TEKNOLINE T4-IS02 Indoor Station User Manual
- June 3, 2024
- TEKNOLINE
Table of Contents
TEKNOLINE T4-IS02 Indoor Station
Attentions
- Please keep devices away from strong magnetic field , high temperature , wet environment ;
- Please do not fall the devices to the ground or make them get hard impact;
- Please do not use wet cloth or volatile reagent to wipe the devices ;
- Please do not disassemble the devices.
Functions Overview
The indoor station is based on the protocol of TCP/IP, it is one of the main devices in digital video door phone system.
- Designed with 4.3 inch panel
- Support 24V non-standard POE power supply
- Support real time monitoring outdoor station
- Receive and send message from/to guard unit
- Support more than one indoor monitors in one house
- Support the video intercom between visitors and residents, residents and guard units
Product introduction
Product appearance
Interface description
Network interface : Support non-standard POE power supply Power input interface : DC 24 V
Parameters
Working voltage: DC 24V
Static current: ≤ 80 mA
Working current: ≤ 120 mA
LCD panel size: 4.3 inch
Resolution: 480 272
Dimension(L W D): 180 123 * 20.5 mm
Environmental temperature: -10℃~ + 55℃
Max Ring Duration: 30 seconds
Max Calling Duration: 120 seconds
Max Monitoring Duration: 30 seconds
Basic Functions
Menu
Call Record
Click call history and to check the record of the talking between the visitors
or the guard unit and the indoor station. Residents can check, read and delete
the talking records.
Information
Click messages and to check the information released by the community.
Configuration
Click setting and to enter the configuration interface, residents can
configure the language, time, check device information and to configuration
setting.
Standby
Click sleep and the indoor monitor will enter to the Standby status.
Call In
Steps: Doorbell rings Talk Open the door Talk Completed When the calling comes:
- Visitor calls the indoor monitor from outdoor station, the indoor station starts ringing.
- Resident can press button to talk with the visitor.
- During the conversation, resident can press button to open the door for the visitor. 5 seconds later after opening the door, the system returns to the standby status.
- Resident can press button to end up the talking.
Capture
- During the calling from the visitor, click the icon and capture manually.
- The captured pictures will be saved and can be found in the call records(only the last three captured pictures are saved if there’re more than three times of capture)
Volume adjustment:
- When visitors are calling, press to adjust the volume.
- Volume level from 1 to 5.
Monitoring
Open the door when monitoring
Steps: Choose the device to monitor Monitoring Unlock End
- Click the icon to monitor outdoor station. When there’re more than one outdoor stations, can press to switch over;
- During monitoring, the resident can press button to unlock for visitor;
- Click to talk, press again to end talking.
Capture when monitoring
During monitoring, click the icon on the screen to capture pictures manually.
Talk
Basic steps: Monitor Talk End
During monitoring(secondary outdoor station, outdoor station, perimeter gate
station),the resident can press button to talk.
Call Guard Center
When the device is at the standby status, press button to call guard unit.
Capture:
- During the calling from the visitor, click the icon and capture manually.
- The captured pictures will be saved and can be found in the call records (only the last three captured pictures are saved if there’re more than three times of capture).
Volume adjustment:
- When visitors are calling, press to adjust the volume.
- Volume level from 1 to 5.
Call records
Press button to enter the call records interface. Here you can check the call
records information.
Empty call records
Press button to empty call records.
Check call records
You can press or to choose, press to read the details of the information, and
to delete, to return.
Information
Press button to enter the text message interface. Here you can check the
community information sent from the guard center.
Empty information
Press button to empty information.
Check information
You can press or to choose, press to read the details of the information, and
to delete, to return.
System setting
Language setting
Click then choose language setting to enter the language setting.
For the first time of power on the station, language must be selected.
Time setting
Click to set the time. ( Inputing “1” in Auto-Sync blanket means “Yes”,
inputing “0” means”No”; inputing “1” in 12h blanket means to choose 12 hours
system, inputing “0” means to choose 24 hours system).
Configuration settings
Click button to choose configuration setting, input password to enter
configuration setting interface.
Room number setting
Click to enter the room number setting interface.
Factory reset
Choose to factory reset within 30s after powering.
Device Information
Click about,to the the interface. About interface shows the software version
and device setting information.
Installation
Suggested height
Installation instruction
-
Drive the screws on the bracket with the holes on the 86 box.
Fasten the screws to fix the bracket. -
After finishing the wiring of the indoor station, aim the slot behind the indoor station to the hook of the bracket.
After aiming correctly, move downward a little to make the indoor station well fastened on bracket.
Read User Manual Online (PDF format)