LIEBHERR GGPv Commercial Freezer User Guide
- June 3, 2024
- LIEBHERR
Table of Contents
GGPv Commercial Freezer
Original operating instructions
Commercial freezer
Read the operating instructions before switching on for the first time
Page 12 EN
GGPv 6540 GGPv 1440 BGPv 6520 BGPv 6570 BGPv 8420 BGPv 8470
7085 157-03
Content
Priority of warnings……………………………………………………….. 12 Safety instructions and
warnings ……………………………………. 12 Symbols on the appliance ……………………………………………… 13
Intended use………………………………………………………………… 13 Foreseeable incorrect
use……………………………………………… 13 Declaration of conformity ………………………………………………. 13
Noise emissions from the appliance ……………………………….. 13 Climate rating
………………………………………………………………. 13 EPREL database ………………………………………………………….. 13
Description of the appliance…………………………………………… 14 Setting up
……………………………………………………………………. 14 Levelling the appliance………………………………………………….. 14
Electrical connection…………………………………………………….. 14 Appliance dimensions
…………………………………………………… 15 Equipment …………………………………………………………………… 15 Operating and
control elements……………………………………… 16 Switching the appliance on and off
…………………………………. 16 Setting the temperature…………………………………………………. 16 Temperatur
display mode………………………………………………. 16 SuperFrost…………………………………………………………………… 16
Door open alarm…………………………………………………………… 16 Setting the delay time for the door
open alarm………………….. 16 Deactivating the audible warning signal function
………………. 17 Alarm test ……………………………………………………………………. 17 Alarm messages
………………………………………………………….. 17 Adjusting the alarm parameters ……………………………………… 17
Resetting the parameters to factory settings ……………………. 17 Storing
………………………………………………………………………… 18 Defrosting……………………………………………………………………. 18
Activating the defrost function manually ………………………….. 18 Setting the display
indication for the defrost phase …………… 18 Cleaning ………………………………………………………………………
18 Malfunctions………………………………………………………………… 19 Possible error messages in the
display……………………………. 19 Disposal notes……………………………………………………………… 19 Shutting your
appliance down ………………………………………… 19 Changing over door hinges GGPv 65.. / BGPv
84.. ……………20
Priority of warnings
DANGER
identifies a situation involving direct danger which, if not obviated, may result in death or severe bodily injury.
WARNING identifies a dangerous situation which,
if not obviated, may result in death or severe bodily injury.
CAUTION
identifies a dangerous situation which, if not obviated, may result in minor or medium bodily injury.
NOTICE
identifies a dangerous situation which, if not obviated, may result in damage to property.
Note
identifies useful information and tips.
Safety instructions and warnings
– WARNING:do not seal ventilation openings on the appliance housing or
enclosure.
– WARNING: only use the mechanical devices or other aids recommended by the
manufacturer to help speed up the defrosting process.
– WARNING: do not damage the refrigerant circuit.
– WARNING: do not use any electrical devices in the refrigerator compartment
which do not comply with the design recommended by the manufacturer.
– WARNING: the mains cable must not be damaged while installing the appliance.
– WARNING: multi-sockets or distributor strips and other electronic devices
(such as halogen transformers) must not be positioned and operated at the rear
of appliances.
– WARNING: this appliance must be secured as described in the operating
instructions to rule out any potential risks due to its instability.
– This appliance can be used by children of 8 years old and over, and also by
persons with restricted physical, sensory or mental capacity or lack of
experience and knowledge, if they are supervised or have been instructed on
safe use of the appliance and understand the resulting risks.Children must not
be allowed to play with the appliance. Cleaning and user maintenance must not
be carried out by children without supervision.
– Do not store any explosive substances, such as aerosol containers with
flammable propellant gas, inside the appliance.
– To prevent injury and damage to property, the appliance should only be
installed by two people.
– After unpacking it, check the appliance for signs of damage. Contact the
supplier if it is damaged. Do not connect the appliance to the mains power
supply.
– Avoid prolonged skin contact with cold surfaces (e.g. chilled/frozen
products). If necessary, take safety action (e.g. gloves).
– All repairs and work on the appliance may only be carried out by customer
service personnel or other trained personnel. The same applies to changing the
mains power cable.
12
– Only carry out repair and other work on the appliance when the mains plug
has visibly been disconnected.
– Only install, connect and dispose of the appliance as described in these
operating instructions.
– In the event of a fault, pull out the plug or switch off the fuse.
– When disconnecting the appliance from the mains, pull on the plug. Do not
pull on the cable.
– Ensure that food which has been stored for too long is not consumed. Dispose
of food which has been stored for too long properly.
– Do not allow naked flames or ignition sources to enter the appliance.
– Alcoholic drinks or other vessels containing alcohol should be sealed
tightly for storage.
EN
Intended use
The appliance is suited only for cooling food.
This appliance may be used to display food and drink in retail sales outlets.
It is suitable for commercial use, for example in restaurants, canteens,
hospitals and in commercial businesses such as bakeries, butchers’ shops,
supermarkets, etc.
This professional refrigeration appliance is designed for storing frozen food.
It is not designed for the presentation of food or for the removal of food by
customers.
The appliance is designed for use in enclosed rooms. All other types of use
are not permitted.
Foreseeable incorrect use
Do not use the appliance for the following applications:
· Storage and cooling of medicines, blood plasma, laboratory preparations or
similar substances and products subject to the Medical Devices Directive
2007/47/EC.
· Use in potentially explosive atmospheres. · Use outdoors or in areas where
it is exposed to splash water or
damp conditions.
Incorrect use of the appliance will result in damaging or spoiling the goods
stored in it.
Symbols on the appliance
The symbol can be located on the compressor. It refers to the oil in the
compressor and indicates the following danger: swallowing or inhaling can be
fatal. This is only relevant for recycling. There is no danger in normal
operation.
Warning about inflammable substances.
Declaration of conformity
The refrigerant circuit has been tested for leaks. The appliance complies with
the relevant safety regulations and EU Directives 2006/42/EG, 2014/30/EU,
2009/125/EG and 2011/65/EU.
Noise emissions from the appliance
The noise level while the appliance is operating is below 70 dB(A) (relative
noise level 1 pW).
A sticker to this effect may be applied to the rear of the appliance. It refers to the foampadded panels in the door and/or the housing. This is only relevant for recycling. Do not remove the sticker.
Climate rating
The climate rating indicates at what room temperature the appliance may be
operated to achieve full cooling capacity and what the maximum humidity level
in the area around the appliance may be to ensure that no condensation forms
on the exterior housing.
The climate rating is indicated on the type plate.
Climate rating
3 4 5 7
Max. room temperature
25 °C 30 °C 40 °C 35 °C
Max. relative humidity 60% 55% 40% 75%
The minimum room temperature at the place of installation is 10°C.
EPREL database
As from 1 March 2021, information about energy labelling and ecodesign
requirements will be available in the European product database (EPREL). You
can access the product database using the following link:
https://eprel.ec.europa.eu/. You will be asked to enter the model identifier.
You will find the model identifier on the type plate.
13
Description of the appliance
GGPv 1440
Setting up
· Do not place the appliance in direct sunlight or near cookers, radiators and
similar sources of heat.
· Do not place heat-emitting appliances, e.g. microwave oven, toaster, etc.,
on top of the appliance.
· The more coolant there is in the appliance, the larger the room in which the
appliance is installed must be. If the room is too small, any leak may create
a flammable mixture of gas and air. For each 8 g of coolant the installation
space must be at least 1 m³. Information on the coolant is on the model plate
inside the appliance.
· There must be a gap of at least 30 cm between the upper edge of the
appliance and the ceiling.
GGPv 6540, BGPv 6520, BGPv 6570, BGPv 8420, BGPv 8470
(1) Operating and control elements (2) Lock (3) Type plate (4) Grid shelves
(5) Stacking mark (6) Stellfüße (7) Adjustable-height feet
NOTICE
The maximum load per grid shelf is 60 kg.
Cleaning water drain opening A drain hose with an R 3/4 connection can be
fitted to the underside of the appliance. The water which collects in the
interior during cleaning can be drained off in this way. An angled connector
is supplied with the appliance.
Levelling the appliance
Compensate floor unevenness using the adjustable feet. To alter the height,
rotate the bottom section of the respective adjustable foot.
WARNING The height of the foot can be adjusted from 120 mm to 170 mm.
Do not set the adjustable foot to a height greater than 170 mm! The bottom
section of the adjustable foot can become loose and the appliance may then tip
over.
This can lead to serious or even fatal injuries.
NOTICE
The appliance must be aligned horizontally and vertically. If the appliance is
not level, the main body of the appliance can be deformed and the door will
not close properly.
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type plate. The
position of the type plate is shown in the section entitled Description of the
appliance.
The socket must be properly earthed and protected by a fuse. The tripping
current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appliance and must be easily
accessible.
Do not connect the appliance using an extension cable or extension socket.
Do not use stand-alone inverters (conversion of direct current to alternating
current/threephase current) or energy-saving plugs. Risk of damage to the
electronic control system!
14
Appliance dimensions
GGPv 6540 BGPv 6520, BGPv 6570
BGPv 8420, BGPv 8470
GGPv 1440 equipment
Fit the supplied shelf rails to the right and left of the vertical bar.
EN
Equipment
GGPv 1440
Suspend the rails at the desired height, by inserting into the rear clip-in
strip first and then clipping in at the front.
Intermediate shelves
Insert the grid shelves.
Safety lock The lock is equipped with a safety mechanism. Locking the
appliance · Insert the key as shown by arrow 1. · Turn the key 180° (2). To
unlock the appliance, the same procedure must be repeated in the same order.
Place the supplied intermediate shelves onto the shelf rails.
NOTICE
The maximum load per intermediate shelf is 20 kg.
BGPv equipment
The BGPv series is equipped with L-shaped support rails to accommodate baking
trays.
Depending on the height of the goods to be stored, you can adjust the position
of the support rails in intervals of 27,5 mm.
First slide bars into the rear clip-in upright at the desired height and then
hang in position at the front.
15
Operating and control elements
On/Off button (switching the appliance on and off) Selection buttons
SuperFrost button Audible alarm Off button Defrost button (for manually
activating the defrost function) Enter button Symbols in the display
Compressor is running LED flashing – refrigeration unit switches on after a
delay. The compressor will start automatically after the pressure in the
refrigerant circuit has equalised. Fan is running Appliance is defrosting
SuperFrost is activated Alarm function The appliance has suffered a fault.
Contact the customer service department.
Switching the appliance on and off
Connect the appliance to the mains. Display = OFF Switching the appliance on
Press for approx. 5 seconds. Display = ON Switching the appliance off Press
for approx. 5 seconds. Display = OFF
Setting the temperature
Press for 1 second. The temperature display flashes. To increase the
temperature (warmer): press button . To reduce the temperature (colder): press
button . Press again. The desired temperature setting is saved. Note The
temperature in the warmest area of the interior may be higher than the
temperature setting. If the door is left open for a lengthy period, the
temperature in the appliance’s compartments may rise dramatically. 16
Temperatur display mode
The temperature display can be switched between degrees Celsius and degrees
Fahrenheit. Factory setting is degrees Celsius.
Press for 5 seconds. Display =
Press . Display =
Use button or to select the desired setting.
0 = °C 1 = °F
Press . Display =
Press for 5 seconds.
The electronic control system will switch back to normal operating mode.
SuperFrost
Use SuperFrost, to rapidly cool large amounts of food. When SuperFrost is
activated, the appliance operates with maximum cooling performance. Activating
SuperFrost Press for approx. 3 seconds. Display =
Place the fresh food in the appliance.
The electronic control system will automatically switch back to normal
operating mode.
Prematurely deactivating SuperFrost Press for approx. 3 seconds. Display =
Door open alarm
When the door is opened, the LED lights up and the temperature display begins
to flash.
When the door has been left open for more than 240 seconds, the LED begins to
flash, and and the temperature indication flash alternately in the display.
The audible warning signal sounds (unless the audible warning signal function
has been deactivated).
If the door has to stay open for longer in order to insert items to be cooled,
cancel the audible warning signal by pressing button .
Setting the delay time for the door open alarm
The time before the audible warning signal sounds after the door has been
opened can be adjusted.
Press for 5 seconds. Display =
Press until
appears in the display.
Press . Display =
Setting range = 1 – 5 minutes.
Use button or to select the desired setting.
Press . Display =
Press for 5 seconds.
The electronic control system will switch back to normal operating mode.
Deactivating the audible warning signal function
The audible warning signal function can be completely deactivated if
necessary.
Press for 5 seconds. Display =
Press until appears in the display.
Press . Display =
Use button or to select the desired setting.
0 = audible warning signal function activated
1 = audible warning signal function deactivated
Press . Display =
Press for 5 seconds.
The electronic control system will switch back to normal operating mode.
Alarm test
This test checks the function of the internal and any external connected alarm
device.
The appliance does not stop its refrigerating function during this test.
Press + for 5 seconds.
· The display will change to a temperature value of 0.2°C below the set upper
alarm limit.
· The temperature value will now rise by 0.1°C every 2 seconds.
· When the upper alarm limit is reached, will appear in the display. An
external alarm unit connected to the floating alarm output will now be
activated.
· The temperature value will continue to rise up to 0.2°C above the upper
alarm limit.
· The same process will take place automatically for the lower alarm limit.
will appear in the display.
The LED will be lit during the test.
The electronic control system will automatically switch back to normal
operating mode.
Cancelling the test prematurely
Press for 5 seconds.
Note If the values of the upper and lower alarm limit (AL and AH in the
section entitled “Adjusting the alarm parameters”) are set to 0,
and will appear in the display during this test.
Note For a realistic temperature alarm test, an additional delay time (60
minutes) applies as well as the adjustable alarm parameters AL, AH and Ad.
After a door has been opened or a defrosting process, the alarm delay Ad will
be extended by an additional delay time (60 minutes). This additional delay
time must not be changed. This means that a temperature alarm will appear
later after a door has been opened or a defrosting process than is actually
set using parameter Ad.
Alarm messages
1. LED flashes in the display
EN
If appears in the display, the appliance has a fault. Consult your nearest customer service point.
2. LED flashes in the display; the display reads HI or LO The interior is too
warm (HI) or too cold (LO).
The audible warning signal sounds (unless the audible warning signal function
has been deactivated).
Adjusting the alarm parameters
The alarm limits (difference to the set temperature) and the alarm delay
(delay until alarm sounds) can be adjusted.
Note After a door has been opened or a defrosting process, the alarm delay Ad
will be extended by an additional delay time (60 minutes). This additional
delay time must not be changed. This means that a temperature alarm will
appear later after a door has been opened or a defrosting process than is
actually set using parameter Ad.
Press for 5 seconds. Display =
Press until appears in the display.
= Lower alarm limit
Press . Display = temperature difference in °C
Use button or to select the desired setting. Set positive values only.
Press . Display =
Press . Display = Upper alarm limit
Press . Display = temperature difference in °C
Use button or to select the desired setting. Set positive values only.
Press . Display =
Press . Display =
Press . Display = alarm delay in minutes
Use button or to select the desired setting.
Press . Display =
Press for 5 seconds.
The electronic control system will switch back to normal operating mode.
Resetting the parameters to factory settings
The alarm limits and sensor calibration values can be reset to the factory
settings using this function.
Pull out the mains plug.
Keep pressed and connect the mains plug.
Display =
Press . Display =
The electronic control system will switch back to normal operating mode.
17
Storing
The grid shelves can be moved to accommodate different height bottles or
packages.
(1) The ventilation slots on the inside must not be covered!
(2) Stacking mark Only load the top shelf up to the stacking mark. This is
important so as to ensure that the air can circulate properly and the
temperature is even throughout the interior.
NOTICE
Store raw meat or fish in clean sealed containers on the bottom shelf of the
refrigerator/freezer compartment so that it cannot come into contact with any
other food or drip liquid onto it. A failure to follow these instructions may
result in the food being spoilt.
Defrosting
The refrigerator compartment defrosts automatically.
Activating the defrost function manually
If the door has been left slightly open for a long time, a layer of ice may
form in the interior and on the cooling plate. The defrost function can then
be activated manually. Press for 3 seconds. Display = + The electronic control
system will automatically switch back to normal operating mode. Display =
Setting the display indication for the defrost phase
Press for 5 seconds. Display = Press until appears in the display. Press .
Display = Use button or to select the desired setting.
0 = Symbol + alternating display of and the current temperature in the
interior of the appliance.
1 = Symbol + temperature before the start of the defrost phase.
2 = Symbol + . Press . Display = Press for 5 seconds. The electronic control
system will switch back to normal operating mode.
Cleaning WARNING
Before cleaning, always disconnect the appliance from the mains. Pull out the
plug or switch off the fuse.
Surfaces which may come into contact with food and accessible drain systems
must be cleaned at regular intervals.
CAUTION Risk of damage to the appliance components and risk of injury due to
hot steam.
Do not use steam cleaning equipment to clean the appliance.
· Clean the inside, equipment parts and outer walls with lukewarm water and a
little detergent. Do not use chemical solvents or any cleaning agents
containing sand or acid.
· To avoid short-circuits, ensure no cleaning water penetrates into the
electrical components when cleaning the appliance.
· Dry all parts well with a cloth.
· Use a commercially available stainless-steel cleaning agent for stainless-
steel appliances.
· Do not damage or remove the type plate on the inside of the appliance. It is
very important for servicing purposes.
Cleaning the dust filter
Clean the dust filter at least twice per year!
Remove the plug!
1. Remove the dust filter by lifting upwards.
2. Clean the dust filter with water and detergent.
3. Reinstall the dust filter.
18
Malfunctions
You may be able to rectify the following faults by checking the possible
causes yourself:
· Appliance does not function: Is the appliance switched on? Is the plug
correctly fitted in the mains socket? Is the fuse intact?
· The temperature is not low enough: Is the temperature setting correct (see
“Setting the temperature”)? Does the separately installed thermometer show
the correct
reading? Is the ventilation system working properly? Is the appliance set
up too close to a heat source?
· Temperature alarm test does not work as required. See ,,Alarm test” and
,,Adjusting the alarm parameters”
If none of the above causes apply and you cannot rectify the fault yourself,
contact the nearest customer service department stating the
1 type designation , service 2 number and appliance 3 number as indicated on
the
type plate.
The position of the type plate is shown in the section entitled Description of
the appliance.
Disposal notes
The appliance contains reusable materials and should be disposed of properly –
not simply with unsorted household refuse. Appliances which are no longer
needed must be disposed of in a professional and appropriate way, in
accordance with the current local regulations and laws.
EN
Do not damage the refrigerant circuit of an appliance that is no longer needed during its disposal.
This appliance contains inflammable gases in the refrigerant circuit and insulation foam.
Your local council or a waste disposal contractor can provide information about how to dispose of the appliance correctly.
Shutting your appliance down
If the appliance is left empty for a lengthy period, it must be switched off,
defrosted, cleaned and dried and the door is to be left open to prevent mould
formation.
Possible error messages in the display
Error code E0, E1, E2, rE EE, EF dOr
HI
LO
Error
Temperature sensor defective Electronic control system error Appliance door
open for too long Temperature inside appliance too high (too warm)
Temperature inside appliance too low (too cold)
Action
Contact the customer service department Contact the customer service
department Close appliance door
Check that the door has been closed properly. If the temperature does not
drop, contact the customer service department. Contact the customer service
department
19
Changing over door hinges GGPv 65.. / BGPv 84..
Door hinges should only be changed by a trained expert. Changing the door
hinges must be done by two people.
4. Remove the hinge components from the hinge bracket. Bearing ring Brass washer
1. Open door by about 90°.
Important note The door must be opened 90° before the lower hinge bracket is
removed.
This will hold the self-closing mechanism that is integrated into the door in
the required position for installation.
Hinge bushing
Plastic washer
Note on point 4 The hinge bushing with brass washer and bearing ring may stick
in the door mounting when you pull out the hinge bracket and, in this case,
must be removed from it.
WARNING!
If the door is removed and reinstalled in the closed position, this will lead
to destruction of the self-closing mechanism on the first opening of the door.
Important As a result of its heavy weight, the door must be held secure by one
person.
5. Transfer the upper hinge bracket and covers to the opposite side.
2. Remove hinge bracket. Pull the door out at the bottom and lift off.
3. Remove bearing ring from upper door mounting.
6. Unscrew base mounting bracket and attach on the other side.
20
7. Turn the door by 180°.
10. Fit the hinge components on the hinge bracket.
Bearing ring Brass washer Plastic washer
EN
8. Insert the bearing ring and hinge bushing in the upper door mounting.
11. Install the hinge bracket with the fitted hinge components in the lower door mounting.
9. Keeping door open at 90°, suspend in top square pin.
WARNING!
It is essential that the door is open at an angle of 90° during installation.
If the door is installed in the closed position, this will lead to destruction
of the self-closing mechanism on the first opening and closing of the door.
Important As a result of its heavy weight, the door must be held secure by one
person.
Note on point 11 The tabs on the bearing ring must fit into the recesses of
the door mounting during installation.
If necessary, gently rotate the upper ring.
12. Screw hinge bracket into place.
21
Liebherr-Hausgeräte GmbH Memminger Straße 77-79 88416 Ochsenhausen Germany home.liebherr.com
708515703
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>