ETNA KIF780ZT Induction Hobs
WARNING
The fitting of the appliance should only be carried out by a registered and qualified installer. Please read the safety regulations.
Preparations for installation
Pictograms used
- Important information
- Electrical connection
Free space around the appliance
A (mm) | C (mm) | D (mm) |
---|---|---|
min. 650 | min. 450 | min. 40 |
This appliance must be earthed.
The electrical connection must comply with national and local regulations.
Connected load
L1 (W) | L2 (W) | L3 (W) | Total load (W) | |
---|---|---|---|---|
KIF780ZT | 3600 | 3600 | 0 | 7200 |
KIF780DS | 3600 | 3600 | 0 | 7200 |
KIF790ZT | 3600 | 3600 | 0 | 7200 |
A (mm) | B (mm) | C (mm) | D (mm) | |
---|---|---|---|---|
KIF780ZT | 800 | 520 | 54,1 | 58,1 |
KIF780DS | 800 | 520 | 54,1 | 58,1 |
KIF790ZT | 900 | 520 | 54,1 | 58,1 |
A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | |
---|---|---|---|---|---|
KIF780ZT | 750 | 600 | 490 | 50 | 56 |
KIF780DS | 750 | 600 | 490 | 50 | 56 |
KIF790ZT | 750 | 600 | 490 | 50 | 56 |
Accessibility!
Placing sealing tape
Electrical connection
-
2N 380-415V 50/60Hz – 2x 16A
-
2 fase – 1 nul / 2 phases – 1 neutral
-
2-2N 220-240V 50Hz – 2x 16A
-
2 fase – 2 nullen / 2 phases – 2 neutral
-
1 1N 220-240V 50/60Hz – 1x 32A
-
1 fase – 1 nul / 1 phase – 1 neutral
-
3N 380-415V 50/60Hz – 3x 16A
-
3N 380-415V 50/60Hz – 3x 16A
Consult the wiring diagrams on the back of the appliance/Make the required connections on the connecting block.
You can find the most recent version of the installation instructions on our website.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>