of regulator to cylinder
- Take the cylinder and regulator and inspect for physical damage or debris, reject if visible to the eye.
- Inspect the mating threads for damage or debris, reject if visible to the eye.
- By hand, carefully thread the regulator assembly into the cylinder.
- Tighten the regulator until it is mated flush to the neck of the cylinder.
- Once the regulator is flush, apply a maximum torque of 58Nm (42.8ft.lb).
- Always conduct a leak check on the completed assembly.
- Prior to operation the cylinder will need to be purged to remove air impurities. Contact Intelligent Energy for further information.
Assembly and connection
Filling of cylinder
Only qualified technicians trained in high pressure and flammable gases can
carry out fitting of regulators and filling of cylinders, and do so in
accordance with local laws and Health and Safety (H&S) regulations. A leak
check must be conducted after filling the cylinder. The female swagelok part
number is SS-QF4-B-4PF. This part must be a constituent of the equipment used
to fill the HFLW regulator. Consult local H&S / facilities management for
guidance on storage of cylinders and advisable safety equipment.
Hydrogen fuel
When installing and operating hydrogen systems, hydrogen general safety
guidance should be considered, for more detailed information see: ISO/TR 15916
– Basic considerations for the safety of hydrogen systems Hydrogen purity is
an important consideration for fuel cell performance, it should comply with
the specification in the table below for best performance:
- Fuel Characteristics Fuel Requirements
- Hydrogen concentration > 99.90 %
- Nitrogen, Helium, Argon < 0.10%
- Oxygen < 50 ppm
- Carbon Dioxide < 2 ppm
- Carbon Monoxide < 0.2 ppm
- Ammonia < 0.1 ppm
- Sulphur containing compounds < 4 ppb
- Max particle concentration < 1 mg/kg
- Max particle diameter < 75 μm
For more details about hydrogen quality see the user manual for your FCPM or contact Intelligent Energy Product Support, see Section 6
Hydrogen connection
The Lightweight Hydrogen Regulator is designed to be connected to an
Intelligent Energy FCPM, please refer to the FCPM user manual for details of
how to make the hydrogen connection to that unit. Ensure the hydrogen cylinder
and FCPM are securely mounted before proceeding.
- Verify that the connector O-rings are in place and free from damage or debris.
- Align the hose connector path with the regulator pins.
- Push the hose connector and twist anti-clockwise. It will click when located.
Refuelling
There are multiple ways to fill cylinders and Intelligent Energy has application notes available for some fill options. Contact Intelligent Energy Product Support at servicing@intelligent-energy.com for details.
Troubleshooting
Symptom | Reason(s) | Action |
---|---|---|
High H2 pressure fault | Gas pressure regulation fault | Contact Intelligent |
Energy Product Support
Low H2 pressure fault| No hydrogen supplied from cylinder
Cylinder is empty
Gas pressure regulation fault
| 1. Check cylinder pressure, refill if needed
2. Inspect the pressure transducer cable Replace if damaged
If the steps above do not resolve the issue, contact Intelligent Energy Product Support,
see Section 6
Loss of cylinder pressure| Leak between cylinder and regulator
Leak from the regulator
| 1. Place cylinder and regulator in a well- ventilated space, preferably outdoors
2. Purge the gas from the cylinder by lifting
the cap of the PRV, see diagram in section 2.2
3. When the cylinder is empty. A person trained in the use of pressurised gas should remove the regulator from the cylinder and inspect the sealing o-ring. Replace if damaged
4. Reassemble and refill the cylinder
5. Check for leaks
If the steps above do not resolve the issue, contact Intelligent Energy Product Support,
Contacting Intelligent Energy Product Support
For all other issues and questions please contact your local Intelligent Energy representative or the Product Support team by email servicing @intelligent-energy.com
End of life treatment and disposal
When the Lightweight Hydrogen Regulator or cylinder reaches end of life please
contact Intelligent Energy for support with reconditioning or disposal at
servicing@intelligent-energy.com
© Intelligent Energy Limited 2022. All Rights Reserved. The information contained herein is the intellectual property of Intelligent Energy Ltd and it may not be copied or reproduced in any format. The information contained in this publication is intended only as a guide and is subject to change as a result of the constant evolution of Intelligent Energy’s business and its technology. This publication and its contents do not include all details which may be relevant to particular circumstances and should not be regarded as being a complete source of Information. To the fullest extent permitted by law, Intelligent Energy offers no warranty as to the accuracy of the content of this publication, shall not be liable for the content of this publication and no element of this publication shall form the basis of any contractual relationship with a third party. Printed August 2019. 53527-IE-UM-201908 Published by: Intelligent Energy Ltd, Charnwood Building, Holywell Park, Ashby Road, Loughborough LE11 3GB. Tel: +44 (0) 1509 271 271 Document No: 10010368 (Registered in England with company number: 03958217).
T +441509 271 271 E servicing@intelligent-energy.comIntelligent Energy Charnwood Building, Ashby Road, Loughborough, LE11 3GB, UK www.intelligent-energy.com
Intelligent Energy Proprietary and confidential data. Copyright © 2022 Intelligent Energy. All rights Reserved. Confidential external
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>