ZUSA-AP-41 Air Purifier Owner’s Manual

June 3, 2024
USA

ZUSA-AP-41 Air Purifier

IMPORTANT SAFETY INSTRUCTIONS

IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING SAFETY PRECAUTIONS: READ ALL INSTRUCTIONS BEFORE USING.

WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:

  • Unplug or disconnect the air purifier from the power supply if the plug is not working.
  • Warning – This appliance has a polarized plug (one blade is wider than the other). In order to fully fit it in the outlet, please reverse the plug. If it still does not fit, kindly contact a qualified electrician, do not attempt to modify this safety feature.
  • DO NOT touch the power plug with wet hands.
  • Turn off the power before cleaning the unit.
  • This is a 110v unit. Use it only with a 100v power supply in North America. Do NOT use it with a 220v power supply. This will seriously damage the unit and render the warranty void.
  • DO NOT take apart or modify the unit without authorization.
  • BEFORE USING THIS PRODUCT, PLEASE MAKE SURE TO REMOVE THE PLASTIC COVERING FROM ALL FILTERS

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid any type of hazard. This appliance can be used by children aged from 8 years and above and people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance of the unit shall not be made by children without supervision. Prior to cleaning or doing any type of maintenance, the appliance must be disconnected from the supply.

SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.

TECHNICAL DATA

  • Voltage: 120 V AC 60Hz
  • Power Rating: 26 W
  • Noise level: 55 dB(A)
  • Room size: up to 200 sq. ft.
  • Unit dimensions: 12.20”H x 8.26”W x 8.26”D
  • Unit weight: 5.3 lbs.

ZUSA-AP-41-Air-Purifier-FIG-1

BEFORE USE

INSTALLING THE AIR PURIFIERZUSA-AP-41-Air-Purifier-
FIG-2

Do not obstruct the air intake or the clean air outlet. To ensure enough ventilation, make sure there is a 20 inch (50 cm) distance between the air inlet and the wall or nearby furniture. This will ensure enough ventilation and high efficiency.

INSTALLING THE FILTER SET
All filters are combined into a one-piece housing for maximum effectiveness. Remove and replace the filter according to the instructions.

  1. Place the unit in a dry location and on a flat surface.
  2. Rotate the base clockwise.
  3. Rotate the base CLOCKWISE to remove the filter cover so you can change the filters. Remove the old filter and replace it with only GENUINE REPLACEMENT FILTERS.
  4. Reattach the base at the bottom of the unit (with the filters inside). Rotate the base counter-clockwise to secure it.

ATTENTION Remove all plastic packaging from the filter before installing. it. DO NOT run the air purifier if there is no filter installed. Please be careful when installing the back cover. Watch your hands.

  • To remove the base, turn it clockwise as shown in Figure A. To secure the base, rotate it counter-clockwise as shown in Figure B.

FILTER PURIFICATION

PRE FILTER
Removes larger particles including hair, fibers, dander, and others.

TRUE HEPA H13 FILTER
Removes 99.97% of particles down to 0.3 microns as well as PM2.5 particles such as smoke, pollen, dust mites and others.ZUSA-AP-41-Air-Purifier-
FIG-6

CONTROL PANEL

  • FAN SPEED BUTTONS
  • ON/OFF LIGHT BUTTON & FILTER CHANGE INDICATOR
  • POWER BUTTON

HOW TO USE

POWER BUTTON
Press the button once. The POWER indicator will turn on. After three seconds, the unit will start in Speed 1. The blue light will turn on.

FAN SPEED CONTROL
Press the button to select the speed from the following options: 1, 2, 3, S.

  • Speed 1 is slow
  • Speed 2 is medium
  • Speed 3 is fast
  • Speed “S” is sleep mode.

SLEEP MODE
Press the button for sleep mode. After 5 seconds, all lights will turn off and only the S button will show with partial lighting. Press any button to exit SLEEP mode.

STANDBY MODE
Insert the plug into a power source. Unit lights will turn on. After one second, the air purifier will run in standby mode.

TURNING OFF THE FILTER REPLACEMENT LIGHT
Press and hold the button until all lights are off. The button will show with partial light. Press again and hold until all lights turn on. Then, the filter replacement light should be off.

CLEANING AND MAINTENANCE

Disconnect the power plug before cleaning the unit. Do not put the unit in water or in any other liquid. Do not use abrasive, corrosive or flammable products to clean any parts of the unit. Filters cannot be washed.

CLEANING THE AIR PURIFIER
Clean the air purifier regularly. Use a soft and dry cloth to remove the dust from the air purifier. Use a soft and dry cloth to clean the outlet and inlet of the air purifier.

FILTER REPLACEMENT

LIGHT INDICATOR TO REPLACE THE FILTER
The unit will remind the user when the filter needs to be replaced. To know how to replace the filters, go to pages 4-5. Filters should be replaced every 2,500 hours of use. The filter indicator light will let you know when you have reached that time.