Burnham ALTAC Series Combi Gas Boiler
UNMATCHED SIMPLICITY
- No-touch combustion setup, engineered for a five-minute start-up
- Self-diagnostic boiler control
- Rate-based temperature reset, no outdoor sensor required –assesses environmental conditions, continually adjusting boiler operation for comfort and efficiency and long boiler life
- Three-side unobstructed service access – fast removal of front and side panels
- Simple 2-step natural gas-to-LP conversion with no kits or additional parts required
- Easy lift, wall hanging design (floor stand optional)
- Alta FastPipe (primary/secondary piping) included on combi models
NEXT-GENERATION ADAPTIVE COMBUSTION
- Continuous high-efficiency combustion without manual throttle or offset adjustments
- Low gas pressure capability (2.5 in. wc gas, 8.0 in. wc LP)
- Automatic self-calibration adjusts to variables in the environment, component wear, gas & vent pressure
HIGH-PERFORMANCE COMBI MODELS
- The world’s first 10:1, gas adaptive combi boiler – conserves fuel and extends boiler life
- Virtually instantaneous DHW response time
- Selectable economy or comfort/recirculation modes
- DHW temperature maintained under all demand conditions
- Integrated DHW hydro block with quick-disconnect flat plate DHW heat exchanger, boiler circulator, 3-way valve, and instantaneous DHW flow sensor
INDUSTRY-LEADING VALUE
- 5-year parts warranty, 12-year limited warranty on heat exchanger
- Universal vent connection for CPVC, polypropylene
- Boiler flow safety switch (UL353)
- 95% AFUE
Overview Component
Alta heating-only models (service view)
Near Boiler Piping
AltaFastPipe (primary/secondary header) is included with Alta combi boilers.
This single-piece copper component includes a temperature/pressure gauge and
1-1/4” supply/return connections.
Technical Information
Standard Equipment – All Models
-
Direct vent, high turndown, sealed combustion appliance
-
Altitude capability to 10,100 ft. (“G00” suffix)
-
Stainless steel 316L heat exchanger, corrosion resistant
-
Alta Control System
- Automatic “no-touch” combustion management
- Built-in self-diagnostics
- 2 inputs (T-stat, DHW)
- Warm weather shutdown
- Two-step LP conversion at gas valve switch and display – no kit purchase required
- Sensor-less, rate-based reset
- Fuse-protected, spare fuses provided
- Separated high and low-voltage connections
-
Boiler flow safety switch (UL353)
-
Low gas pressure capability;
Min: 2.5 in. WC (nat gas), 8.0 in. wc (LP gas) -
Three-side, unobstructed service access jacket
-
Vent connection for CPVC/PVC, polypropylene
-
Pre-installed hanging bracket and wall mount kit
-
Circulator
- Grundfos 26-99 (heating-only models)
- Grundfos UPS-78 Special (combi models)
Combi Models
- Integrated hydro block system with flat plate heat exchanger, boiler circulator, and 3-way valve
- AltaFastPipe (pre-made primary/secondary manifold)
Ratings & Specifications
Ratings & Specifications
Model
|
AFUE
%
| Heating Input (MBH)
min- max
| DOE
Heating Capacity (MBH)
|
Net AHRI (MBH)
| DHW Rates|
Vent Size (In.)
|
Boiler Wt. (lbs.)
at 70° TR (GPM)| at 77° TR (GPM)| Input (MBH)
min- max
ALTAC-136| 95.0| 13.6-120| 112| 97| 3.7| 3.4| 13.6-136| 2| 95
ALTAC-200| 95.0| 20-150| 141| 123| 5.2| 4.7| 20.0-200| 2| 116
ALTA-120| 95.0| 13.6-120| 112| 97| —| —| —| 2| 76
ALTA-150| 95.0| 20-150| 141| 123| —| —| —| 2| 103
ALTA-180| 95.0| 20-180| 169| 147| —| —| —| 2| 103
Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent operation, extensive piping systems, etc.
Safety Relief Valve Pressure, Water – 30 PSI std. ASME certified “H”. Maximum Allowable Working Pressure at 50 PSI. Max allowable temperature setting 210ºF. The target setpoint is 180°F, manual reset high limit setpoint is 210°F. Boilers shipped set for natural gas. Boiler SKUs with the “G00” suffix may be installed and set for altitudes up to 10,100 ft.
Boiler Depth
Boiler Depth
Model
| “A”
(Inches)
ALTAC-136| 16.3
ALTAC-200| 20.4
ALTA-120| 16.3
ALTA-150| 20.4
ALTA-180| 20.4
Accessories
- Floor stand kit (P/N: 111576-01)
- Service part kit (P/N 111419-01)
- Kit, CPVC starter and PVC vent terminations: (2” P/N: 107039-01)
- LP altitude electrode – ALTA-150, 180, 200 only: (P/N 111745-01)
Typical Venting Configurations
(Horizontal and Vertical)
Illustrations are for representation only. For complete venting information,
please see Installation, Operating and Service Instructions.
www.usboiler.net
©2022 U.S. Boiler Company, Inc. Lancaster, PA
Phone: 1-888-432-8887