ETNA KI460ZT Induction Hobs Instruction Manual
- June 4, 2024
- ETNA
Table of Contents
KI460ZT Induction Hobs
Instruction Manual
The fitting of the appliance should only be carried out by a registered and qualified installer. Please read the safety regulations.
Preparations for installation
Pictograms used
Important information
Electrical connection
This appliance must be earthed.
The electrical connection must comply with national and local regulations.
| A (mm)| B (mm)| C (mm)| D (mm)
---|---|---|---|---
I K4062M| 600| 522| 50| 54
I K4062R| 598| 520| 50| 54
I K4064M| 600| 522| 50| 54
1K4064SR/R| 598| 520| 50| 54
I K4073M| 705| 522| 50| 54
IK4083M| 800| 522| 50| 54
IK4084M| 800| 522| 50| 54
I K4084R| 798| 520| 50| 54
Free space around the appliance
A (mm) C (mm) D (mm)
min. 650 min. 450 min. 40
Connected load
| L1 (W)| L2 (W)| L3 (W)| Total load (W)
---|---|---|---|---
IK4062M| 3700| 3700| 0| 7400
IK4062R| 3700| 3700| 0| 7400
IK4064SR| 3680| 0| 0| 3680
IK4064M| 3600| 3600| 0| 7200
IK4064R| 3600| 360| 0| 7200
IK4073M| 3700| 3700| 0| 7400
IK4083M| 3700| 3700| 0| 7400
IK4084M| 3600| 3600| 0| 7200
IK4084R| 3600| 3600| 0| 7200
| A (mm)| B (mm)| C (mm)| D (>mm)| E (>mm)
---|---|---|---|---|---
IK4062/IK4064| 560| 600| 490| 40| 70
IK4073| 560| 600| 490| 40| 70
IK4083/IK4084| 750| 600| 490| 40| 70
Placing sealing tape
Electrical connection
2N 380-415V 50/60Hz – 2x 16A
2 fase – 1 nul / 2 phases – 1 neutral
2 Phasen – 1 Nullanschluss / 2 phases et 1 neutre
2-2N 220-240V 50Hz – 2x 16A
2 fase – 2 nullen / 2 phases – 2 neutral
2 Phasen – 2 Nullanschlusse / 2 phases et 2 neutres
1 1N 220-240V 50/60Hz – 1x 32A
1 fase – 1 nul / 1 phase – 1 neutral
1 Phase – 1 Nullanschluss / 1 phase et 1 neutre
3N 380-415V 50/60Hz – 3x 16A
3 fase – 1 nul / 3 phases – 1 neutral
3 Phasen- 1 Nullanschluss / 3 phases et un neutre
Make the required connections on the connecting block.
You can find the most recent version of the installation instructions on our website.