Specifications
1.1 General
Power | 550, 650 or 750 Watt |
---|---|
PCIe Connector | 4x 6+2-Pin |
Fan | 140 mm Fan with Fluid Dynamic Bearing |
Efficiency | 20 % Load: min. 87 % |
50 % Load: min. 90 %
100 % Load: min. 87 %
80 PLUS Certification| Gold
1.2 Package Contents
-
WPM Gold ZERO
-
Power Cord
-
Cable Bag
-
Set with Modular Cables*
-
Set of Mounting Screws
-
Manual
-
All cables shown in the cable chart are included in the packaging (see page 8).
1.3 Model-Specific
Model|
WPM Gold ZERO 550
---|---
Input (AC)|
Voltage
| Current|
Frequency
100 – 240 V| 8 A / 4 A| 47 – 63 Hz
Output Voltage (DC)| +3.3 V| +5 V| +12 V| -12 V| +5 Vsb
Max. Output Current| 20 A| 20 A| 45 A| 0.3 A| 2.5 A
Max. Combined Power| 110 W| 540 W| 3.6 W| 12.5 W
Total Power| 550 W
Model|
WPM Gold ZERO 650
---|---
Input (AC)
| Voltage| Current|
Frequency
100 – 240 V| 10 A / 5 A| 47 – 63 Hz
Output Voltage (DC)| +3.3 V| +5 V| +12 V| -12 V| +5 Vsb
Max. Output Current| 20 A| 20 A| 53 A| 0.3 A| 2.5 A
Max. Combined Power| 110 W| 636 W| 3.6 W| 12.5 W
Total Power| 650 W
Model|
WPM Gold ZERO 750
---|---
Input (AC)|
Voltage
| Current|
Frequency
100 – 240 V| 10 A / 5 A| 47 – 63 Hz
Output Voltage (DC)| +3.3 V| +5 V| +12 V| -12 V| +5 Vsb
Max. Output Current| 20 A| 20 A| 62 A| 0.3 A| 2.5 A
Max. Combined Power| 120 W| 744 W| 3.6 W| 12.5 W
Total Power| 750 W
Safety Standards and Protections
This power supply is designed for a mains voltage of 100 – 240 volts. It
complies with CE, FCC and CB safety standards and has the following protection
features:
Over Power Protection (OPP)
If the system demands more power than the specifications allow, the power
supply will switch off to protect the electronics from damage.
Over Voltage Protection (OVP)
This function shuts off the power supply to protect the components as soon as
the internal voltage exceeds specified limits.
Short Circuit Protection (SCP)
Should a short circuit occur, the SCP function switches off the power supply
and protects the electronics from damage.
Installation
3.1 Removal of Existing Power Supply from PC Case
If installing into an empty PC case, proceed to the section “Installing the
Power Supply in a PC Case“.
For a PC case with an already installed power supply, first remove this from
the case. Proceed as follows:
- First shut down your PC. Then disconnect the power cord from the wall outlet and the power supply.
- Now open the PC case (for additional information, refer to the manual of your PC case).
- Disconnect all cables between the power supply and the other PC components (e.g. mainboard, drives, fans, etc.).
- Remove the mounting screws connecting the power supply to the PC case and then carefully remove the power supply from the case.
3.2 Installing the Power Supply into a PC Case
-
Insert the power supply into the PC case and place it against the power supply mount on the rear panel.
For additional information, see the manual for your PC case. -
Attach the power supply from the outside of the case using the provided screws. Ensure that the fan and air vents of the installed power supply are not covered.
-
Use the supplied cables to connect the power supply to the components. The connectors are coded to avoid connecting incorrectly. Please pay attention to the labeling of the connections on the power supply.
Connection Options
The WPM Gold ZERO has a semi-modular cable system. In addition to the permanently attached ATX cable and the 4+4-pin CPU cable, only those cables are used on the power supply which are actually needed when connecting hardware and peripherals. The complete wiring and the inside of the case thus remain tidy, and the air flow is not unnecessarily obstructed. The WPM Gold ZERO has the following connection options:
A 2x Sockets for 4+4-Pin CPU Connector* (CPU) or 6+2-Pin PCIe Connector (PCIe)
B 4x Sockets for SATA Connector (PERIPHERAL/SATA)
- With the included second 4+4-pin CPU cable, which can be connected to one of the two PCIe/CPU sockets on the power supply, power-hungry systems can be operated without an adapter. In this case, there are still 2x 6+2-pin connectors for powering graphics cards.
Cable Diagram
The WPM Gold ZERO comes with a range of modular ribbon cables with the following connectors:
A 1x Cable with 24-Pin Mainboard Connector (permanently attached cable)
B 2x Cables each with 1x 4+4-Pin CPU Connector (1x permanently attached cable)
C 2x Cables each with 2x 6+2-Pin PCIe Connectors
D 3x Cables each with 3x SATA Connectors
E 1x Cable with 3x IDE Connectors 1x Floppy Connector
Please note: Make sure that only the included set of modular cables is
used. The use of other cables (e.g. older power supply cables from Sharkoon or
cables from other manufacturers) can result in damage to the device and
connected peripherals.
Connecting
6.1 Connection for Mainboard and Graphics Card
-
Connect the cable with the 24-pin mainboard connector to the appropriate sockets on the mainboard.
-
If your mainboard has an additional 4-pin / 4+4-pin CPU connection, plug the connector into the socket on the mainboard and the power supply.
Please note: The type of connection on the mainboard depends on the manufacturer and may therefore vary.
For additional information, see the manual for your mainboard. -
If your PCIe graphics card requires additional power, connect the 6-pin or 6+2-pin PCIe connector to the power supply to ensure a stable electrical current to your graphics card.
6.2 Connecting Drives and Other Peripheral Devices
Connect drives and peripherals to the power supply.
Please note: For additional assistance, refer to the manuals for your drives
and peripherals.
6.3 Checking all Connections
First, make sure all devices have been connected properly. Close the PC case.
Then connect the power cord to the power supply and to a wall outlet. Then
switch on the power supply using the on/off switch on the back of the device.
This completes the installation.
Please note: The cable connectors are designed to prevent improper
connection. If the connector does not fit into the sockets of main board,
drive or peripheral device, please check if the connector and socket are being
connected in the correct orientation. Do not try to force a connector into a
socket using the incorrect alignment, nor modify the components, otherwise the
power supply and your hardware will be damaged. The Sharron warranty does not
cover any damage that has been caused by improper handling.
Troubleshooting
If the power supply is not functioning correctly, check the following points:
- Is the power cord correctly connected to the wall outlet and the socket of the power supply?
- Make sure the on/off switch is in the “I“ position.
- Check that the 24-pin ma-inboard connector and the 4+4-pin CPU connector are correctly connected to the main board.
- Check if the connectors of the cables are firmly plugged into the sockets of the peripherals.
- Pull the power plug out of the wall outlet and leave the power supply without power for approximately 10 minutes. This will cause a reset of the protective circuits.
If the system still fails to function, please contact support@sharkoon.com.
Legal Disclaimer
For potential loss of data, especially due to inappropriate handling,
Sharkoon assumes no liability.
All named products and descriptions are trademarks and/or registered
trademarks of the respective manufacturers and are accepted as protected.
As a continuing policy of product improvement at Sharkoon, the design and
specifications are subject to change without prior notice. National product
specifications may vary.
All rights reserved especially (also in extracts) for translation, reprinting,
reproduction by copying or other technical means. Infringements will lead to
compensation. All rights reserved especially in case of assignation of patent
or utility patent. Means of delivery and technical modifications reserved.
Disposal of Your Old Products
Your product is designed and manufactured with high quality materials and
components, which can be recycled and reused.
When this crossed-out wheeled bin symbol is attached to a product, it means
the product is covered by the European Directive 2012/19/EU.
Please be informed about the local separate collection system for electrical
and electronic products.
Please act according to your local rules and do not dispose of your old
products with your normal household waste. The correct disposal of your old
product will help prevent potential negative consequences to the environment
and human health.
Sharkoon Technologies GmbH
Grüninger Weg 48
35415 Pohlheim
Germany
© Sharkoon Technologies 2019
Documents / Resources
|
Sharkoon WPM Gold ZERO Reliable Power
Supply
[pdf] User Guide
WPM Gold ZERO, Reliable power supply, power supply, WPM Gold ZERO Reliable
Power Supply
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>